Product Information

The Ethernet LED Tower Light is a visual signaling device that can be used to indicate the status of a process, machine, or system. The product comes in two models – QT50(M)L/ QT70(M)L-ETN and is available in different colors (red, amber, green, blue, and white) and mounting options (LB18, LW18, QZ18, SZ18, QL18, SL18, QLA18, LB24, LW24, QZ24, SZ24, QL24, SL24, QLA24). The device has a noise level of 90dB or 85dB depending on the model and is CE compliant at DC24V.

Product Usage Instructions

Before installing and operating the product, please read the user manual carefully to ensure safe and correct use. Follow the precautions for safety and correct use provided in the manual to avoid any damage to property, malfunction of the product, or loss of life or serious physical injury.

Precautions for Safety

  • During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
  • Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection.

Ordering Specifications

The product can be ordered by specifying the model number (QT50L-ETN-WS or QT70L-ETN-WS), layer (1-5), voltage (DC12V or DC24V), color (R-Red, A-Amber, G-Green, B-Blue, or W-White), and mounting option (LB18, LW18, QZ18, SZ18, QL18, SL18, QLA18, LB24, LW24, QZ24, SZ24, QL24, SL24, QLA24).

Product Specifications

| QT50L-ETN| QT50ML-ETN| QT70L-ETN| QT70ML-ETN
---|---|---|---|---
Voltage| DC12V DC24V| DC12V DC24V| DC12V DC24V| DC12V DC24V
Current| 0.210A 0.110A| 0.280A 0.150A 0.350A 0.190A| 0.290A 0.160A| 0.370A 0.210A
Certificate| CE compliant : DC24V| R-Red| R-Red G-Green| R-Red A-Amber G-Green B-Blue

Dimensions

The dimensions of the product vary depending on the model and layer. Please refer to the user manual for more information.

Wiring Instructions

The product can be wired using DC/AC power supply. Connect the white and black wires to the power supply and the RJ45 LAN connector to the Ethernet network. Ensure that a fuse is used. Please refer to the user manual for more information.

Product Installation

To test the Ethernet LED Tower Light, connect the LAN cable to the router so that the tower light can access the Ethernet network. Ensure that the power supply meets the product specification. To apply the Ethernet device, activate default PC network only and run Windows CMD(Command line) of PC over the same network in order to confirm network information where the Ethernet product will be connected.

Thank you for purchasing Qlight’s products. Please read this user manual carefully prior to installation and operation to ensure safe and correct use.

Precautions for Safety

Failure to follow the instructions below may cause a loss of life or serious physical injury.

  1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
  2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury, malfunction or damage to the product.)
  3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
  4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
  5.  When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to follow this may cause damage to property, fire, electric shock and loss of life.)

Precautions for Correct Use

Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product that would void the warranty.

  1. Please remove any objects that can interrupt ventilation around the product.
  2. Please turn off the power of the product immediately if it fails to operate properly.
  3.  Carefully wire the product according to each product’s specification.
  4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
  5. Do not apply excessive force/impact to the product.
  6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.

Ordering Specifications

QT50(M)L-ETN

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-2

QT70(M)L-ETN

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-3

Product Specifications

QT50(M)L-ETN

Model number Layer Voltage Current Certificate Color
  1 DC12V DC24V 0.210A

0.110A

| ****







| ****

R-Red

 | 2| DC12V DC24V| 0.280A

0.150A

| R-Red G-Green



QT50L-ETN

| ****

3

| DC12V DC24V| 0.350A

0.190A

| R-Red

A-Amber G-Green

 |  |  | R-Red
QT50ML-ETN| 4| DC12V DC24V| 0.420A

0.230A

| A-Amber G-Green
 |  |  |  | B-Blue
 |  |  |  | R-Red
 | ****

5

| DC12V DC24V| 0.490A

0.270A

| A-Amber G-Green

B-Blue

 |  |  |  | W-White

QT70(M)L-ETN

Model number Layer Voltage Current Certificate Color
  1 DC12V DC24V 0.210A

0.110A

| ****








| ****

R-Red

 | 2| DC12V DC24V| 0.290A

0.160A

| R-Red G-Green



QT70L-ETN

| ****

3

| DC12V DC24V| 0.370A

0.210A

| R-Red

A-Amber G-Green

 |  |  | R-Red
QT70ML-ETN| 4| DC12V DC24V| 0.450A

0.260A

| A-Amber G-Green
 |  |  |  | B-Blue
 |  |  |  | R-Red
 | ****

5

| DC12V DC24V| 0.530A

0.310A

| A-Amber G-Green

B-Blue

 |  |  |  | W-White

  • CE compliant : DC24V
  • Protection rating : IP54
  • Ambient operating temperature : -30°C to + 50°C

Dimensions

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-4
Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-5

Wiring Instructions

  • Connect RJ45 connector that is connected to UTP cable to Ethernet port of a PC or a router.
  • External power line – UL1015 AWG18(0.75sq) x 2C 400mm
  •  For AC type, power cable is equipped with the product.
  • UTP Cable: Category 5 cable

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-6

Product Installation

Test Ethernet LED Tower Light

  1. Please connect LAN cable of the tower light to the router so that the tower light can access Ethernet network by referring left diagram.
  2. Please be sure that the power supply shall meet the product specification accordingly

Installation wiring instructions

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-7

Applying the Ethernet Device

  1. Please activate default PC network only. Please run Windows CMD(Command line) of PC over the same network in order to confirm
    network information where the Ethernet product will be connected.
    Example) Windows 7 : Start(Run)->CMD->ipconfig /all
    Windows 10 : Start menu-> Click right mouse button->CMD->ipconfig /all

    • Please refer to below network information when the Ethernet product’s network environment is configured.

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-8

  1. Because the ETN tower light is connected to a hub with the PC that is same as the picture on the front page, ETN tower light and the PC are now connected with the same network.
  2. Please download the product manual, library file and test program from Qlight website(www.qlight.com) or blog.qlight.com

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-9

  1. When you unzip the file, there will be a file with the same name below. The instructions are listed inside the file.
  2. When you unzip “ETN TEST PROGRAM.zip” file, following folders are created.

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-10

  1. Run the “Mac_Setting.exe” program that is inside the IP Set Program Folder .

  2. When the program is running such as the right figure, click the “Mac Find” button in the “Find Mac Address / Select” section MAC Address of the connected device appears when you click the Device List combo box. (If the Mac Addr does not appear, make sure that the connection status or the power supply is functional and then retry.)

  3. Select the MAC Addr of the device you want to change, and then click on the “Read” button.

  4. Check the information and settings from the “Mac config status”

  5. Set the value of users network information identified in the previous chapter (subnet mask, gateway) in each text box, and set a different IP_Addr than your PC
    Apply the settings by pressing the Write button

  * The port is set to “20000“by default and the port number can be changed if necessary
  * Reconnect After Disconnecting the power from the tower light.
  1. ETN Test Program Files folder includes the followings

  2. Run the “QLight_Lamptest_TCP” program.
    Article| Detailed specification
    ---|---
    ① Network information setting| – Input port on TCP/PORT and IP address on TCP/IP that set on Ethernet tower lights

② Lamp control

| –  ON : Click the button Lamp ON

–  ON/OFF : Click the button Lamp Flash

–  OFF : Click the button Lamp OFF

③ Sound group selection

| –  WS : 5 warning sounds(mono)

–  WP : 5 special warning sounds(mono)

–  WM(1) : 5 Melodies(mono)

–  WA(1) : 5 alarms(mono)

–  WB : Software Buzzer 5 sounds(speaker type)

–  Buzzer : 5 Buzzer sounds

④ Sound selection| – Select 5 sounds based on model which is fixed on Ordering Specifications

  • User can select appropriate sound pattern by referring Ordering Specifications. There’re WS, WM, and WA sound patterns and user can choose the option when placing order.

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-13

  • Fill TCP/IP and TCP/PORT (①Network Information Setting) with IP address and port that has been setted in ethernet tower light.
  • When click LAMP ON, correspond lamp turns on.
  • When click LAMP OFF, correspond lamp turns off.
  • Please choose appropriate sound pattern group by referring ③ Sound Group Selection area.
  • You can choose sound pattern by referring ④ Sound Selection.
  • Tower lamp plays sound when SOUND button is pressed.
  • Tower lamp stops sound when SOUND OFF button is pressed.

Parts Definition

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-14

How to replace the module / Light Function Selection

How to replace the module

  • Disassembling the module
1. Twist the upper module kit in a counterclockwise direction so the “I” mark from both kits align.
2. Disassemble by removing the upper module kit from the lower one.
  • How to disassemble the connector
    Disassemble the connector of the upper lens and the connector of the lower lens in the direction of the arrow.

  • How to assemble the connector
    Assemble the connector of the upper lens and the connector of the lower lens in the direction of the arrow.

  • Assembling the module

1. Put the two module together by aligning the upper module’ “I” mark and the lower module’ “I” mark together.
2. Lock the two kits by twisting the upper module kit in a clock wise direction so the upper module’ “◁” mark aligns with the lower module’ “I” mark.

Light function selection

  • Please refer to the instruction below to use light function selection switch(①) located inside the product.
  • Default function is set at steady LED. Select the desired function for your application during installation.

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-19

Mounting Hole Specifications

  1. Machine holes on the mounting surface referring to the diagram below.

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-20

  1. Remove the flange nuts from bolts and place the product through the mounting surface holes.
  2. Fasten the flange nuts on the opposite side of the mounting surface until the product is tightened securely.

Mounting Accessories (Sold Separately)

Please refer to the dimensions below for installati on of mounting brackets

QT50ML-ETN/ QT70ML-ETN -Direct Mounting Type Model

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-21

QT50L-ETN – Pole Mounting Type Model

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-22
Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-23

QT70L-ETN – Pole Mounting Type Model

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-24 Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-25

Technical Certification

Qlight products are designed to meet strict quality and technical standards. Thus, the Qlight brand is widely recognized for its high quality
and technical innovations from leading institutions around the world.

Qlight-QT50\(M\)L-Ethernet-LED-Tower-Light-fig-27

ABOUT COMPANY

  • Qlight Co., Ltd. www.qlight.com | trade@qlight.com

    • Head Office | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
    • Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
    • Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
    • Qlight OverSEAs Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
    • Qlight Public Relations & Marketing Team Office | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
  • Qlight USA, Inc. www.qlight.com www.qlightusa.com | sales@qlightusa.com
    3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 – 408 – 519 – 5740 Fax. +1 – 408 – 519 – 5739

  • SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | qlightcn@qlight.com

    • China Factory/ Shanghai Sales Office | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86 – 21 – 6651 – 7100 Fax. +86 – 21 – 6315 – 3929
    • China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China Tel +86- 513- 8384- 9999 Fax +86- 513- 8384- 9910

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals