ELECTRA VPE.0BF03.ELB(W)TL Touch Line Video Intercom User Manual

September 20, 2024
Electra

ELECTRA VPE.0BF03.ELB(W)TL Touch Line Video Intercom

Product Information

Specifications:

  • Dimensions & Weight:
    • VPE.0BF03.ELB(W)TL: 354 x 127 x 42 mm / 2.1 kg
    • VPE.0BS03.ELB(W)TL: 341 x 113 x 36 mm / 1.9 kg
  • Material: Aluminium-Case + Secured Glass
  • IP Rating: IP44
  • Operating Temperature: -30°C to +80°C
  • Camera: CMOS 1.3, 800 TVL video camera with RFID card access
  • Operating Voltage: 11 to 14 Vd.c.
  • Stand-by Current: 60 mAd.c. (Summer), 130 mAd.c. (Winter)
  • Operating Current: 220 mAd.c. (Summer), 300 mAd.c. (Winter)

Product Usage Instructions

  • Safety Instructions:
    Ensure to follow the safety instructions provided in the manual for proper installation and usage of the video outdoor panels.

  • Warranty Information:
    A 24-month warranty is provided for non-conformity and/or hidden defects based on the purchase document. The warranty does not cover incorrect installation, breakage, theft, fire, floods, or RFID access cards.

  • Cables and Installation:
    Refer to the provided connection diagrams for proper installation of cables and connections. Use UTP/FTP cat5e or cat6 cables for connections within the specified range.

  • Connection Diagrams:
    Follow the connection diagrams provided in the manual for connecting the outdoor panel to the central unit using the specified cables and optional RJ45 connections.

FAQ:

  • Q: What is the warranty coverage for the video outdoor panels?
    A: The warranty covers non-conformity and hidden defects for 24 months based on the purchase document.

  • Q: What should I do in case of incorrect installation?
    A: Warranty is not applicable for incorrect installations; ensure to follow the installation guidelines provided in the manual for proper setup.

Specifications

Warranty

  1. A 24-month warranty is granted, according to the existing legislation, based on the purchase document.
  2. Warranty is granted for non-conformity and/or hidden defects.
  3. Warranty is NOT granted for: incorrect installation and/ or operation, non-compliant with this manual; broken glass, blows, mechanical shocks; theft, fire, floods, natural disasters; unprotected products during renovation activities; the RFID access cards (tags), which are considered consumables.

Safety instructions

Cables and installation

Connection diagrams

Installation

Orientation of the video panel camera

Mounting on the wall – Surface panel

Mounting on the wall – Flush panel

Mounting on the wall – Flush panel

smart 4.3″ VIDEO terminal

smart/extra 7″ VIDEO terminal

Connection box – 4 outputs

Connection box – 4 outputs

Programming

Programming mode enabling
Long press the PROG button at SCU to enter the programming mode →The red LED turns on.

Video outdoor panel

Step 1
Long touch the key at the panel →The panel confirms with a long BEEP. The display shows:

Step 2
Enter the producer’s PIN code (0000) →The panel confirms with a long BEEP. The display shows the following MENU:

  • Change PIN – programming a new, personalized PIN code
  • Add new tag – programming the RFID access CARDs/ TAGs
  • Change address – programming the addresses of additional panels
  • Install code (inactive)
  • Language: Romana, English, Francais, Italiano, Polski, Deutsch, Eesti, Greek
  • Security – enabling/disabling the anti-theft alarm
  • Dial config – setting up the call number of the apartment
  • Information

Step 3
Set all parameters required for the installed configuration.

  • Change the screen with the key.
  • Change the menu with the key.

Terminals
The terminals are programmed from the factory with Address 1 = number of the first terminal in the system.

In multi-family systems, the terminals will be programmed with the number (address) of each family:

  • Step 1 At the terminal, press the key – long beep.

  • Step 2 Short touch of the key:

    • 2 touches = Address 2 – 2 beeps

    • 3 touches = Address 3 – 3 beeps

    • n touches = Address n – n beeps

Programming mode disabling
Short-touch the PROG button at SCU to exit programming mode →The red LED turns off.