Safety regulations and measures
- The electrical installation must be switched off during installation.
- Install the power-inlet according to the stated instructions and directions in the manual.
- Use cables with appropriate wire size.
- Connection and safety features must be executed according to the locally applicable regulations.
Things you need for installation
- Pencil
- Electric drill
- Hole saw
- 4,5 mm or 1/8 drill bit
- Small flat blade screwdriver
- 2,5 mm hexagonal socket wrench for the 4 mm screws
- Cutting/wire stripping pliers
Installation direction
To install the power-inlet proceed as follows:
- Make a cut out in ship’s hull using the outline drawing. Take note of size (A) and holes (C).
- Remove the rear safety enclosure from the inlet.
- Take out the electrical cable and insert it in the rubber covering.
- Peel for 50 cm. the end of the cable by pulling out the wires.
- Back off terminal screws on the rear housing of the inlet.
- Insert wires into the proper colour coded terminal openings (see table “SPECIFICATIONS” for the proper colour codes) on the back of the inlet. Tighten terminal screws to 1,6-2,2Nm (14-20 in.-lbs.) torque. Make certain there is no wire insulation under any terminal.
- Slide the rear safety enclosure onto the back of the inlet.
- Fix the socket to the hull with M4 screws.
SPECIFICATIONS
**** SPECIFICATIONS
→ Generat| Z20320 1 6
→ Connections:| 2p+ E
→ Voltage:| 250V
→ Maximum current (Am p):| 16A / 250V
→ Protection degree:| IP56 (IEC 529)
→ Marking:| CE in according to reg. EU 2014’35/EU and harmomsed standards used
ENIIEC 60309-1: 1999
→ Materials :|
→ Cap and bezel.| 316 Stainless steel
→ Contact blades/terminal parts·| N1cket plated brass
COLOUR CO,DES
Funclfon :| Wire colour :
Terra (ground)| Yellow/Green
N (Neutral)| Blue
L1 (phase. load)| Brown or black
WIRE SIZE
Voltage (Volts)| Current Amp| Cross section
2S0VAC| 16A| 2,5 mm2
WARNING:
THIS INLET IS INTENDED FOR BOATS WIRED FOR THE EUROPEAN MARKET.
RATING: 16A/250VAC (SOHz)
THE REQUIREMENTS FOR INSTALLATION OF ELECTRICAL SYSTEMS
ON CRAFT OF HULL LENGTH U·P TO 24M ARE SPECIFIED IN THE
ISO 13297 STANDARD