MEAN WELL NPP-450 Series 450W High Reliable Ultra Wide Output Range Battery Charger and Power Supply 2-in-1 Instruction Manual
- June 10, 2024
- MEAN WELL
Table of Contents
NPP-450 Series 450W High Reliable Ultra Wide
Output Range Battery Charger and Power Supply 2-in-1
Instruction Manual 450W High
Reliable Ultra Wide Output Range Battery Charger & Power Supply 2-in-1
NPP-450 series
Features
Mulit-function single unit battery charger or power supply operation modes selectable
- Output voltage and current adjustable via potentiometer
- 3-stage charging curve for charging mode
- -30~+70℃ wide operating temperature
- Multiple protections: Short circuit / Over load / Over voltage / Over temperature
- Thermal controlled DC fan for noise reduction
- Remote ON-OFF control
- Comply with 62368-1+60335-1/-2-29 dual certification
- Suitable for lead-acid (Pb) batteries
- Carry handle accessory available (Order NO.:DS-Carry handle, sold separately)
- 3 years warranty
Applications
- Radio system backup solution
- Electric scooter charger
- Camping car、Buses、Heavy duty truck、Specialty vehicles
- Surveillance system
- lndustrial automation machinery
- lndustrial control system
- Mechanical and electrical equipment
Description
NPP-450 is a miniaturized dual-purpose charger and power supply. ln addition to being used as a three- stage charger for lead-acid batteries, it can also be used as a constant voltage output power supply to drive general load. The operating mode can be quickly switched by plugging or unplugging a connector on the front panel. Other features include: ultra-wide voltage output, adjustable voltage via VR on the panel (10.5~21V, 21~42V, 42~80V, 54~100V), adjustable charging current (50~100%), built-in intelligent fan with variable speed based on temperature to reduce noise and extend fan lifetime, – 30~+70° C wide operating temperature, suitability for use in different environments, built-in remote ON/OFF control, compliance to lEC/EN/UL62368-1 and household EN60335-1/-2-29 dual safety, multiple built-in protections, and 3-year warranty. The NPP-450 is truly an intelligent, safe, and reliable universal dual-purpose charger and power supply with outstanding cost performance.
■ Model Encoding
SPECIFICATION for Battery Charger mode (Default)
MODEL | NPP-450-12 | NPP-450-24 | NPP-450-48 | NPP-450-72 |
---|
OUTPUT
| BOOST CHARGE **VOLTAGE(Vboost)(default)| 14.4V| 28.8V|
57.6V| 72V
FLOAT CHARGE VOLTAGE(Vfloat)(default)| 13.8V| 27.6V| 55.2V| 69V
VOLTAGE ADJUSTABLE RANGE| 10.5 ~ 21V| 21 ~ 42V| 42 ~ 80V| 54 ~ 100V
By built-in potentionmeter
MAX. OUTPUT CURRENT(CC)| 25A| 13.5A| 6.8A| 5.5A
CURRENT ADJUSTABLE RANGE Note.3| 12.5 ~ 25A| 6.75 ~ 13.5A|
3.4 ~ 6.8A| 2.75 ~ 5.5A
By built-in potentionmeter
MAX. POWER| 420W| 453.6W| 456.96W| 462W
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.4**| 90 ~ 300AH| 45
~ 155AH| 24 ~ 80AH| 19 ~ 64AH
INPUT
| VOLTAGE RANGE| Note.5| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)| Note.6| 92%| 93%| 93%| 93%
AC CURRENT (Typ.)| 4.5A/115VAC
2.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A at 230VAC
PROTECTION
| SHORT CIRCUIT| Note.7| Protection type : Constant current limiting, charger will shutdown after 5 sec, re-power on to recover
OVER VOLTAGE
| 21.5 ~ 26V| 43 ~ 52V| 82 ~ 100V| 102 ~ 120V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down O/P voltage, recovers automatically after
temperature goes down
FUNCTION
| CHARGING STAGE| 3 stage only
CHARGER OK SIGNAL| The TTL signal out, Charger OK = H(4.5 ~ 5.5V)
Charger failure or protection status =L( -0.5 ~ +0.5V)
BATTERY FULL SIGNAL| The TTL signal out, Battery full = H(4.5 ~ 5.5V );
Charging = L(-0.5 ~ +0.5V)
REMOTE CONTROL| Open : Charger stop charging
Short : Charger normal work
FAN SPEED CONTROL| Depends on internal temperature
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC**
(Note 8)
| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Dekra BS
EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN61000-6-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods, >95% interruptions 250 periods
OTHERS| MTBF| 352.3K hrs min. Telcordia SR-332 (Bellcore) ; 118.5K
hrs min.| MIL-HDBK-217F (25℃)
DIMENSION| 20513055mm (LWH)
PACKING| 1.02Kg; 8pcs/ 10Kg / 1.71CUFT
NOTE| 1. Modification for charger specification may be required for
different battery specification. Please contact battery vendor and MEAN WELL
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated
load and 25℃ of ambient temperature.
3. Float charge voltage(Vfloat) adjustable via potentiomerter in battery
charger mode.
4. This is MEAN WELL’s suggested range. Please consult your battery
manufacturer for their suggestions about maximum charging current limitation.
5. Derating may be needed under low input voltages. Please check the derating
curve for more details.
6. The efficiency is measured at 16.8V charge voltage(12V model), 33.6V
charge voltage(24V model), 67.2V charge voltage(48V model), 84V charge
voltage(72V model).
7. This protection mechanism is specified for the case the short circuit
occurs after the charger is turned on.
8. The charger is considered a component which will be installed into a final
equipment. All the EMC tests are been executed by mounting the unit on a
600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-
confirmed that it still meets EMC directives. For guidance on how to perform
these EMC tests, please refer to “EMl testing of component power supplies.”
(as available on http://www.meanwell.com)
9. The ambient temperature derating of 3.5℃/1000m with fanless models and of
5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
SPECIFICATION for Power Supply mode (Selectable via pin3 & 4 jumper of 14pins connector on panel)
MODEL | NPP-450-12 | NPP-450-24 | NPP-450-48 | NPP-450-72 |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 14.4V | 28.8V | 57.6V |
VOLTAGE ADJUSTABLE RANGE | 10.5 ~ 21V | 21 ~ 42V | 42 ~ 80V | 54 ~ 100V |
By built-in potentionmeter
CURRENT ADJUSTABLE RANGE| 12.5 ~ 25A| 6.75 ~ 13.5A| 3.4 ~ 6.8A| 2.75
~ 5.5A
RATED CURRENT| 25A| 13.5A| 6.8A| 5.5A
RATED POWER| 420W| 453.6W| 457W| 462W
RIPPLE & NOISE(max.)| 180mVp-p| 300mVp-p| 480mVp-p| 600mVp-p
VOLTAGE TOLERANCE| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1800ms, 60ms/230VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC at 75% load 10ms/230VAC at full load
INPUT
| VOLTAGE RANGE Note.3| 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)| 92%| 93%| 93%| 93%
AC CURRENT (Typ.)| 4.5A/115VAC 2.2A/230VAC
INRUSH CURRENT(Typ.)| COLD START 50A at 230VAC
PROTECTION
| ****
OVERLOAD
| 105 ~ 115% rated output power
Protection type : Constant current limiting, unit will shutdown after 5 sec,
re-power on to recover
OVER VOLTAGE
| 21.5 ~ 26V| 43 ~ 52V| 82 ~ 100V| 102 ~ 120V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down O/P voltage, recovers automatically after
temperature goes down
FUNCTION
| REMOTE CONTROL| Open : Power OFF
Short : Power ON
DC OK| The TTL signal out, DC OK = H(4.5 ~ 5.5V) ; Power supply failure
or protection = L(-0.5 ~ +0.5V)
FAN SPEED CONTROL| Depends on internal temperature
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC**
(Note 4)
| SAFETY STANDARDS| CB IEC62368-1,IEC60335-1/2-29, Dekra BS
EN/EN62368-1,BS EN/EN60335-1/2-29, UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN61000-6-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2, 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods, >95% interruptions 250 periods
OTHERS| MTBF| 352.3K hrs min. Telcordia SR-332 (Bellcore) ; 118.5K
hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 20513055mm (LWH)
PACKING| 1.02Kg; 8pcs/ 10Kg / 1.71CUFT
NOTE| 1. Modification for charger specification may be required for
different battery specification. Please contact battery vendor and MEAN WELL
for details.
2. All parameters NOT specially mentioned are measured at 230VAC input, rated
load and 25℃ of ambient temperature.
3. Derating may be needed under low input voltages. Please check the derating
curve for more details.
4. The PSU is considered a component which will be installed into a final
equipment. All the EMC tests are been executed by mounting the unit on a
600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-
confirmed that it still meets EMC directives. For guidance on how to perform
these EMC tests, please refer to “EMl testing of component power supplies.”
(as available on http://www.meanwell.com)
5. The ambient temperature derating of 3.5℃/1000m with fanless models and of
5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
Function Manual
1. Battery Charger or Power Supply Operation modes selectable via pin3
and pin4 jumper
Between pin3 and pin4 | Operation modes |
---|---|
Jumper connected | Power supply mode |
Jumper removed | Battery charger mode (Default) |
2. Charging Curve (Charging Mode)
◎ 3 stage charging curve
State | NPP-450-12 | NPP-450-24 | NPP-450-48 | NPP-450-72 |
---|---|---|---|---|
Constant Current | 25A | 13.5A | 6.8A | 5.5A |
Vboost | 14.4V | 28.8V | 57.6V | 72V |
Vfloat | 13.8V | 27.6V | 55.2V | 69V |
◎ Suitable for lead-acid batteries (flooded, Gel and AGM)
※ V O x I O must be less than or equal to the rated power. Please
refer to derating curve (page 4) .
3. Charger OK / DC OK Signal
Charger OK / DC OK signal is a TTL level signal. The maximum sourcing
current is 10mA.
Charger OK / DC OK signal | Charger status |
---|---|
“High” : 4.5 ~ 5.5V | Work normally |
“Low” : -0.5 ~ 0.5V | Failure or protection function activated |
4.
Remote ON-OFF Control
The NPP-450 can be turned ON/OFF by using the “Remote Control” function.
Between pin7 remote ON-OFF and pin8 +12Vaux | Charger status |
---|---|
Short ( Pin 7 = 10.8 ~ 13.2V) | ON (Default) |
Open ( Pin 7 = -0.5 ~ 0.5V) | OFF |
Mechanical Specification
※ Connector Pin No. Assignment : HRS DF11-14DP-2DS or equivalent
Pin No.
| Assignment| Mating Housing|
Terminal
---|---|---|---
1,2,11~14| NC| HRS DF11-14DS or equivalent| HRS DF11-**SC or equivalent
3,4| Battery Charger or Power Supply mode selectanle
5| Battery Full
6| Charger OK (Charger mode) or
DC OK (Power supply mode)
7| Remote ON-OFF
8| +12V-AUX
9,10| GND-AUX
※ LED Status Table
Charger (Default)
LED Indicator| Status
Green| Float stage (stage 3) or full charged
Red| Charging (stage 1 or stage 2)
O No Light| Abnormal
Power supply mode
LED Indicator| Status
Green| Normal working
O No Light| Abnormal
Control Pin No. Assignment : HRS DF11-14DP-2DS or equivalent
Mating Housing | HRS DF11-14DS or equivalent |
---|---|
Terminal | HRS DF11-**SC or equivalent |
Pin No. | Function |
Description
---|---|---
1,2,11~14| NC| —–
3,4| Battery charger / Power supply| Open: Battery charger, Color of LED
loading indicator: Reference to battery charger. Short: Power supply, Color of
LED loading indicator :Green.
5| Battery Full| Battery Full Signal, referenced to GND-AUX(Pin 9 & 10).
The Signal is a TTL level signal. The maximum sourcing current is 10mA and
only for output.(Note.2) Low (-0.5 ~ 0.5V) : When the battery is charging.
High (4.5 ~ 5.5V) : When the battery is full.
6| Charger OK / DC OK| Charger OK / DC OK Signal, referenced to GND-AUX(Pin 9
& 10).
The Signal is a TTL level signal. The maximum sourcing current is 10mA and
only for output.(Note.2) Low (-0.5 ~ 0.5V) : When the charger fails or the
protect function is activating.
High (4.5 ~ 5.5V) : When the charger is working properly.
7| Remote ON-OFF| Remote charger ON/OFF Function.
The charger can turn the output ON/OFF by dry contact between Remote ON-OFF
and +12V-AUX.(Note.2) Short (10.8 ~ 13.2V) : Charger ON ; Open(-0.5 ~ 0.5V) :
Charger OFF ; The maximum input voltage is 13.2V.
8| +12V-AUX| It is controlled by the Remote ON-OFF control.
9,10| GND-AUX| The signal return is isolated from the output terminal. (+V &
-V)
Note1: Non-isolated signal, referenced to [GND(signal)].
Note2: Isolated signal, referenced to GND-AUX
Accessory List
※ Battery Charger or Power Supply mode of pin 3 and pin 4 mating pin along with NPP-450 (Standard accessory)
Pin 3 and Pin 4 mating pin | Quantity |
---|---|
1FF1HMJ20-020-95BS or equivalent | 1 |
※ Carry handle (Optional accessory, battery charger and pull handle should be ordered seperately)
MW’s Order No.
| Item|
Quantity
---|---|---
DS-Carry Handle| 1|
Handle
| 1
2|
Foot pad
| 4
3| Screw| 2
INSTALLATION MANUAL
Please refer to : http://www.meanwell.com/manual.html
https://www.meanwell.com/Upload/PDF/NPB,NPP-E.pdf
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>