NPP-450 series

Features

Mulit-function single unit battery charger or power supply operation modes selectable

  • Output voltage and current adjustable via potentiometer
  • 3-stage charging curve for charging mode
  • -30~+70℃ wide operating temperature
  • Multiple protections: Short circuit / Over load / Over voltage / Over temperature
  • Thermal controlled DC fan for noise reduction
  • Remote ON-OFF control
  • Comply with 62368-1+60335-1/-2-29 dual certification
  • Suitable for lead-acid (Pb) batteries
  • Carry handle accessory available (Order NO.:DS-Carry handle, sold separately)
  • 3 years warranty

Applications

  • Radio system backup solution
  • Electric scooter charger
  • Camping car、Buses、Heavy duty truck、Specialty vehicles
  • Surveillance system
  • lndustrial automation machinery
  • lndustrial control system
  • Mechanical and electrical equipment

Description

NPP-450 is a miniaturized dual-purpose charger and power supply. ln addition to being used as a three- stage charger for lead-acid batteries, it can also be used as a constant voltage output power supply to drive general load. The operating mode can be quickly switched by plugging or unplugging a connector on the front panel. Other features include: ultra-wide voltage output, adjustable voltage via VR on the panel (10.5~21V, 21~42V, 42~80V, 54~100V), adjustable charging current (50~100%),  built-in intelligent fan with variable speed based on temperature to reduce noise and extend fan lifetime, – 30~+70° C wide operating temperature, suitability for use in different environments, built-in remote ON/OFF control, compliance to lEC/EN/UL62368-1 and household EN60335-1/-2-29 dual safety, multiple built-in protections, and 3-year warranty. The NPP-450 is truly an intelligent, safe, and reliable universal dual-purpose charger and power supply with outstanding cost performance.

■  Model Encoding  MEAN WELL NPP-450 Series 450W High Reliable Ultra
Wide Output Range Battery Charger and Power Supply - model
1

SPECIFICATION for Battery Charger mode (Default)

MODEL NPP-450-12 NPP-450-24 NPP-450-48 NPP-450-72






OUTPUT

| BOOST CHARGE **VOLTAGE(Vboost)(default)| 14.4V| 28.8V| 57.6V| 72V
FLOAT CHARGE VOLTAGE(Vfloat)(default)| 13.8V| 27.6V| 55.2V| 69V
VOLTAGE ADJUSTABLE RANGE| 10.5 ~ 21V| 21 ~ 42V| 42 ~ 80V| 54 ~ 100V
By built-in potentionmeter
MAX. OUTPUT CURRENT(CC)| 25A| 13.5A| 6.8A| 5.5A
CURRENT ADJUSTABLE RANGE Note.3| 12.5 ~ 25A| 6.75 ~ 13.5A| 3.4 ~ 6.8A| 2.75 ~ 5.5A
By built-in potentionmeter
MAX. POWER| 420W| 453.6W| 456.96W| 462W
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.4**| 90 ~ 300AH| 45 ~ 155AH| 24 ~ 80AH| 19 ~ 64AH




INPUT

| VOLTAGE RANGE| Note.5| 90 ~ 264VAC        127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)| Note.6| 92%| 93%| 93%| 93%
AC CURRENT (Typ.)| 4.5A/115VAC
2.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START  50A at 230VAC



PROTECTION

| SHORT CIRCUIT| Note.7| Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover


OVER VOLTAGE

| 21.5 ~ 26V| 43 ~ 52V| 82 ~ 100V| 102 ~ 120V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down O/P voltage, recovers automatically after temperature goes down



FUNCTION

| CHARGING STAGE| 3 stage only
CHARGER OK SIGNAL| The TTL signal out, Charger OK = H(4.5 ~ 5.5V)
Charger failure or protection status =L( -0.5 ~ +0.5V)
BATTERY FULL SIGNAL| The TTL signal out, Battery full = H(4.5 ~ 5.5V ); Charging = L(-0.5 ~ +0.5V)
REMOTE CONTROL| Open : Charger stop charging
Short : Charger normal work
FAN SPEED CONTROL| Depends on internal temperature




ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC**

(Note 8)

| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Dekra BS EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN61000-6-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS| MTBF| 352.3K hrs min. Telcordia SR-332 (Bellcore) ; 118.5K hrs min.| MIL-HDBK-217F (25℃)
DIMENSION| 20513055mm (LWH)
PACKING| 1.02Kg; 8pcs/ 10Kg / 1.71CUFT
NOTE| 1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. Float charge voltage(Vfloat) adjustable via potentiomerter in battery charger mode.
4. This is MEAN WELL’s suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6.  The efficiency is measured at 16.8V charge voltage(12V model), 33.6V charge voltage(24V model), 67.2V charge voltage(48V model), 84V charge voltage(72V model).
7. This protection mechanism is specified for the case the short circuit occurs after the charger is turned on.
8.  The charger is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com)
9.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

SPECIFICATION for Power Supply mode (Selectable via pin3 & 4 jumper of 14pins connector on panel)

MODEL NPP-450-12 NPP-450-24 NPP-450-48 NPP-450-72
OUTPUT DC VOLTAGE 14.4V 28.8V 57.6V
VOLTAGE ADJUSTABLE RANGE 10.5 ~ 21V 21 ~ 42V 42 ~ 80V 54 ~ 100V

By built-in potentionmeter
CURRENT ADJUSTABLE RANGE| 12.5 ~ 25A| 6.75 ~ 13.5A| 3.4 ~ 6.8A| 2.75 ~ 5.5A
RATED CURRENT| 25A| 13.5A| 6.8A| 5.5A
RATED POWER| 420W| 453.6W| 457W| 462W
RIPPLE & NOISE(max.)| 180mVp-p| 300mVp-p| 480mVp-p| 600mVp-p
VOLTAGE TOLERANCE| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1800ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC at 75% load   10ms/230VAC at full load




INPUT

| VOLTAGE RANGE Note.3| 90 ~ 264VAC        127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)| 92%| 93%| 93%| 93%
AC CURRENT (Typ.)| 4.5A/115VAC         2.2A/230VAC
INRUSH CURRENT(Typ.)| COLD START  50A at 230VAC




PROTECTION

| ****

OVERLOAD

| 105 ~ 115% rated output power
Protection type : Constant current limiting, unit will shutdown after 5 sec, re-power on to recover


OVER VOLTAGE

| 21.5 ~ 26V| 43 ~ 52V| 82 ~ 100V| 102 ~ 120V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down O/P voltage, recovers automatically after temperature goes down


FUNCTION

| REMOTE CONTROL| Open : Power OFF
Short : Power ON
DC OK| The TTL signal out, DC OK = H(4.5 ~ 5.5V) ; Power supply failure or protection = L(-0.5 ~ +0.5V)
FAN SPEED CONTROL| Depends on internal temperature




ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC**

(Note 4)

| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Dekra BS EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH




EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN61000-6-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS| MTBF| 352.3K hrs min. Telcordia SR-332 (Bellcore) ; 118.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 20513055mm (LWH)
PACKING| 1.02Kg; 8pcs/ 10Kg / 1.71CUFT
NOTE| 1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
3. Derating may be needed under low input voltages. Please check the derating curve for more details.
4.  The PSU is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com)
5.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

MEAN WELL NPP-450 Series 450W High Reliable Ultra Wide Output Range Battery
Charger and Power Supply - Diagram

Function Manual
1. Battery Charger or Power Supply Operation modes selectable via pin3 and pin4 jumper

Between pin3 and pin4 Operation modes
Jumper connected Power supply  mode
Jumper removed Battery charger mode (Default)

MEAN WELL NPP-450 Series 450W High Reliable Ultra Wide Output Range Battery
Charger and Power Supply - function

2. Charging Curve (Charging Mode)
◎ 3 stage charging curveMEAN WELL NPP-450 Series 450W High Reliable Ultra
Wide Output Range Battery Charger and Power Supply - charging
device

State NPP-450-12 NPP-450-24 NPP-450-48 NPP-450-72
Constant Current 25A 13.5A 6.8A 5.5A
Vboost 14.4V 28.8V 57.6V 72V
Vfloat 13.8V 27.6V 55.2V 69V

◎ Suitable for lead-acid batteries (flooded, Gel and AGM)MEAN WELL NPP-450
Series 450W High Reliable Ultra Wide Output Range Battery Charger and Power
Supply - function 2

※ V O x I O must be less than or equal to the rated power. Please refer to derating curve (page 4) .
3. Charger OK / DC OK Signal
Charger OK / DC OK signal is a TTL level signal. The maximum sourcing current is 10mA.

Charger OK / DC OK signal Charger status
“High” : 4.5 ~ 5.5V Work normally
“Low” : -0.5 ~ 0.5V Failure or protection function activated

MEAN WELL NPP-450 Series 450W High Reliable Ultra Wide Output Range Battery
Charger and Power Supply - function 3 4. Remote ON-OFF Control
The NPP-450 can be turned ON/OFF by using the “Remote Control” function.

Between pin7 remote ON-OFF and pin8 +12Vaux Charger status
Short ( Pin 7 = 10.8 ~ 13.2V) ON (Default)
Open ( Pin 7 = -0.5 ~ 0.5V) OFF

MEAN WELL NPP-450 Series 450W High Reliable Ultra Wide Output Range Battery
Charger and Power Supply - function 4

Mechanical Specification

MEAN WELL NPP-450 Series 450W High Reliable Ultra Wide Output Range Battery
Charger and Power Supply - medical function ※ Connector Pin No. Assignment : HRS DF11-14DP-2DS or equivalent

Pin No.

| Assignment| Mating Housing|

Terminal

---|---|---|---
1,2,11~14| NC| HRS DF11-14DS or equivalent| HRS DF11-**SC or equivalent
3,4| Battery Charger or Power Supply mode selectanle
5| Battery Full
6| Charger OK (Charger mode) or
DC OK (Power supply mode)
7| Remote ON-OFF
8| +12V-AUX
9,10| GND-AUX

※ LED Status Table

Charger (Default)

LED Indicator| Status
Green| Float stage (stage 3) or full charged
Red| Charging (stage 1 or stage 2)
O No Light| Abnormal
Power supply mode
LED Indicator| Status
Green| Normal working
O No Light| Abnormal

Control Pin No. Assignment : HRS DF11-14DP-2DS or equivalent

Mating Housing HRS DF11-14DS or equivalent
Terminal HRS DF11-**SC or equivalent
Pin No. Function

Description

---|---|---
1,2,11~14| NC| —–
3,4| Battery charger / Power supply| Open: Battery charger, Color of LED loading indicator: Reference to battery charger. Short: Power supply, Color of LED loading indicator :Green.
5| Battery Full| Battery Full Signal,  referenced to  GND-AUX(Pin 9  & 10).
The Signal is a TTL level signal. The maximum sourcing current is 10mA and only for output.(Note.2) Low (-0.5 ~ 0.5V) : When the battery is charging.
High (4.5 ~ 5.5V) : When the battery is full.
6| Charger OK / DC OK| Charger OK / DC OK Signal, referenced to GND-AUX(Pin 9 & 10).
The Signal is a TTL level signal. The maximum sourcing current is 10mA and only for output.(Note.2) Low (-0.5 ~ 0.5V) : When the charger fails or the protect function is activating.
High (4.5 ~ 5.5V) : When the charger is working properly.
7| Remote ON-OFF| Remote charger ON/OFF Function.
The charger can turn the output ON/OFF by dry contact between Remote ON-OFF and +12V-AUX.(Note.2) Short (10.8 ~ 13.2V) : Charger ON ; Open(-0.5 ~ 0.5V) : Charger OFF ; The maximum input voltage is 13.2V.
8| +12V-AUX| It is controlled by the Remote ON-OFF control.
9,10| GND-AUX| The signal return is isolated from the output terminal. (+V & -V)

Note1: Non-isolated signal, referenced to [GND(signal)].
Note2: Isolated signal, referenced to GND-AUX

Accessory List

※ Battery Charger or Power Supply mode of pin 3 and pin 4 mating pin along with NPP-450 (Standard accessory)

Pin 3 and Pin 4 mating pin Quantity
1FF1HMJ20-020-95BS or equivalent 1

※ Carry handle (Optional accessory, battery charger and pull handle should be ordered seperately)

MW’s Order No.

| Item|

Quantity

---|---|---
DS-Carry Handle| 1|

Handle

| 1
2|

Foot pad

| 4
3| Screw| 2

MEAN WELL NPP-450 Series 450W High Reliable Ultra Wide Output Range Battery
Charger and Power Supply - medical function 3 INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
https://www.meanwell.com/Upload/PDF/NPB,NPP-E.pdf

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals