Fronius Primo GEN24 Plus Hybrid Inverter Owner’s Manual
- June 10, 2024
- Fronius
Table of Contents
Fronius Primo GEN24 Plus Hybrid Inverter Owner’s Manual
Maximum flexibility
With the Fronius GEN24 or Fronius GEN24 Plus as the core of your PV system, you will not only be starting your own energy revolution, you will also gain access to all the possibilities and advantages of solar energy. With “Fronius UP”, your PV system becomes even more flexible. A software update turns the Fronius GEN24 into our Fronius GEN24 Plus hybrid inverter
Backup power for every situation
Reliable energy supply: The Fronius GEN24 offers with “PV Point” an integrated basic backup power function. With the Fronius GEN24 Plus, you can choose “PV Point” or, with “Full Backup” *, a backup power supply for the entire household.
Built-in freedom
The Fronius GEN24 and Fronius GEN24 Plus have open interfaces. This means third-party components can be easily integrated in the system – for a customised PV system.
Easy to install
Saves time and money: Quick and reliable installation with 180° quick release screws, push-in tension clamp terminals and a well thought-out wall mounting system.
Support & tools
Endless support: Efficient Fronius solutions are available free of charge to help with planning, installation and system monitoring. This increases customer satisfaction and minimises maintenance expense.
Fronius GEN24 is available in two versions:
- Inverter: Fronius GEN24
- Hybrid inverter: Fronius GEN24 Plus
Impressive performance data
The Fronius GEN24 and Fronius GEN24 Plus stand out thanks to maximum efficiency and maximum output at high temperatures.
Efficiency
Power derating
Technical data
| Primo GEN24/GEN24 Plus
---|---
3.0| 3.6| 4.0
__Input data| Number of MPP trackers| | | 2| | | 2| | | 2|
DC input voltage range| V| 65 – 600| 65 – 600| 65 – 600
(V DC min – V DC max)
Nominal input voltage (V DC,r)| V| | 400| | | 400| | | 400|
Feed-in start voltage (V DC start)| V| 80| 80| 80
Usable MPP voltage range| V| | 65 – 530| | | 65 – 530| | | 65 – 530|
| | MPPT1| MPPT2| MPPT1| MPPT2| MPPT1| MPPT2
Max. usable input current (I DC max)| A| 22| | 12| 22| | 12| 22| | 12
Max. module array short circuit current| A| 36| 19| 36| 19| 36| 19
(Isc pv) 1
Number of DC connections| | 2| | 2| 2| | 2| 2| | 2
| | MPPT1| MPPT2| Total| MPPT1| MPPT2| Total|
MPPT1| MPPT2| Total
Max. usable DC output| W| 3,110| 3,110| 3,110| 3,810| 3,810| 3,810| 4,140|
4,140| 4,140
Max. PV generator output| Wpeak| 3,750| 3,110| 4,500| 4,600| 3,810| 5,520|
5,000| 4,140| 6,000
Output data| AC rated power (P AC,r)| W| 3,000| 3,680| | | 4,000
---|---|---|---|---|---|---|---
Apparent power| VA| 3,000| 3,680| 4,000
Max. output power| VA| 3,000| 3,680| | | 4,000
| | 220 VAC| 230 VAC| 220 VAC| 230 VAC| 220 VAC|
230 VAC
Nominal AC output current (@ 220/230 V)| A| 13.6| 13| 16.7| 16| 18.2| 17.4
Grid connection (V AC,r)| V| 1~ EN 220/230 (+20%/-30%)
Frequency(frequency range fmin – fmax)| Hz| 50/60 (45 – 65)
Total harmonic distortion| %| < 2| < 2| | | < 2
Power factor (cos φac,r)| | 0.8 – 1 ind. / cap.
Output data PV Point| Nominal output power PV Point| VA| 3,000| 3,000|
3,000
---|---|---|---|---|---
PV Point grid connection| V| 1~ EN 220/230
Switchover time| sec.| < 35| < 35| < 35
Full Backup emergency power and battery function only available with GEN24 Plus
Full Backup emergency power and battery function only available with
GEN24 Plus| Primo GEN24 Plus
---|---
3.0| 3.6| 4.0
Output data Full| Nominal Full Backup output power| VA| 3,000| 3,600|
4,000
Full Backup grid connection| V| 1~ EN 220/230
Switchover time| sec.| < 20| < 20| < 20
Battery connection| Number of DC inputs| | 1| 1| 1
---|---|---|---|---|---
Max. input current (I DC max)| A| 22| 22| 22
DC input voltage range (UDC min. -UDC max.) 3| V| 150 – 455| 150 – 455|
150 – 455
DC battery connection technology| | 1× BATT+ and 1× BATT- push-in tension
clamp terminals 2.5 – 10 mm²
Max. DC input/output power 4| W| 3,110| 3,810| 4,140
Max. charging power with AC coupling 4| W| 3,000| 3,680| 4,000
Compatible batteries 5| | BYD Battery-Box Premium HVS/HVM 6
- Isc pv = Isc max. ≥ Isc (STC) x 1.25 according to e.g. IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.
- The Full Backup option is available for the Primo GEN24 3.0–6.0 Plus. Additional external components for grid switchover are required for the Full Backup. See the Operating Instructions for further details.
- AC power derating of the inverter occurs with a DC battery input voltage of 419.7 V and higher
- Depending on the connected battery
- Depending on country-specific certification and availability
- Excluding BYD Battery-Box Premium HVS 10.2, HVS 12.8, HVM 8.3, HVM 22.1
| Primo GEN24 / Primo GEN24 Plus
---|---
3.0| 3.6| 4.0
General data| Dimensions (height × width × depth)| mm| 530 × 474 × 165
Weight (inverter/with packaging)| kg| 15.4/19| 15.4/19| 15.4/19
Degree of protection| | IP 66| IP 66| IP 66
Safety class| | 1| 1| 1
Night-time consumption| W| < 10| < 10| < 10
Overvoltage category (DC/AC) 7| | 2/3| 2/3| 2/3
Inverter concept| | Transformerless
Cooling| | Active Cooling Technology
Installation| | Indoor and outdoor installation
Ambient temperature range| °C| -40 to +60| -40 to +60| -40 to +60
Permissible humidity| %| 0 – 100| 0 – 100| 0 – 100
Noise emissions| dB (A)| < 42| < 42| < 42
Max. altitude| m| 4,000| 4,000| 4,000
DC PV connection technology| | 4 × DC+ and 4 × DC- push-in tension clamp
terminals 2,5 – 10 mm²
| | 3-pin AC push-in tension clamp terminals 2.5 – 10 mm²
AC connection technology| 3-pin backup power push-in tension clamp terminals
1.5 – 10 mm²
| 2 × PE screw terminals 2.5 – 16 mm² and 3 × 2.5 – 10 mm²
Certificates and compliance with| | IEC 62109, IEC 62909, AS/NZS 4777.2, CEI
0-21,
standards 8| ABNT BNR 16149 und 16150, IEC 62116, IEC 61727 , G98/G99,
R25
Backup power functions 9| | PV Point and Full Backup
Producing country| | Austria
Life Cvcle Assessment| | According to ÖNORM EN ISO 14040 and 14044
(verified by employees of Fraunhofer IZM)
Efficiency| Maximum efficiency| %| 97.6| 97.6| 97.6
---|---|---|---|---|---
European efficiency (ηEU)| %| 96.8 97.0
97.1
MPP adjustment efficiency| %| > 99.9| > 99.9| > 99.9
Protective devices| DC isolation measurement| | Integrated
---|---|---|---
Overload performance| | Operating point adjustment, power limitation
DC disconnector| | Integrated
Reverse polarity protection| | Integrated
Interfaces| Wi-Fi / 2 × Ethernet LAN| | Fronius Solar.web, Modbus TCP
SunSpec, Fronius Solar API (JSON)
---|---|---|---
6 digital inputs6 digital inputs/outputs| | Interface to ripple control
receiver, energy management
Emergency shutdown (WSD)| | Integrated
Datalogger and web server| | Integrated
2 × RS485| | Modbus RTU SunSpec (third-party provider) / Fronius Smart Meter,
Battery (GEN24 Plus), Fronius Ohmpilot
- In line with IEC 62109-1. Option to retrofit surge protection device DC SPD type 1+2 for 2 MPP trackers available under the following item number: 4,240,313,CK
- You can find the current certificates under www.fronius.com/primo-gen24-plus cert
- Full Backup emergency power and battery function only available with GEN24 Plus
For further information on the availability of the inverters in your country, please visit www.fronius.com.
| Primo GEN24/GEN24 Plus
---|---
4.6| 5.0| 6.0
__Input data| Number of MPP trackers| | | 2| | | 2| | | 2|
DC input voltage range| V| 65 – 600| 65 – 600| 65 – 600
(V DC min – V DC max)
Nominal input voltage (V DC.r)| V| | 400| | | 400| | | 400|
Feed-in start voltage (V DC start)| V| 80| 80| 80
Usable MPP voltage range| V| | 65 – 530| | | 65 – 530| | | 65 – 480|
| | MPPT1| MPPT2| MPPT1| MPPT2| MPPT1| MPPT2
Max. usable input current (I DC max)| A| 22| | 12| 22| | 12| 22| | 12
Max. module array short circuit current| A| 36| 19| 36| 19| 36| 19
(Isc pv) 1
Number of DC connections| | 2| | 2| 2| | 2| 2| | 2
| | MPPT1| MPPT2| Total| MPPT1| MPPT2| Total|
MPPT1| MPPT2| Total
Max. usable DC output| W| 4,750| 4,750| 4,750| 5,170| 5,170| 5,170| 6,200|
5,760| 6,200
Max. PV generator output| Wpeak| 5,750| 4,750| 6,900| 6,250| 5,170| 7,500|
7,500| 5,760| 9,000
Output data| AC rated power (P AC,r)| W| 4,600| 5,000| | | 6,000
---|---|---|---|---|---|---|---
Apparent power| VA| 4,600| 5,000| 6,000
Max. output power| VA| 4,600| 5,000| | | 6,000
| | 220 VAC| 230 VAC| 220 VAC| 230 VAC| 220 VAC|
230 VAC
Nominal AC output current| A| 20.9| 20| 22.7| 21.7| 27.3| 26.1
(@ 220/230 V)
Grid connection (V AC,r)| V| 1~ EN 220/230 (+20%/-30%)
Frequency| Hz| 50/60 (45 – 65)
(frequency range fmin – fmax)
Total harmonic distortion| %| < 2| < 2| | | < 2
Power factor (cos φac,r)| | 0.8 – 1 ind. / cap.
Output data PV Point| Nominal output power PV Point| VA| 3,000| 3,000|
3,000
---|---|---|---|---|---
PV Point grid connection| V| 1~ EN 220/230
Switchover time| sec.| < 35| < 35| < 35
Full Backup emergency power and battery function only available with GEN24
Plus| Primo GEN24 Plus
---|---
4.6| 5.0| 6.0
Output data Full| Nominal Full Backup output power| VA| 4,600| 5,000|
6,000
Full Backup grid connection| V| 1~ EN 220/230
Switchover time| sec.| < 20| < 20| < 20
Battery connection| Number of DC inputs| | 1| 1| 1
---|---|---|---|---|---
Max. input current (I DC max)| A| 22| 22| 22
DC input voltage range (UDC min. -UDC max.) 3| V| 150 – 455| 150 – 455|
150 – 455
DC battery connection technology| | 1 × BATT+ and 1× BATT- push-in tension
clamp terminals 2,5 – 10 mm²
Max. DC input/output power 4| W| 4,750| 5,170| 6,200
Max. charging power with AC coupling 4| W| 4,600| 5,000| 6,000
Compatible batteries 5| | BYD Battery-Box Premium HVS/HVM 6
- Isc pv = Isc max. ≥ Isc (STC) x 1.25 according to e.g. IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021.
- The Full Backup option is available for the Primo GEN24 3.0–6.0 Plus. Additional external components for grid switchover are required for the Full Backup. See the Operating Instructions for further details.
- AC power derating of the inverter occurs with a DC battery input voltage of 419.7 V and higher
- Depending on the connected battery
- Depending on country-specific certification and availability
- Excluding BYD Battery-Box Premium HVS 10.2, HVS 12.8, HVM 8.3, HVM 22.1
| Primo GEN24/GEN24 Plus
---|---
4.6| 5.0| 6.0
General data| Dimensions (height × width × depth)| mm| 530 × 474 × 165
Weight (inverter/with packaging)| kg| 15.4/19| 15.4/19| 15.4/19
Degree of protection| | IP 66| IP 66| IP 66
Safety class| | 1| 1| 1
Night-time consumption| W| < 10| < 10| < 10
Overvoltage category (DC/AC) 7| | 2/3| 2/3| 2/3
Inverter concept| | Transformerless
Cooling| | Active Cooling Technology
Installation| | Indoor and outdoor installation
Ambient temperature range| °C| -40 to +60| -40 to +60| -40 to +60
Permissible humidity| %| 0 – 100| 0 – 100| 0 – 100
Noise emissions| dB (A)| < 42| < 42| < 42
Max. altitude| m| 4,000| 4,000| 4,000
DC PV connection technology| | 4 × DC+ and 4 × DC- push-in tension clamp
terminals 2,5 – 10 mm²
| | 3-pin AC push-in tension clamp terminals 2.5 – 10 mm²
AC connection technology| 3-pin backup power push-in tension clamp terminals
1.5 – 10 mm²
| 2 × PE screw terminals 2.5 – 16 mm² and 3 × 2.5 – 10 mm²
Certificates and compliance with| | IEC 62109, IEC 62909, AS/NZS 4777.2, CEI
0-21,
standards 8| ABNT BNR 16149 und 16150, IEC 62116, IEC 61727 , G98/G99,
R25
Backup power functions 9| | PV Point and Full Backup
Producing country| | Austria
Life Cvcle Assessment| | According to ÖNORM EN ISO 14040 and 14044
(verified by employees of Fraunhofer IZM)
Efficiency| Maximum efficiency| %| 97.6| 97.6| 97.6
---|---|---|---|---|---
European efficiency (ηEU)| %| 96.8 97.0
97.1
MPP adjustment efficiency| %| > 99.9| > 99.9| > 99.9
Protective devices| DC isolation measurement| | Integrated
---|---|---|---
Overload performance| | Operating point adjustment, power limitation
DC disconnector| | Integrated
Reverse polarity protection| | Integrated
Interfaces| Wi-Fi / 2 × Ethernet LAN| | Fronius Solar.web, Modbus TCP
SunSpec, Fronius Solar API (JSON)
---|---|---|---
6 digital inputs6 digital inputs/outputs| | Interface to ripple control
receiver, energy management
Emergency shutdown (WSD)| | Integrated
Datalogger and web server| | Integrated
2 × RS485| | Modbus RTU SunSpec (third-party provider) / Fronius Smart Meter,
Battery (GEN24 Plus), Fronius Ohmpilot
- In line with IEC 62109-1. Option to retrofit surge protection device DC SPD type 1+2 for 2 MPP trackers available under the following item number: 4,240,313,CK
- You can find the current certificates under www.fronius.com/primo-gen24-plus cert
- Full Backup emergency power and battery function only available with GEN24 Plus
For further information on the availability of the inverters in your country, please visit www.fronius.com.
More information at www.fronius.com/gen24
References
- USA
- Canada
- Willkommen bei Fronius Schweiz
- Welcome to Fronius UK
- Welcome to Fronius Australia
- Fronius GEN24 - The versatile hybrid inverter - Solar Energy
- Download Search - Solar Energy - Fronius
- Willkommen bei Fronius Deutschland
- Welcome to Fronius India
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>