ELECTRA VPE.0BF03.ELB(W)TL Touch Line Video Intercom User Manual
- September 20, 2024
- Electra
Table of Contents
- ELECTRA VPE.0BF03.ELB(W)TL Touch Line Video Intercom
- Product Information
- Product Usage Instructions
- Specifications
- Warranty
- Safety instructions
- Cables and installation
- Connection diagrams
- Installation
- Programming
- Contact Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELECTRA VPE.0BF03.ELB(W)TL Touch Line Video Intercom
Product Information
Specifications:
- Dimensions & Weight:
- VPE.0BF03.ELB(W)TL: 354 x 127 x 42 mm / 2.1 kg
- VPE.0BS03.ELB(W)TL: 341 x 113 x 36 mm / 1.9 kg
- Material: Aluminium-Case + Secured Glass
- IP Rating: IP44
- Operating Temperature: -30°C to +80°C
- Camera: CMOS 1.3, 800 TVL video camera with RFID card access
- Operating Voltage: 11 to 14 Vd.c.
- Stand-by Current: 60 mAd.c. (Summer), 130 mAd.c. (Winter)
- Operating Current: 220 mAd.c. (Summer), 300 mAd.c. (Winter)
Product Usage Instructions
-
Safety Instructions:
Ensure to follow the safety instructions provided in the manual for proper installation and usage of the video outdoor panels. -
Warranty Information:
A 24-month warranty is provided for non-conformity and/or hidden defects based on the purchase document. The warranty does not cover incorrect installation, breakage, theft, fire, floods, or RFID access cards. -
Cables and Installation:
Refer to the provided connection diagrams for proper installation of cables and connections. Use UTP/FTP cat5e or cat6 cables for connections within the specified range. -
Connection Diagrams:
Follow the connection diagrams provided in the manual for connecting the outdoor panel to the central unit using the specified cables and optional RJ45 connections.
FAQ:
-
Q: What is the warranty coverage for the video outdoor panels?
A: The warranty covers non-conformity and hidden defects for 24 months based on the purchase document. -
Q: What should I do in case of incorrect installation?
A: Warranty is not applicable for incorrect installations; ensure to follow the installation guidelines provided in the manual for proper setup.
Specifications
Warranty
- A 24-month warranty is granted, according to the existing legislation, based on the purchase document.
- Warranty is granted for non-conformity and/or hidden defects.
- Warranty is NOT granted for: incorrect installation and/ or operation, non-compliant with this manual; broken glass, blows, mechanical shocks; theft, fire, floods, natural disasters; unprotected products during renovation activities; the RFID access cards (tags), which are considered consumables.
Safety instructions
Cables and installation
Connection diagrams
Installation
Orientation of the video panel camera
Mounting on the wall – Surface panel
Mounting on the wall – Flush panel
Mounting on the wall – Flush panel
smart 4.3″ VIDEO terminal
smart/extra 7″ VIDEO terminal
Connection box – 4 outputs
Connection box – 4 outputs
Programming
Programming mode enabling
Long press the PROG button at SCU to enter the programming mode →The red LED
turns on.
Video outdoor panel
Step 1
Long touch the key at the panel →The panel confirms with a long BEEP. The
display shows:
Step 2
Enter the producer’s PIN code (0000) →The panel confirms with a long BEEP. The
display shows the following MENU:
- Change PIN – programming a new, personalized PIN code
- Add new tag – programming the RFID access CARDs/ TAGs
- Change address – programming the addresses of additional panels
- Install code (inactive)
- Language: Romana, English, Francais, Italiano, Polski, Deutsch, Eesti, Greek
- Security – enabling/disabling the anti-theft alarm
- Dial config – setting up the call number of the apartment
- Information
Step 3
Set all parameters required for the installed configuration.
- Change the screen with the key.
- Change the menu with the key.
Terminals
The terminals are programmed from the factory with Address 1 = number of
the first terminal in the system.
In multi-family systems, the terminals will be programmed with the number (address) of each family:
-
Step 1 At the terminal, press the key – long beep.
-
Step 2 Short touch of the key:
-
2 touches = Address 2 – 2 beeps
-
3 touches = Address 3 – 3 beeps
… -
n touches = Address n – n beeps
-
Programming mode disabling
Short-touch the PROG button at SCU to exit programming mode →The red LED turns
off.
Contact Information
MADE in EU by:
-
ELECTRA s.r.l
Parc Industrial Miroslava Str. Principala 33, 707307, Jud. Iași – RO -
+40 232 214.370
SUPPORT
-
ELECTRA Building Communications GmbH
Gadnergasse 71, Stockwerk 1, Büro Top 132 1110 Wien – AT -
+43 1 810 20 99