CORDIVARI RF Digital Remote Control User Manual

June 10, 2024
CORDIVARI

CORDIVARI RF Digital Remote Control

Product Information:
The product is a thermostat with RF (radio frequency) capabilities. It comes with two AA batteries and a support for table mounting. The package also includes two anchoring screws and two screws for fixing the base plate. The thermostat has a temperature level display, consumption indicator, ambient temperature measurement, boost indicator, open window detection indicator, keypad lock, and date and time display. It also has a heating/cooling icon, battery wear level indicator, presence/absence detection indicator, RF transmission indicator, and minimum/maximum value indicator. The product manual is written in Italian. Product Usage

Instructions:

  1. Open the battery cover on the front of the thermostat and insert two AA batteries.
  2. Remove the frame from the thermostat by unscrewing the two screws underneath it.
  3. Fix the base plate to the wall using the two screws provided through the horizontal and vertical holes. 4. Place the thermostat back onto the frame and
    secure it by screwing in the two screws underneath it. 5. For table mounting, insert the two tabs into the frame and slide the support
    to the right. Then, reposition the battery cover. 6. Fold and lock the support into the frame. 7. Tilt the thermostat according to its
    location in the room. 8. The display shows temperature level, consumption, ambient temperature, boost, open window detection, keypad lock, and date and time. 9. The heating/cooling icon indicates whether the device is heating or cooling. 10. The battery wear level indicator shows how much battery life is left. 11. The
    presence/absence detection indicator shows whether someone i present or not.
  4. The RF transmission indicator shows whether the device is transmitting via radio frequency. 13. The minimum/maximum value indicator shows the minimum and maximum temperature values.
    To tune RF settings: 1. Press and hold the Boost button for 5 seconds. 2. The product will automatically tune RF settings for 30
    seconds. 3. To cancel the process, press any button.

\

1. Pack contains

Screw Anchor x2
AA Batteries (LR6) x2
1.1 Installing batteries

User manual

Screw for base attaching x2

1.2 Mounting of thermostat · On the wall

1. Unscrew the 2 screws under the thermostat.

2. Remove the wallplate from the thermostat.

Thermostat table

stand x1

x2

3. Secure the wall plate with the two screws provided using the horizontal and vertical holes.

4. Replace the thermostat on the wallplate.

1. Remove the batterie cover which is placed on the front of the thermostat.

5. Secure the thermostat by screwing the locking screws under the thermostat.

x2

· On the table stand

2. Insert the 2 AA batteries supplied. Note the correct polarity according to the engraving on the thermostat when inserting the batteries.

1. Insert the 2 pins inside the wallplate.

2. Slide the stand to the right.

3. Replace the batterie cover.

– 24 –

Cod. 1910000000274 – nv01

English

3. Fold the stand and lock it into the wallplate.

· LCD display (Indicators overview)
8

4. Tilt the thermostat according to its placement in the room. 2 tilts are available.

30°

37°

2. Controls and display
· Thermostat buttons overview

1. Temperature setpoint/information.

2. Gauge consumption

3. Measured ambient temperature

4. Boost indicator light.

5. Open window detection indicator.

6. Keypad locked

7. Days of the week (1=monday … 7= sunday)

8. Operating modes auto :

Auto mode – Comfort mode – Eco

mode – Frost protection mode – Time and date setting mode –

Programming mode – Settings

9. Heating/cooling indicator

10. Low battery indicator

11. Occupancy detection indicator

12. Radio trasmission indicator

13. Min/Max value indicator

Important: In Auto, Comfort, Eco and Standby mode, backlight turns off automatically after 4 seconds if no buttons are pressed. It will be necessary to reactivate it by pressing one of the keypad buttons before making settings.

RF pairing and management

· RF pairing between the remote control and the device The remote control and the devide are not paired together at the factory, then proceed ad follow:

1. From frost protection mode, press pairing process, press any button.

for 5 seconds. To cancel the

2

5

34

1. Batteries compartment. 2. Selecting operating modes. 3. Plus and minus buttons, used to set temperatures, time, date and pro-
grammes. 4. Save settings. 5. Boost button. 6. Rotary dial 7. LCD display

Cod. 1910000000274 – nv01

– 25 –

English

2. The remot is in pairing mode. Then proceed to the device control pairing (refer to its installing and using instruction manual).

The symbol disappear from the display, the remote control and the device are not associated anymore.

3. When both device and remote control are linked, the symbol appears and is constantly displayed. The device returns automatically to the frost protection mode.

Operating

Before carrying ot any setting procedures, ensure that the keypa is indeed unlocked.

Power on / Standby mode When the device is on standby mode, 2 lines appear on the remote control display. To exit standby mode, press the standby button (refer to the device’s instruction manual).

· Check the RF signal strengh (only if paired) You can check at any time the RF transmission performace between hte device and the remote control. To view the RF reception level, from Frost protection mode, press for 5 seconds. Then the level appears on the dispaly.
Level of the remote control
Level of the connected devide

Selecting the operation mode

The button allows you to adapt the operating schedule of your device to your needs, depending on the season, whether your home is occupied or not. By pressing the

button once or several times, select the requiredmode.

0 = High RF transmission level, the location of the remote control is optimized. 9 = Low RF transmission level: To improve the RF transmission performance between the 2 devices and ensure the remote management is optimized: – Please ensure the RF transmission is not interrupted, move the remote control. – Move the remote control closer to the device.

· RF pairing cancellation

You can cancel at any time the RF transmission between the device and the remote control.

From frost protection mode press simultaneously and for 5 seconds.

Mode sequence:

Auto

Comfort

Eco

Frost protection

Mode overview
· Auto mode In Automatic Mode, the device will automatically change from Comfort mode to Eco mode according to the established programme.

2 different cases depending on your set-up:
1. 7 day and daily programme Your device has been programmed and is executing Comfort and Eco mode orders in line with the settings and time periods you have selected (see “7 day and daily programme integrated” chapter).

– 26 –

Cod. 1910000000274 – nv01

English

2. Without programme On the version without occupancy detector, if the 7 day and daily programme is not enabled or no orders are being sent by pilot wire, then your device’s factory setting mean that it will operate in non-stop Comfort mode, 7 days of the week.

· First press: Boost

  • Comfort mode Non-stop Comfort mode. The device will operate 24 hours a day to achieve the temprature which has been set (e.g. 19°C). The Comfort mode temperature level can be set by the user.
  •  Eco mode Eco, which means the Comfort Modetemperature minus 3.5°C. This enables you to lower the temprature without having to reset the Comfort Mode temperature. Select this mode for short-term absences (between 2 and 24h) or during the night.

Comments: – If the heating indicator is switched on, the device switches on and heats the room in addition to the heat emitted by the device. – At any time, you can modify the Boost duration from 0 to the maximal authorised duration of the Boost, such as defined during the advanced setting by intervals of 5 minutes by turing the dial. This modification will be saved and effective for the next Boost.
If the ambient temperature reaches the maximal Boost temperature during the count:
Comments: The device switches off but the Boost mode is always active: the count is always displayed, the Boost symbol and the heating indicator flash on the display. When the temperature drops under the maximal authorised temperature, the device will be restarted until the count ends.

· Frost protection mode This mode enables you to protect your home against the effects of cold weather (frozen, pipes, etc.), by maintaining a minimum temperature of 7*C in it at all times. Select this mode when you will be away from your home for a long time (more than 5 days)

· Second press: Boost cancellation The cursor moves above the previous active mode and the setting temperatura appears.

3.3 Boost feature Important: the Boost mode can be enabled at any time, whatever the current operating mode (Auto, Comfort, Eco or Frost protection).

To activate Boost mode, press

the desired temperature setting

will be set at maximum for the time period you request. 60 minutes

display will flash by default.

·

3.4 Super Comfort The blower could be used as an instant additional heating in case of an inportant difference between the ambient temperature and the desired temperature setting. The Super Comfort switches on if the difference between the ambient temperature and the setting temperature is higher than 2°C. The Super Comfort is enabled by default (see chapter “User settings” then “Super Comfort mode”).
Example: The device is in Eco set 17,5°C, you decide to switch in Comfort mode: the different between 21°C and 17,5°C is 3,5°C, so higher than 2°C. The blower starts up automatically to help the temperature increase and attain the 21°C desired. The Boost symbol and the heating indicator appears on the display and the cursor above the selected mode will flash.

Cod. 1910000000274 – nv01

– 27 –

English

Scf and the setting temperature Super Comfort appears on the display. The Super Comfort stops if: – The difference is less or equal to 0,5°C. – The differenza is always higher than 2°C after 1 hour of Super Comfort.

Comment : The Super Comfort is only valid in Comfort mode and Auto mode.

3.5 Gauge consumption, energy savings In the device display, an indicator shows the energy comsumption level by positioning in front of the colour: red, orenge or green. You can choose your level of energy usage, depending on the setting temperature. As the temperature setting increases, the consumption will be higher. The gauge appears in Auto, Comfort, Eco and Frost protection modes and whatever the temperature level.

· Resetting the energy meter

To reset the energy meter, from Auto, Comfort, Eco or Frost protection

mode, then proceed as follows.

1- Press

.

2- Press simultaneously

and

for more than 5 seconds. To

exit resetting the energy meter, press any button, the devices returns

automatically in the previous active mode.

C – Red colour High Temperature level: it is advisable
to significantly reduce the setting
temperature.

Setting teperature > 22°C
When the setting temperature is higher
than 22°C

3.8 Child anti-tamper, keypad lock/unlock

· Keypad lock

To lock the keypad, press and hold the

and

buttons for 10

seconds. The padlock symbol appears on the display, the keypad is

locked.

B – Orange colour

19°C <Setting

Average tempe-

teperature 22°C

rature level: it is When the setting tem-

advisable to slightly perature is higher than

reduce the setting 19°C and lower or equal

temperature.

to 22°C

A – Green colour Ideal settings.

Setting teperature 19°C
When the setting tempe-
rature is lower or equal
to 19°C

· Keypad unlock

To unlock the keypad, press and hold the

and

buttons for 10

seconds again. The padlock symbol disappears from the display, keypad

is unlocked.

Important: when the keypad is locked, only the button (or switch) is active.

3.6 Setting the Comfort mode temperature You can access the Comfort temperature set up from the Auto and Comfort Modes. It is preset to 19°C. Using the rotary dial, you can adjust the temperature from 7°C to 30°C by intervals of 0.5°C. Note: you can limit the Comfort temperature (for more details see the specific chapter).

If the device is on Standby mode when the keypad is locked, you have to unlock it for the next heating on to access the setup.

3.9 7 day and daily programme integrated, energy savings

3.9.1. Automatic programming with self-lkearning process This feature is available on products equipped with occupancy detector.

3.7 Consumption indication accumulated in KWH, energy savings It is possible to see the estimation of energy consumption in KWH since the last reset of the energy meter.

· Display of the estimated power consumption

To see this estimation, from Auto, Comfort, Eco or Frost protection mode,

then press

. To exit the display mode of consumption: press

or

, the device returns automatically in the previous active mode.

· Overview Auto-programming (Auto): After an initial learning period of one week, the device will analyze occupancy cycles to determine and implement a weekly programme adapted to your lifecycle alternating periods in comfort and periods in eco, the goal being to deliver the most efficient yet comfortable and user focused heating cycle. The products algorithm will perpetually learn and adapt to changes in your occupancy patterns, adapting week after week to optimize the heating programme to any changes in your evolving

– 28 –

Cod. 1910000000274 – nv01

occupancy patterns

· Operating Upon the first activation of your device, the mode “auto- programme” is activated by default, in mode Auto. To deactivate and change the programme,see choice and affectation of programmes. The first week of operation is a learning week during which the device memorizes your habits and elaborates a programme for the week. It therefore defines a programme built up of periods of Comfort and Eco, independently for each day of the week. During this learning week, the device will provisionally function in permanent “Comfort” mode.

Example of display in Comfort period

Example of display in Eco period

The clock symbol appears.

2- Select using

or

. The hours figures will flash. The hours will

scroll quickly if you hold the

or

buttons. Save by press

.

Important: To ensure the auto-programming is optimized, please ensure the presence detection sensor is not obstructed by an external source, refer to your device’s instruction manual.

· Application of the intelligent programme One week after switching on, the device will apply the new programme for the next 7 days. Then week after week the device will continue to optimize the intelligent programme “Auto”, adjusting the Comfort and Eco periods to fit closely to your lifestyle. When the product is in Frost protection mode or in standby mode for mode than 24 hours, learning and optimization of the intelligent programme stops: the device stores the previously recorded programme from the last week before switching to the Frost protection or standby mode. – Example 1: If the product is installed in mid-season or if its installation is anticipated on the construction site, it can be switched on in standby mode. When you select the Auto mode, the learning week will start automatically. The device will be in permanent comfort and will memorize your habits to aplly the adapted programme the following week.

3- The minutes figures will flash. Select using .

or . Save by pressing

– Example 2: In the case of control by pilot wire coming from an energy manager for example, the pilot wire will take precedence over the AUTO programme which results from the Self-learning algorithm.

3.9.2. 7 day and daily programme In this mode, you have the option of programming your device, by setting one of the five programmes on offer each day of the week.

· Access to the programming mode From Auto, Comfort, Eco or Frost protection mode, press seconds to enter into the programming mode..

for 5

4- The cursor above the number 1 (which represents the monday) will flash.

Select the day using

or

. Save by pressing

.

Schematic sequence of programming settings:

Setting time

Setting day

Programmes choice

· Setting day and time In this mode, you can set day and time to programme your device in line with your needs.

1- From Auto, Comfort, Eco or Frost protection mode, press seconds.

for 5

Cod. 1910000000274 – nv01

– 29 –

English

5- To change and/or allocate programmes, press

day mode, press

3 times.

. To exit the time and

2- Press

or . prog appears.

· Programmes choices

Schematic sequence of programmes:

Auto

Comfort

Eco

P1

P2

P3

Version with occupancy detector: The device is delivered by default with the self-learning mode enabled. If this programme suits your requirements, you have nothing more to do, the device, after the initial 7 day learning period will follow the autoprogramme which will continue to tailor itself to your occupancy cycles. Other version: your device’s default setting is non-stop Comfort for 7 days a week.

· Programmes overview – Auto: Auto-programming (See Automatic programming with selflearning process). – Comfort: Your device will operate in Comfort mode, 24 hours a day, for wach day selected. Nota: You can se the Comfort mode temperature to the temperature you require (see the Setting the Comfort mode temperature section). – Eco: The device will operate 24 hours a day in Eco mode. Nota: You can set the temperature lowering parameters. – P1: Your device will operate in Comfort mode from 06:00 to 22:00 (and in Eco mode from 22:00 to 06:00). – P2: Your device will operate in Comfort mode from 06:00 to 09:00 and from 16:00 to 22:00 (and in Eco mode from 09:00 to 16:00 and from 22:00 to 06:00). – P3:Your device will operate in Comfort mode from 06:00 to 08:00, from 12:00 to 14:00 and from 18:00 to 23:00 (and in Eco mode from 23:00 to 06:00, from 08:00 to 12:00 and from 14:00 to 18:00).

3- With

or , select P1.

P1 will flash. Press

for 5 seconds to make changes.

5 sec.

· Potential modifications of programmes

4- The P1 start time (which by default is 06:00) will flash. Using

or

If the default time schedules for the P1, P2 and P3 programmes do not suit you can change this time, by increments of 3 minutes.

your routines, you can change them.

Modifying the P1, P2 o P3 programmes. If you modify the time schedules for the P1, P2 or P3 programmes, the schedules will be modified for all the days of the week for which P1, P2 or P3 had been set.

1- If you just set the time and day, go to step 2.

From Auto, Comfort, Eco or Frost protection mode, press

for 5 seconds.

When the cursor moves above the setting time symbol press

shortly.

Save by pressing

.

– 30 –

Cod. 1910000000274 – nv01

English

5- The P1 and time (which by default is 22:00) will flash. Using , you can change this time, by increments of 30 minutes.

or Other version: The days of the week will scroll on display with the programmes that you set for them, meaning Comfort (ConF) every day.

Press

or

. The programme set for day 1 (1 = monday, 2 =

thursady ecc.) will flash.

Save by pressing

.

6- Once all the days of the week are programmed, press

twice to exit.

Note: without action on the keys, it will return to Auto after a few minutes.

· Choise and allocation programmes

1- If you just set the time and day, the cursor moves automatically under prog.

From Auto, Comfort, Eco or Frost protection mode, than press

for 5

seconds. When the cursor positionned under the set time symbol , press

again.

Prior information: display area

Correspondence days / numbers

Monday

1

Tuesday

2

Wednesday

3

Thursday

4

Friday

5

Saturday

6

Sunday

7

3- Choose the programme you want for this day with

or

.

Save by pressing

.

Version with occupancy detector: The days of the week are all displayed. The default programme Auto appears on the display.

4- The programme assigned to the second day of the week (Tuesday) will flah. Repeat the procedure described previously (in point 3) for each day of the week.

Press

or

. The programme affected by dafault, Auto, flashes.

It will be applied to all the days of the week.

Cod. 1910000000274 – nv01

– 31 –

English

5- Once you have chosen a programme for each day, confirm your selection

by pressing

.

The days of the week will succesively scroll on display with the programmes

that you set for them (P1, P2, P3, CONF or ECO). To exit the programme

viewing mode, press

twice.

· Viewing the programmes that you have selected

– From Auto, Comfort, Eco or Frost protection mode, press

for 5 seconds.

Press

twice, the programme for each day of the week (Comfort, Eco,

P1, P2 or P3).

– To exit the programme viewing mode, press

twice.

· Manual and temporary exemption from a running programme This function allows you to change the setting temperature temporarily until the next scheduled change in temperatre or the transition to 00:00.

Example :

· Automatic activation (factory settings) The device detects a temperature fall. An opened window, a door to the outside, can cause this temperature fall. Note: The difference between the air from the inside and the outside must cause a significant temperature fall to be perceptible by the device. This temperature drop detection triggers the change to Frost Protection mode.
· Frost protection digital meter When the device performs a lower temperature cycle due to opened window, a meter appears on the display to show he cycle time. The counter is automatically reset the next time Frost protection by opened window is activated (automatic or manual activation).
· Stop the Frost protection mode By pressing any button, you stop the Frost protection mode. Note: If a temperature rise is detected, the device may return to the previous mode (active mode before the open window detection).
4. User settings

4.1 Access

Access to the User settings in 2 steps: From Auto, Comfort, Eco or Frost

protection mode:

1- Press

for 5 seconds.

1- By using the rotary dial, you can change temporarily the desired temperature up to 18°C for example.

Note: The cursor corresponding to the operation mode, i.e Eco mode in our example, is blinking during the duration of the temporary derogation.

2- Press

3- This change will be automatically cancelled at the next change of programme or transition to 00:00.

briefly twice.

3.10 Open window detection, energy savings

User = User settings is displayed

· Overview Lowering temperature cycle by setting frost protection during ventilation of a room by opened window. You can access the open window detection from the Comfort, Eco and Auto modes. – Automatic activation, the lowering temperature cycle starts as soon as the device detects a temperature change.

– 32 –

Cod. 1910000000274 – nv01

English

Setting sequence : Eco mode temperature lowering-level Frost protezione temperature Super comfort Comfort setting temperature limits Maximal Boost duration Maximum ambient temperature Restoring factory settings

4.4 Super Comfort activation/deactivation By default, the Super Comfort is enabled.

4.2 Setting the Eco mode temperature lowering-level The drop in temperature is set at -3,5°C compared to the set temperature of the Comfort mode. You can adjust the lowered level from -1°C to -8°C, by intervals of 0,5°C. Important: whatever the lowering level set, the Eco setting temperature will never exceed 19°C.

1- Press

or

to obtain the temperature level you require.

SCF appears, then YES flashes on the display. The Boost symbol and

the heating indicator appear on the display.

5- Press

or

to enable or disable the Super Comfort.

2- Press

to save and move to the next setting.

YES = Super Comfort enabled.

no = Super Comfort disabled.

To save and move to the next setting, press

press

twice.

. To exit the user settings,

4.5 Comfort setpoint temperature limit You can limit the setting temperature range by introducing a maximum and/or minimum setting, preventing unintentional changes in temperature.

To exit the user settings, press

twice.

4.3 Setting the frost protection temperature Your device is preset at 7°C. You can adjust the Frost protection temperature from 5°C to 15°C by intervals of 0,5°C.

· Low temperature limit

Locking of the setting range using a minimum temperature stop, preventing

the temperature from being set below that temperature. The minimum setting

is preset to 7°C. You can adjust from 7°C to 15°C by intervals of 1°C.

6- To change the minimum temperature setting, press

or

then save by pressing

. If you do not want to change it, press

:

the device changes automatically to set the maximum setting. To exit the user

settings, press

twice

3- Press

or

to obtain the temperature you require.

4- Press

to save and move to the next setting. To exit the user

settings, press

twice.

· High temperature limit Locking ofthe setting range using a maximum temperature increase, preventing the temperature from being set above that temperature. The maximum setting is preset to 30°C. You can adjust from 19°C to 30°C by

Cod. 1910000000274 – nv01

– 33 –

English

intervals of 1°C.

7- To change the maximum temperature setting, press

or

11- You can set the Boost maximum temperature by pressing

or

from 25°C to 39°C by intervals of 1°C.

To save and move to the next setting, press

press

twice.

. To exit the user settings,

4.6 Setting of the maximum duration of authorised Boost The maximum duration of Boost is preset at 60 min. You can adjust it from 30 to 90 min, by intervals of 30 min.

8- The Boost symbol and the heating indicator appear on the display and the preset duration of 60 min flash.

12- To save and move to the next setting, press

settings, press

twice.

. To exit the user

4.8 Restoring factory settings (only if PIN code is desabled)

In order to return to the factory settings, proceed in the following order:

1- From the maximum ambient temperaturre setting, press

.

rEST appears on the display.

9- Press

or

to display the desires duration.

2- no Appars . Press

or

to select YES.

10- To save and move to the next setting, press

settings, press

twice.

. To exit the user

4.7 Setting of the maximum ambient temperature for the automatic stop of the Boost

YES = Factory settings reset. no = Factory settings not reset.

When the Boost is enabled, the device has to heat the room until the temperature limit: the maximum ambient temperature. When it is reached, the Boost stops automatically. It is preset at 35°C, you can adjust it from 25°C to 39°C by intervals of 1°C.

3- Press

for 5 seconds. The device returns to its initial configuration

and goes back automatically to the home display of the user settings.

The Boost symbol and the heating indicator appear on the display and the maximum temperature flashes.

– 34 –

Cod. 1910000000274 – nv01

USEr = User settings is displayed .

English

3- Press

for 10 seconds.

The following factory values will be effective:

Parameters

Factory settings

Operating

Comfort setting temperature

19°C

Boost duration

60 min.

Keypad lock

Disabled

User settings

60 min.

Eco mode temperature lowerin glevel -3,5°C

Frost protection temperature Super Comfort

7°C Enabled

Minimum set of Comfort setting temperature

7°C

Maximum set of Comfort setting temperature

30°C

Maximal Boost duration

60 min.

Maximum ambient temperature for the automatic stop of the Boost

35°C

InSt= Installer settings is displayed.

Press

briefly.

Setting sequence : Configuration of detection modes Dual optimization feature PIN code lock Restoring factory settings.

5.2 Configuration of detection modes

Press

to exit the user settings.

5. Installer settings
5.1 Access To access the Installer settings in steps: From Auto, Comfort, Eco or Frost protection mode:

· Open window detection, activation/deactivation of the Auto mode
The default setting of the automatic mode is enabled.

1- Press

for 5 seconds.

1- Press

or .

On = Automatic mode enabled.

OFF = Automatic mode disabled.

2- Press

briefly twice.

Cod. 1910000000274 – nv01

2- To save and move to the next setting, press

settings, press

3 times.

To exit the installer

· Occupancy detection, activation/deactivation 1- The occupancy detection enabled is the default setting.

– 35 –

English

2- Press

or .

On = Occupancy detection enabled.

OFF = Occupancy detection disabled.

1- Press

or .

3- To save and move to the next setting, press

settings, press

3 times.

To exit the installer

5.3 Dual optimization feature This feature is available on the device equipped with occupancy detector.

· Overview – Dual function optimization, priority to comfort or energy savings, the choice is yours, depending on various parameters: room inertia, ambient temperature, desired temperature, the device calculates and optimizes the programming for each heating period whether set to Comfort or Savings (Eco): – In OPTI ECO mode (efficiency priority), the device’s inbuilt algorithms will calculate the best compromise in order to guarantee maximum energy savings throughout the programmed increase and decrease phases. In this mode, a slight drop in the temperature level at the beginning and end of the comfort period is allowed to maximize energy savings. – In OPTI COMFORT mode (priority to comfort), the device’s intelligence calculates the best compromise in order to guarantee maximum comfort during the programmed increase and decrease phases. In OPTI COMFORT mode, the priority is given to anticipating and maintaining the comfort temperature during periods of detected occupancy .

COnF = Optimisation feature activated for OPTI Comfort mode, priority to comfort. ECO = Optimisation feature activated for OPTI ECO mode, priority to energy efficiency. OFF = Optimisation feature disactivated.

2- To save and move to the next setting, press

settings, press

3 times.

To exit the installer

5.4 PIN code lock · Overview Your heating device is protected by a safety code against unauthorised use. The PIN code (Personal Identity Number) is a customisable 4 numbers code. When enabled, it prevents access to the following settings: – Selecting the Comfort mode: The access tothe Comfort mode is forbidden, only the Auto, Eco and Frost protection modes are available – Minimum and maximum limits of the setting temperature range (the Comfort temperature modification is forbidden out of the authorised setting range). – Programming mode. – Open window detection settings. – Setting the Eco mode temperature lowering-level. – Setting the Frost protection temperature.

· Optimization choice The OPTI COMFORT mode is activated by default. The word OPTI will appear briefly on the display then it will alternate with the set mode CoNF, ECO or OFF.

Version with occupancy detector, in addition: – Occupancy detection settings. – Optimization choice. 3 important steps are needed for the first use of the PIN code lock: 1 – PIN code initialisation, enter the preset PIN code (0000) to access the feature. 2 – Activation of the PIN code, to lock settings which will be protected by the PIN code. 3 – Customizing the PIN code, replace 0000 by the custmized code.

· PIN code initialisation By default, the PIN code is not enabled. 1- OFF appears on the display.

– 36 –

Cod. 1910000000274 – nv01

By default registered PIN code is 0000.

Press

or

to select 0. Save by pressing

.

English

The PIN code is enabled. Any modification of reserved settings listed in “Overview” is now impossible.

· Customizing the PIN code If you have just activated the PIN code, follow the steps described below. Alternatively, you must copy the steps 1 and 2 of the initialisation process as well as the steps 1 and 2 of the activation process before personalising the PIN code.

1- When On appears, press

for at least 5 seconds.

2- For others numbers, select 0 by press

press on

again to save and exit.

. When 0000 appears,

2- The 0000 code appears and the first number blinks. Press

or

, to select the first desired number then press to save and

exit. Repeat this operation for the remaining 3 numbers.

The PIN code is initialized, the next setting appears: PIN code activation.

· Activation/deactivation of the PIN code

1- OFF appears on the display.

Press

or

to enabled PIN code.

ON appears on the display.

ON = PIN code enabled

OFF = PIN code disabled

3- Press

to confirm. The new code is now saved.

2- Press

to save and return to the home installer settings display.

Cod. 1910000000274 – nv01

– 37 –

English

4- Press again on

to exit setting PIN code mode and go back to the

home display of the installer settings.

To exit the installer setting, press

twice.

5.5 Restoring factory settings (only if PIN code is desabled)

If the PIN code protection is disabled, the user and installer settings are

reinitialized:

1- From the PIN code setting, press

. rEST appears briefly on the

display.

2- no appears . Press

or

to select YES.

The following factory values will be effective:

Settings

Factory settings

Operation

Comfort setting temperature

19°C

Boost duration

60 min.

Keypad lock

Disabled

User settings

60 min.

Eco mode temperature lowering level -3,5°C

Frost protection temperature Super Comfort

7°C Enabled

Minimum set of Comfort setting temperature

7°C

Maximum set of Comfort setting temperature

30°C

Maximal Boost duration

60 min.

Maximum ambient temperature for the automatic stop of the Boost

35°C

Installer settings

7°C

Automatic open window detection

Enabled

Occupancy detection

Enabled

Dual optimization feature

Opti Comfort

Presence / absence sensor

Enabled

PIN code protection

Disabled

PIN code

0000

To exit the user setting, press

twice.

6. Expert settings

6.1 Access

To access the expert settings in 4 steps. From Auto, Comfort, Eco or

Frost protection mode:

1- Press

for 5 seconds.

YES = Factory settings reset. no = Factory settings not reset.

3- Press the key

for 5 seconds. The device returns to its initial

configuration and goes back automatically tothe home display of the

installer settings.

– 38 –

Cod. 1910000000274 – nv01

2- Press

briefly twice.

USEr = User settings is displayed.

English
· Ambient temperature sensor adjustement 1- If the ambient temperature difference is negative, example: Setting temperature (what you want) = 20°C. Ambient temperature (what you read on a reliable thermometer) = 18°C. Difference measured = -2°C.
Important: Before carrying out the calibration it is recommended to wait for 4h after the setting temperature modification to insure that the ambient temperature is stabilized.
To correct, then proceed as follows: Sensor temperature = 24°C (The measured temperature may be different due to the location of the thermostat in the room).

3- Press

for 10 seconds.

InST = Instaler settings is displayed.

Decrease the temperature measured by the ambient temperature sensor

by 2°C pressing

. In example, the measured temperature by the

sensor goes from 24°C to 22°C.

4- Press and hold

and

simultaneous for 10 seconds.

2- If the ambient temperature difference is positive, example: Setting temperature (what you want) = 19°C. Ambient temperature (what you read on a reliable thermometer) = 21°C. Difference measured = +2°C.

Setting sequence : Ambient temperature sensor adjustement Restoring factory settings.

To correct, then proceed as follows: Sensor temperature = 21°C (The measured temperature may be different due to the location of the thermostat in the room)

6.2 Ambient temperature sensor adjustement · Overview Important: This operation is reserved for professional installers only; any wrong changes would result in control anomalies.

In which case if the temperature measured(measured by reliable thermometer) is different by at least 1°C or 2°C compared to the setting temperature of the radiator. The calibration adjusts the temperature measured by the ambient temperature sensor to compensate for a deviation from + 5°C to -5°C by intervals of 0,1°C.

Increase the temperature measured by the ambient temperature sensor

by 2°C by pressing

. In example, the measured temperature by the

sensor goes from 21°C to 23°C.

Cod. 1910000000274 – nv01

– 39 –

English

3- Press the key

for 5 seconds. The device returns to its initial

configuration and goes back automatically to the home display of the

instaler settings.

To validate the new value press 3 times.

. To exit the EXpert settings, press

Important: These changes should be performed by a qualified professional installer, they should be performed in production or on site during the first installation.

6.3 Restoring factory settings (only if PIN code is disabled)

If the PIN code is disabled, the user and installer settings are reinitialized:

1- From the PIN code, press

. rEST appears briefly on the display.

2- no appars . Press

or

to select YES.

The following factory values will be effective:

Settings

Factory settings

Operation

Comfort setting temperature

19°C

Boost duration

60 min.

Keypad lock

Disabled

User settings

60 min.

Eco mode temperature lowering level -3,5°C

Frost protection temperature Super Comfort

7°C Enabled

Minimum set of Comfort setting temperature

7°C

Maximum set of Comfort setting temperature

30°C

Maximal Boost duration

60 min.

Maximum ambient temperature for the automatic stop of the Boost

35°C

Automatic open window detection

Enabled

Occupancy detection

Enabled

Dual optimization feature

Opti Comfort

PIN code protection

Disabled

Expert settings

Opti Comfort

Reg. Ambient temperature sensor

0,0

PIN code

0000

Ambient temperature sensor adj.

0,0

To exit the expert settings, press

3 times.

7. Troubleshooting
Batteries are used inadapted. – Replace the 2 batteries. Only use alkaline 1,5V LR6 batteries. Do not use rechargeable batteries.

YES = Factory settings reset. no = Factory settings not reset.

The heating does not come on or does not go off. – Your remote control may have been set up close to a source of heat or on a cold wall – put it in a recommended location (see the “Installing” section for these locations). – No power supply to the device: check the fuse and the circuit breaker..

The ambient temperature is lower than the required temperature – Refer tothe device instruction manual.

Radio transmission is not working properly : 1- The device is not picking up the code sent by the emitter. – Replace transmitter’s batteries. 2- The device does not recognize transmitter’s code. – Pair the remote control transmitter with the device again.

– 40 –

Cod. 1910000000274 – nv01

English

The device of the remote control is affected by interference : – Move the remote control out of the affected area. – Try to move away the device or the source of the interference

The Super Comfort or Boost didn’t start : – Check the Super Comfort or Boost duration (refer tothe Boost duration section). – Check programming ­ refer to the «Viewing programmes» section. – Check that the time and the day have been correctly set on your programmable remote control ­ refer to the «Viewing day and time settings» section – Check that the kind of application has been correctly set

Please refer to the troubleshooting section on instruction manual of your device. If the problem persists, contact your installer.

Technical specifications

Power supply: 2 alkaline 1,5 V LR6 batteries. Battery life: approx 2 years.

Maximum range in the home: 15m typical but this varies depending on the equipment being used in conjunction with the appliance (the appliance’s range can be adversely affected by the way in which a system is set up and by the surrounding electromagnetic environment. – Signal sending: every 3 minutes, maximum time-lag 1 minute after setpoint temperature has been changed. – Radio frequency: 2,4035 Ghz/ 2,4055 Ghz / 2,4075 Ghz – Maximum RF power transmitted: <1mW. Environment : – Operation temperature: from 0°C to +40°C. – Manual temperature setting range: from +5°C to +30°C. – Storage temperature: from -10°C to +60°C. – Humidity: 80% to +25°C (without condensation). – Protection rating: IP30.

Disposal
At the end of life, this appliance must be deposited in the special collection centres for recycling, it is not an ordinary household waste. In case of replacement, the radiator can be sent to your distributor. Managing in this way, the end of life of a product allows us to preserve our environment, to limit the use of natural resources. This symbol on the product indicates the obligation to deliver to the end of his life to a collection point specialist, in accordance with Directive 2012/19/UE.

DECLARATION OF CONFORMITY
The Company Cordivari S.r.l. with registered office in Morro D’Oro (TE), Zona Industriale Pagliare, hereby declares, under its own responsibility, that the household electric radiators listed in par.1 comply with following rules:

– RED 2014/53/UE – Article 3.1a (Safety): EN62311:2008 – Article 3.1b (EMC): ETSI EN 301489-1 V2.1.0 (2016) / ETSI EN 301489-3 V2.1.0 (2016) – Article 3.2 (RF): ETSI EN 300440 V2.1.1 (2016) – ERP 2009/125/EC – Regulation 2015/1188/UE -ROHS 2011/65/UE: EN50581 and are manufactured using processes which are certified ISO 9001 V2008

Morro D’Oro lì 29/05/2020

Cod. 1910000000274 – nv01

Cod. 1910000000274 – nv01

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals