GE Lighting PC93130603 Smart Dimmer 4 Wire Switches Installation Guide
- June 10, 2024
- GE Lighting
Table of Contents
- GE Lighting PC93130603 Smart Dimmer 4 Wire Switches
- Product Information
- Product Usage Instructions
- Simple DIV Set Up
- Let’s Do It
- Turn Off The Power!
- Remove Your Old Switch
- Connect The Wires
- Fit Wires Into Wall Box
- Secure The Switch
- Turn The Power Back On
- Additional Information and Warnings
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GE Lighting PC93130603 Smart Dimmer 4 Wire Switches
Product Information
The product complies with part 15 of FCC rules and Industry Canada licence- exempt RSS standard(s). It is designed to operate without causing any interference and must accept any interference that may cause undesired operation of the device.
Product Usage Instructions
- Ensure that the device is placed in an area that is free from interference from other electronic devices.
- Turn on the device and follow the manufacturer’s instructions for use.
- If the device experiences interference, it must be moved to an area with less interference or the interfering device must be turned off.
- If the device causes interference with other electronic devices, it must be turned off or moved to an area where it will not cause interference.
- Always follow the manufacturer’s instructions for proper use and maintenance of the device to ensure its proper functioning.
WARNING: RISK OF ELECTRIC SHOCK This product installation requires handling 120 volt wiring. Follow each step carefully. If any concerns handling wiring, hire a qualified electrician. Ensure all work meets applicable local and national codes.
Simple DIV Set Up
Compatibility Requirements
- Rating 120V AC 60Hz Neutral wire is required (Wire is usually white or grey)
- Ground wire is required (Wire is usually green, green with a yellow stripe, or copper) ©
- Wi-Fi 802.11 b/g/n @ 2.4 GHZ is required
- Works with halogen, incandescent and LED bulbs, including Cync smart bulbs. For a list of compatible dimmable bulbs, visit gelighting.com/compatibility
- Max LED rating 1.25 amps / 150W
- Max incandescent/halogen rating 5 amps / 450W
IMPORTANT NOTE ON 3-WAY WIRING:
Some lights have one wall switch, while others are controlled by two or more
wal switches (such as stair lights, which have a switch at both the top and
bottom of the stairs). If your lights have more than one switch (called a
3-way), we’ve created instructions for how to install and enable the
capability. 3-way control requires 2 CYNC wired switches or I wired and wire-
free. Visit cyncsupport.gelighting.com for 3-way installation instructions and
how-to videos.
Note: Complete set up in the CYNC App to enable 3-way/multi- way functionality.
GE is a trademark of General Electric Company. Used under trademark license. Amazon, Alexa, and all related logos are trademarks of Amazon.com, Inc. or its affiliates. Google and other related marks and logos are trademarks of Google LLC.
Let’s Do It
Included:
You’ll need:
Approximately 30 minutes of your day to install and set up the switch
You Got This! And we’re here to help. For in-depth instructional videos and a guided tour through the installation, go to: cyncsupport.gelighting.com or call 1-844-302-2943 Scan here for videos & guided installation steps.
BEFORE YO U DO ANYTHING:
Turn Off The Power!
- Turn off the power for the switch location at the circuit breaker box.
- Test existing switch by toggling switch on/off, ensuring lights do not turn on.
- Now, follow these setup steps for a single gang switch.
Remove Your Old Switch
- Remove the existing wall plate and switch from the wall.
- Use voltage tester on the black wires to confirm power to the switch is off (recommended).
- Before disconnecting the wires from the wall, label each with the provided wire labels.
- Neutral and ground wires are required. If you don’t have either wire, the Cync switch is not compatible.
- Disconnect wires and remove existing switch.
Connect The Wires
-
Connect the neutral (white) wire on the switch to the neutral (white label) wire from the wall.
-
Connect the black line wire from the switch to the line (black label) wire from the wall.
-
Connect the load red wire from the switch with the load (red label) from the wall.
-
Connect the ground (green) wire on the switch with the ground (green label) wire from the wall.
-
Cap the 3-way/multi-way traveler wire (if applicable).
For 3-way switch setup, visit cyncsupport.gelighting.com -
Attention: Incorrectly connecting the Neutral or Ground wire from the wall to the Line or Load wire on the switch will damage the product.
Fit Wires Into Wall Box
Neatly push the wires back into the box, rotating the switch so it’s oriented according to the image .
Secure The Switch
- Using a Phillips screwdriver and the screws provided, secure the switch to the wall until level and flush.
- Screw on the wall plate bracket, then snap the wall plate cover onto the bracket.
Turn The Power Back On
After the switch is secured and wall plate mounted, turn the power back on at
the circuit breaker box. At the switch, the light ring will flash blue
indicating the device is wired correctly and the device is in setup mode.
Light ring will continuously flash blue until the switch is added to the Cync
App.
Light ring will not illuminate if wired incorrectly.
IF LIGHTS DON’T TURN ON:
- Check that air gap switch is depressed.
- Check that power to the switch is on at the breaker.
- Turn power off at the breaker, return to the switch to confirm the wires are securely and properly wired according to the installation guide.
- Go to cyncsupport.gelighting.com for more troubleshooting.
Congratulations!
You’ve completed the Smart Switch installation.
Next. ..
Enable Your Voice Assistant
Connect to your Amazon Alexa or Hey Google voice assistants
in the CYNC App.
Then try this …
Alexa, turn off the living room.
Alexa, turn on the bedroom.
Alexa, set kitchen to 50%
Hey Google, turn on the lights.
Hey Google, good morning.
Hey Google, I’m leaving.
Additional Information and Warnings
FCC Compliance Statement Compliance Notice:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there
is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Conned the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of FCC rules and Industry Canada licence-
exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
Changes or modifications that are not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
RF Exposure Information:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. In order to avoid the possibility of exceeding the
FCC radio frequency exposure limits, human proximity to the antenna shall not
be less than 8 inches during normal operation.
RF Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth
for an uncontrolled environment. This transmitter must be installed to provide
a separation distance of at least 8 inches from all persons and must not be
collocated or operating in conjunction with any other antenna or transmitter.
Caution (dimmer)
To reduce the risk of overheating and possible damage to other equipment, do
not install to control a receptacle or motor-operated appliance or
transformer-supplied appliance.
For supply connections, use copper wire only rated at 75″C.
Caution High Voltage
- Disconnect power supply before servicing
- Operation temperature: 0 to li0″C
- For Control of Electronic Ballast, CFLs, LED, and LED Lamps
- Type l Enclosure
- IP20
- Pollution Degree 2
- Impulse Volatge: 2500V
- Type l.B action
- Indoor use only
Like your new Smart Switch? Share your experience!
Leave a review where you purchased the product
FRONT
3.7583
Let’s illuminate what your smart switch can do:
-
CD Create the perfect lighting scene for every scenario.
Go to CYNC App and preset the optimal light levels under routines. -
Automate your lights to turn on when you come home.
Go to CVNC App and schedule times to turn lights on and off under routines. -
Preset brightness levels.
Dim switch to desired level, then turn off. Use Dim button instead of center on/off button to turn on lights at the preset level. -
Control other CYNC or C by GE bulbs in the room with your switch.
Go to CVNC App. Add bulbs and switches to the same room or group. (sold separately)
GE and C by GE are trademarks of General Eleclric Company. Ud under lrademark license.
BACK
3.7583
Touch Controls
Connect to your Alexa or Hey Google device to control your lights with your
voice.
Try these voice commands:
-
Amazon Alexa
Alexa, turn off the living room. Alexa, goad morning.
Alexa, set kitchen to 50%. -
Alexa, ban matin.
Alexa, regle la cuisine a 50 %. -
Hey Google
Hey Google, turn an the lights. Hey Google, set bedroom to 20%. Hey Google, I’m leaving.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>