lbx Orb-B Orbital Shaker with Digital Screen User Manual
- June 10, 2024
- lbx
Table of Contents
Orb-B Orbital Shaker with Digital Screen
User Manual
Orb-B Orbital Shaker with Digital Screen
Preface
Users should read this Manual carefully, follow the instructions and
procedures, and beware of all the cautions when using this instrument.
Service
In order to guarantee this equipment works safely and efficiently, it must
have a regular maintenance. In case of any faults, do not try to repair it
yourself. If help is needed, you can always contact your dealer or Labbox via
www.labbox.com
Please provide the customer care representative with the following information:
- Serial number
- Description of problem
- Your contact information
Warranty
This instrument is warranted to be free from defects in materials and
workmanship under normal use and service, for a period of 24 months from the
date of invoice. The warranty is extended only to the original purchaser. It
shall not apply to any product or parts which have been damaged on account of
improper installation, improper connections, misuse, accident or abnormal
conditions of operation.
For claim under the warranty please contact your supplier.
Safety Instructions
Warning!
- Read the operating instructions carefully before use.
- Ensure that only trained staff works with the instrument.
Protective ground contact!
- Make sure that socket must be grounded (protective ground contact) before use.
- When working, wear the personal guard to avoid the risk from:
- Splashing liquids
- Broken glass containers
- Follow the safety instructions, guidelines and accident prevention regulations.
- Do not touch the running parts, moving instrument care not rolling your fingers.
- Set up the instrument in a spacious area on a stable, clean, non-slip, dry and fireproof surface. Do not operate the instrument in explosive atmospheres, with hazardous substances or under water.
- If the instrument does not run smoothly, please decrease the motor speed.
- Firmly secure the accessories and vessels in place to avoid damage or risk.
- Preparation of samples may lead to dangerous flammable substances. Only process samples that will not react dangerous.
- Use the standard accessories listed in the “accessories” section, and follow the instructions to use accessories to ensure safety. Please switch off the power before assembly of accessories, confirm the instrument and accessories are intact before switch on each time.
- The instrument can only be opened by an expert, please switch off before use.
- The voltage stated on the nameplate must correspond to the mains voltage.
- Do not cover the instrument during running. Prevent the collision and extrusion to instrument and accessories.
- Keep away from high magnetic field.
Proper Use
The instrument is designed for mixing in schools, laboratories or factories.
This device is not suitable for using in residential areas or other
constraints mentioned in Chapter1.
Not using the accessories recommended by the manufacturer, or failing to use
the instructions, may end up causing an unsafe situation.
Inspection
3.1. Receiving Inspection
Unpack the equipment carefully and check for any damages which may have arisen
during transport. Please contact manufacturer/supplier for technical support.
Note:
If there is any apparent damage to the system, please do not plug it into the
power line.
3.2. Listing of Items
The package includes the following items:
Items | Qty |
---|---|
Main unit | 1 |
Power cable | 1 |
User Manual | 1 |
Function
4.1. Control
Items | Descriptions |
---|---|
Mode switch button | Shift speed and time setup mode |
Parameter adjusting knob | Set speed and time by rotating the knob. Push |
on/off to start/stop
rotating function
Speed display| Display the set speed values
Time display| Display the set time values
Power switch| Switch ON/OFF instrument.
Screw| Install the platform.
Operation
- Place the instrument in safe and stable surface, ensure the required operating voltage and powersupply voltage matched.
- Connect the power cable.
- Install the platform.
- Switch ON the instrument.
- The instrument begins self-checking
- When initialization is over, LED displays the last running values of speed and timer.
- Rotate the speed control knob clockwise to set target speed:
a) Press the mode switch button to choose the speed or timer setup interface.
When the character of LED display is flashing, rotate the parameter adjusting
knob to ser the target parameter. Press the knob to start the motion.
b) During operation, motion can be stopped at any time by pressing the
parameter adjusting knob. If the knob is pressed again, motion will start
again and the timer will continue to countdown. When the timer reaches zero,
the unit will be automatically halted
c) When the timer is set to be 00:00, it will run continuously.
- Switch OFF the instrument.
If these operations above are normal, the instrument is ready to operate. If
not, the instrument may be damaged during transportation, please contact
technical support of manufacturer/supplier.
Note:
The speed value can be altered during shaking.
Faults
- When switched ON, the instrument does not work
-Check whether the power cable is connected - Motor speed cannot reach set value
-Check whether it is overloaded
Maintenance and Cleaning
- Proper maintenance can keep instruments working properly and lengthen its lifetime.
- Do not spray cleanser into the instrument when cleaning.
- Disconnect the power line when cleaning.
- Only use recommended cleansers:
Dyes | Isopropyl alcohol |
---|---|
Construction materials | Water containing tenside / Isopropyl alcohol |
Cosmetics | Water containing tenside / Isopropyl alcohol |
Foodstuffs | Water containing tensive |
Fuels | Water containing tensive |
- Before using other method for cleaning or decontamination, the user must ascertain with the manufacturer that this method will not harm the instrument.
- Wear the proper protective gloves during cleaning of the instrument.
Note:
• Electronic device cannot clean with cleanser.
• If you require maintenance service, must be cleaned the instrument in
advance to avoid pollution of hazardous substances, and to send back into
original packing.
• If the instrument will not use for a long time, please switch off and place
in a dry, clean, room temperature and stable location.
Associated Standards and Regulations
Construction in accordance with the following safety standards:
EN 61010-1
UL 3101-1
CAN/CSA C22.2(1010-1)
EN 61010-2-10
Construction in accordance with the following EMC standards:
EN 61326-1
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Specifications
Items | Specifications |
---|---|
Voltage [VAC] | 100-240 |
Frequency [Hz] | 50/60 |
Motor rating input[ W] | 16 |
Motor rating output [W] | 10 |
Shaking motion | Orbital |
Orbital diameter[mm] | 20 |
Max. load capacity [Kg] | 3 |
Motor type | DC motor |
Speed range[rpm] | 0-200 |
Dimensions[W×H×D mm] | 330 × 270 × 105 |
Operation type | Continuous/timed |
Time setting range | 1min – 19h59 min |
Weight[kg] | 3,1 |
Permissible ambient temperature[℃] | 5 – 40 |
Permissible relative humidity | 80% |
Protection class acc. DIN EN60529 | IP21 |
Accessories
Please get in touch with our company to order the following accessories available for this device:
SHKB-A01-001|
---|---
SHKB-A02-001|
SHKB-A03-001|
SHKB-A04-001|
SHKB-A05-001|
SHKB-A00-001|
SHKU-025-001|
SHKU-050-001
SHKU-100-001
SHKU-250-001
SHKU-500-001
SHKU-A01-001|
References
Read User Manual Online (PDF format)