lbx Orb-B Orbital Shaker with Digital Screen User Manual

June 10, 2024
lbx

Orb-B Orbital Shaker with Digital Screen
User Manual

lbx Orb-B Orbital Shaker with Digital Screen -

Orb-B Orbital Shaker with Digital Screen

Preface
Users should read this Manual carefully, follow the instructions and procedures, and beware of all the cautions when using this instrument.
Service
In order to guarantee this equipment works safely and efficiently, it must have a regular maintenance. In case of any faults, do not try to repair it yourself. If help is needed, you can always contact your dealer or Labbox via www.labbox.com 

Please provide the customer care representative with the following information:

  • Serial number
  • Description of problem
  • Your contact information

Warranty
This instrument is warranted to be free from defects in materials and workmanship under normal use and service, for a period of 24 months from the date of invoice. The warranty is extended only to the original purchaser. It shall not apply to any product or parts which have been damaged on account of improper installation, improper connections, misuse, accident or abnormal conditions of operation.
For claim under the warranty please contact your supplier.

Safety Instructions

Warning!

  • Read the operating instructions carefully before use.
  • Ensure that only trained staff works with the instrument.

Protective ground contact!

  • Make sure that socket must be grounded (protective ground contact) before use.
  • When working, wear the personal guard to avoid the risk from:
    • Splashing liquids
    • Broken glass containers
  • Follow the safety instructions, guidelines and accident prevention regulations.
  • Do not touch the running parts, moving instrument care not rolling your fingers.
  • Set up the instrument in a spacious area on a stable, clean, non-slip, dry and fireproof surface. Do not operate the instrument in explosive atmospheres, with hazardous substances or under water.
  • If the instrument does not run smoothly, please decrease the motor speed.
  • Firmly secure the accessories and vessels in place to avoid damage or risk.
  • Preparation of samples may lead to dangerous flammable substances. Only process samples that will not react dangerous.
  • Use the standard accessories listed in the “accessories” section, and follow the instructions to use accessories to ensure safety. Please switch off the power before assembly of accessories, confirm the instrument and accessories are intact before switch on each time.
  • The instrument can only be opened by an expert, please switch off before use.
  • The voltage stated on the nameplate must correspond to the mains voltage.
  • Do not cover the instrument during running. Prevent the collision and extrusion to instrument and accessories.
  • Keep away from high magnetic field.

Proper Use

The instrument is designed for mixing in schools, laboratories or factories. This device is not suitable for using in residential areas or other constraints mentioned in Chapter1.
Not using the accessories recommended by the manufacturer, or failing to use the instructions, may end up causing an unsafe situation.

Inspection

3.1. Receiving Inspection
Unpack the equipment carefully and check for any damages which may have arisen during transport. Please contact manufacturer/supplier for technical support.
Note:
If there is any apparent damage to the system, please do not plug it into the power line.
3.2. Listing of Items
The package includes the following items:

Items Qty
Main unit 1
Power cable 1
User Manual 1

Function

4.1. Control

lbx Orb-B Orbital Shaker with Digital Screen -
Function

Items Descriptions
Mode switch button Shift speed and time setup mode
Parameter adjusting  knob Set speed and time by rotating the knob. Push

on/off to start/stop
rotating function
Speed display| Display the set speed values
Time display| Display the set time values
Power switch| Switch ON/OFF instrument.
Screw| Install the platform.

Operation

  • Place the instrument in safe and stable surface, ensure the required operating voltage and powersupply voltage matched.
  • Connect the power cable.
  • Install the platform.
  • Switch ON the instrument.
  • The instrument begins self-checking
  • When initialization is over, LED displays the last running values of speed and timer.
  • Rotate the speed control knob clockwise to set target speed:

a) Press the mode switch button to choose the speed or timer setup interface. When the character of LED display is flashing, rotate the parameter adjusting knob to ser the target parameter. Press the knob to start the motion.
b) During operation, motion can be stopped at any time by pressing the parameter adjusting knob. If the knob is pressed again, motion will start again and the timer will continue to countdown. When the timer reaches zero, the unit will be automatically halted
c) When the timer is set to be 00:00, it will run continuously.

  • Switch OFF the instrument.

If these operations above are normal, the instrument is ready to operate. If not, the instrument may be damaged during transportation, please contact technical support of manufacturer/supplier.
Note:
The speed value can be altered during shaking.

Faults

  • When switched ON, the instrument does not work
    -Check whether the power cable is connected
  • Motor speed cannot reach set value
    -Check whether it is overloaded

Maintenance and Cleaning

  • Proper maintenance can keep instruments working properly and lengthen its lifetime.
  • Do not spray cleanser into the instrument when cleaning.
  • Disconnect the power line when cleaning.
  • Only use recommended cleansers:
Dyes Isopropyl alcohol
Construction materials Water containing tenside / Isopropyl alcohol
Cosmetics Water containing tenside / Isopropyl alcohol
Foodstuffs Water containing tensive
Fuels Water containing tensive
  • Before using other method for cleaning or decontamination, the user must ascertain with the manufacturer that this method will not harm the instrument.
  • Wear the proper protective gloves during cleaning of the instrument.

Note:

• Electronic device cannot clean with cleanser.
• If you require maintenance service, must be cleaned the instrument in advance to avoid pollution of hazardous substances, and to send back into original packing.
• If the instrument will not use for a long time, please switch off and place in a dry, clean, room temperature and stable location.

Associated Standards and Regulations

Construction in accordance with the following safety standards:
EN 61010-1
UL 3101-1
CAN/CSA C22.2(1010-1)
EN 61010-2-10
Construction in accordance with the following EMC standards:
EN 61326-1
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Specifications

Items Specifications
Voltage [VAC] 100-240
Frequency [Hz] 50/60
Motor rating input[ W] 16
Motor rating output [W] 10
Shaking motion Orbital
Orbital diameter[mm] 20
Max. load capacity [Kg] 3
Motor type DC motor
Speed range[rpm] 0-200
Dimensions[W×H×D mm] 330 × 270 × 105
Operation type Continuous/timed
Time setting range 1min – 19h59 min
Weight[kg] 3,1
Permissible ambient temperature[℃] 5 – 40
Permissible relative humidity 80%
Protection class acc. DIN EN60529 IP21

Accessories

Please get in touch with our company to order the following accessories available for this device:

SHKB-A01-001|
---|---
SHKB-A02-001|
SHKB-A03-001|
SHKB-A04-001|
SHKB-A05-001|
SHKB-A00-001|
SHKU-025-001|
SHKU-050-001
SHKU-100-001
SHKU-250-001
SHKU-500-001
SHKU-A01-001|

www.labbox.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

lbx User Manuals

Related Manuals