Thank you for purchasing Qlight’s products. Please read this user manual carefully prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
- During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
- Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury, malfunction or damage to the product.)
- Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
- Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
- When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to follow this may cause damage to property, fire, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product that would void the warranty.C
- Please remove any objects that can interrupt ventilation around the product.
- Please turn off the power of the product immediately if it fails to operate properly.
- Carefully wire the product according to each product’s specification.
- Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
- Do not apply excessive force/impact to the product.
- Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Ordering Specifications
Product Specifications
Model number
|
Voltage
|
Current
| Bulb specifications|
Sound pattern and volume
|
Certificate
|
Weight
|
Color
---|---|---|---|---|---|---|---
Volts/ Watts| Configuration| Part#
SED SEDP
| DC12V| 3.755A| 12V15W| G23 15S| 17| • WS-5 Warning Sounds : Max.118dB
• WP-Special warning sounds
: Max.118dB
• WM-5 Melodies : Max.118dB
• WA-5 Alarms : Max.116dB
• WV-5 Customizable sounds
: Max.113dB
|
|
• SED
DC-3.17kg, AC-3.94kg
• SEDP
DC-3.42kg, AC-4.19kg
|
R-Red
A-Amber G-Green B-Blue
DC24V| 1.788A| 24V15W| G23 15S| 18
AC110V| 0.422A| 12V15W| G23 15S| 17
AC220V| 0.211A| 12V15W| G23 15S| 17
SD SDP
| DC12V| 3.755A| 12V15W| G23 15S| 17|
|
• SD
DC-3.43kg, AC-4.21kg
• SDP
DC-3.72kg, AC-4.50kg
DC24V| 1.788A| 24V15W| G23 15S| 18
AC110V| 0.422A| 12V15W| G23 15S| 17
AC220V| 0.211A| 12V15W| G23 15S| 17
SMD SMDP
| DC12V| 3.644A| 12V15W| G23 15S| 17| • WS-5 Warning Sounds : Max.120dB
• WP-Special warning sounds
: Max.120dB
• WM-5 Melodies : Max.120dB
• WA-5 Alarms : Max.118dB
• WV-5 Customizable sounds : Max.115dB
|
–
|
• SMD
DC-5.98kg, AC-6.76kg
• SMDP
DC-6.27kg, AC-7.05kg
DC24V| 1.822A| 24V15W| G23 15S| 18
AC110V| 0.448A| 12V15W| G23 15S| 17
AC220V| 0.224A| 12V15W| G23 15S| 17
CE compliant : DC24V
- Protection rating : IP66
- Ambient operating temperature : -20°C to +50°C
Dimensions
(Units : mm)
Sound Selection – Using Internal Switch (Built-in Sound Type)
- Standard unit has 5 built-in sound tones. Select different built-in sounds using the sound setting switch.
- For standard type, once the unit is powered on, light and sound are working simultaneously.
Sound Type by Group
Category | Sound pattern | Channel | Sound tone | Volume (Max.) |
---|---|---|---|---|
SED/ SEDP/ SD/ SDP | SMD/ SMDP |
WS
| ****
5 Warning sounds
| Ch1| Fire.A-ANG| ****
118dB
| ****
120dB
Ch2| Emergency WA-U
Ch3| Ambulance PI-PO
Ch4| Machinery Fault
Ch5| High Expansion
WP
| ****
5 Special Warning sounds
| Ch1| Fire.A-ANG| ****
118dB
| ****
120dB
Ch2| Abandon Alarm
Ch3| Machinery Fault
Ch4| High Expansion
Ch5| 7 Short PI. / 1 Long
WM
| ****
5 Melodies
| Ch1| Sweet Home| ****
118dB
| ****
120dB
Ch2| For Elise
Ch3| Cuckoo’s Waltz
Ch4| Piano Sonata
Ch5| Turkish March
WA
| ****
5 Alarms
| Ch1| Beep Intermittent| ****
116dB
| ****
118dB
Ch2| Door Chime
Ch3| Phone Ring
Ch4| PI.PI.PI Short
Ch5| Tripping Beat
WV| 5 Customizable sounds| Ch1-Ch5| Available upon request
(customized voice type)
| 113dB| 115dB
Wiring Instructions for LC Type
LC type product with exposed sound selection signal line is avali-able uapon request. Please refer to the diagram below for wiring.
- External power line – UL1015 AWG18(0.75sq) x 2C 400mm
- External signal line – UL1007 AWG22(0.3sq) 400mm
Volume Adjustment
Volume Dial
- The volume output of this product is adjustable.
- Turn the volume dial clockwise to increase the volume, and turn counterclockwise to decrease the volume.
- There will be no sound when the dial is put at MIN.
Terminal Box Wiring Instructions
- Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper body to get rid of the upper lighting element of the unit.
- Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the wire for secure connection.
- Please wire the power line to terminal ①
- For AC-type products, wire regardless of polarity.
- For DC-type products, wire terminal of black line to (-) polarity.
Parts Definition/ Installation
Parts Definition
Installation
- First, machine taps or holes on the mounting surface.
- The mounting hole of this product is 8mm(SED/SEDP, SD/SDP only), 11mm(SMD/ SMDP only)mm in diameter(hole).
- When machining taps, fasten the bolt through the mounting hole of the product.
- When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.
- When assembling using bolt and nut, please make sure to use flat washer and spring washer.
Mounting Hole Specifications
- Machine holes on the mounting surface referring to the diagram below.
Bulb Replacement lnstructions
- Please wait at least 1 minute after turning off the power before replacing the bulb.
- In order to dissemble the bulb, please push down the bulb(①) lightly and screw it counterclockwise.
- In order to put the bulb in to the unit, please place the bulb(①) in the socket(②) and screw it clockwise while lightly pushing down the bulb.
Precautions for installation
- In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-down positions where water can potentially penetrate into the product and impact it’s operation.
Installation Environment and Protection Rating
- This product is designed for use with protection rating of IP66.
- If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating indicated(IP66), it may cause malfunction or damage to the product.
- For further information, please visit our website (www.qlight.com).
Technical Certification
Qlight products are designed to meet strict quality and technical standards. Thus, the Qlight brand is widely recognized for its high quality and technical innovations from leading institutions around the world.
For your safety
Specification and dimensions listed in this catalogue subject to change
without notice for product quality improvement. The newest product information
is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before
installation and use.
Qlight Co., Ltd. www.qlight.com |
trade@qlight.com
Head Office | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu,
Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo,
Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111) Qlight OverSEAs Sales
Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel :
+82-51-620-4100
Qlight Public Relations & Marketing Team Office | 704 Nakdong-daero, Sasang-
gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
Qlight USA, Inc. www.qlight.com
www.qlightusa.com |
sales@qlightusa.com
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 – 408 –
519 – 5740 Fax. +1 – 408 – 519 – 5739
SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com
www.qlightcn.com |
qlightcn@qlight.com
China Factory/ Shanghai Sales Office | #19, Nanda Road, Baoshan Area,
Shanghai, China Tel. +86 – 21 – 6651 – 7100 Fax. +86 – 21 – 6315 – 3929 China
Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial
Development Zone, Qidong, Jiangsu Province, China
Tel +86- 513- 8384- 9999 Fax +86- 513- 8384- 9910
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model
name, symptom, telephone number and address.
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT
NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu,
Seoul, Korea (Postal Code : 08507) Factory : 185-25, Mukbang-Ro, Sangdong-
Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805)
www.qlight.com
References
- Qlight - Warning Light, Beacon, Audible & Visual Signal, Tower Light
- 可莱特(Qlighte)_专注多层信号灯、声光报警器,防爆警示灯,机床照明灯等产品的生产和销售
- Signal Tower Lights, Warning Lights & Electric Horns, Fully Enclosed Products, Explosion proof Products, LED Work Lights-Qlight
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>