MEAN WELL LCM-40TW Series 40W Constant Power Mode With Tunable White LED Driver Instruction Manual
- June 10, 2024
- MEAN WELL
Table of Contents
- MEAN WELL LCM-40TW Series 40W Constant Power Mode With Tunable White LED
- Features
- Applications
- Description
- Model Encoding
- SPECIFICATION
- BLOCK DIAGRAM
- DRIVING METHODS OF LED MODULE
- DIP SWITCH TABLE
- DIMMING OPERATION
- OUTPUT LOAD vs TEMPERATURE
- STATIC CHARACTERISTIC
- TOTAL HARMONIC DISTORTION (THD)
- POWER FACTOR (PF) CHARACTERISTIC
- EFFICIENCY vs LOAD
- MECHANICAL SPECIFICATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL LCM-40TW Series 40W Constant Power Mode With Tunable White LED
Driver Instruction Manual
LCM-40TW series
Features
- Available for DALI device type 6(DT6) and device type 8(DT8) Tunable White control
- Constant power mode output with 2 channels
- Plastic housing with class Il design
- Built-in active PFC function
- Standby power consumption KO.5W
- Minimum dimming level 0.2%
- Cooling by free air convection
- 5 years warranty
Applications
- Tunable White Lighting
- Downlight
- Panel Light
- Decorative Light
- Industrial lighting
- DALI Building automation
Description
LCM-40TW Series is a 40W constant power output LED driver with two channels output for Tunable white function. It can operate from 180–277 V AC and output current ranging between 500 mA to 1050 mA selectable by dip switch. Thanks to high efficiency up to 87%, it is able to operate for -300C •50C case temperature under free air convection. LCM-40TW is designed based on DALI-2 D T 8 Tunable white function and is also usable as two independent output channels with D T 6 applications. LCM-40TW can be adjusted for light intensity and color temperature by a push button as a simple way dimming, so it provides the optimal design flexibility for LED Lighting luminaires.
Model Encoding
SPECIFICATION
NOTE
-
All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25C of ambient temperature.
-
De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
-
Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
-
Efficiency is measured at 800mA50V output set by DIP switch
-
Current ripple is measured 500/0-1000/0 of maximum voltage under rated power delivery.
-
Standby power consumption is measured at 180-230VAC.
-
The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. -
The ambient temperature derating of 3.5C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft).
-
Based on IEC 62386-101/102 DALI power on timing and interruption regulations, the set up time needs to test with a DALI controller which can support for DALI power on function, otherwise the start up time will be higher than 0.5 second.
-
For more information, please contact with MEAN WELL sales.
X Product Liability Disclaimer : For detailed information, please refer to https://wmv.meanwell.com/serviceDisclaimer.aspx
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULE
DIP SWITCH TABLE
LCM-40TW is a multiple-stage constant power driver, selection of output current through DIP switch is exhibited below.
DIMMING OPERATION
※PUSH dimming (primary side)
- The factory default dimming level is at 100%.
- If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver.
- Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button.
- The maximum length of the cable from the push button to the last driver is 20 meters.
- The additive push button can be connected only between the PUSH terminal, as displayed in the diagram, and AC/L (in brown or black); it will lead to short circuit if it is connected to AC/N.
Function
※DALI interface(primary side; for DA2-Type)
- Apply DALI signal between DA+ and DALCM
- DALI protocol comprises 16 groups and 64 addresses.
- First step is fixed at 0.2%.
DALI Dimming curve
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
POWER FACTOR (PF) CHARACTERISTIC
EFFICIENCY vs LOAD
MECHANICAL SPECIFICATION
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>