AMTAST AMT-105 In Out Alarm Thermometer User Manual

June 14, 2024
AMTAST

AMTAST AMT-105 In Out Alarm Thermometer

Product Information

The IN-OUT Alarm Thermometer AMT-105 is a digital thermometer designed to measure indoor and outdoor temperatures. It features an alarm function that can be set to notify the user when the temperature goes above or below a certain limit. The thermometer has a clear display for easy reading and comes with an outdoor sensor for accurate outdoor temperature measurement.

Product Specifications

  • Measuring range: N/A
  • Display accuracy: N/A
  • Display resolution: N/A
  • Display reading update: N/A
  • Battery: N/A
  • Display size: N/A
  • Battery Life: N/A
  • Outdoor sensor cord length: N/A
  • Product size: N/A
  • Accessories: N/A

Product Usage Instructions

Installation

  1. Open the battery cover.
  2. Install the battery with correct polarity positioning.
  3. Close the battery cover.
  4. Extend the outdoor sensor cord and mount the outdoor sensor with the supplied sensor holder on the desired outdoor space.
  5. Choose a space away from direct sunlight, rain, or extreme heat and wipe the space clean.
  6. Use the supplied Velcro magic tape to attach the thermometer onto the space or attach the thermometer onto an iron substance directly.
  7. Peel off the display protective sheet.

Operation

  1. Press the / button on the back to select the temperature unit.
  2. Maximum / minimum reading memory:
    • Press Max/Min to display the maximum measured value (MAX).
    • Press the button once more to display the minimum measured value (MIN).
    • Press the button again to return to normal display.
    • Press and hold Max/Min for about 2 seconds to reset the memory to the current reading.
  3. Outdoor sensor temperature display:
    • Press IN/OUT to display the outdoor sensor temperature.
    • Press the button again to display normally.
  4. High / low temperature alarm setting (for outdoor sensor only):
    • Press and hold for about 2 seconds, the HIGH and OUT icons will flash.
    • Press / on the back to set the alarm high limit.
    • Press again, the LOW and OUT icons will flash.
    • Press / to set the alarm low limit.
    • Press once more to finish setting and display normally.

During limits setting, holding down / will advance the value automatically. If the outdoor sensor reading is out of the set limit, then the alarm will sound.

  1. ALARM off or on:
    • Press to switch off the alarm (AL off).
    • Press again to switch the alarm on (AL on).

FAQ

Q: What is the measuring range of the thermometer?
A: The measuring range of the thermometer is not specified in the user manual.

Q: How long does the battery last?
A: The battery life is not specified in the user manual.

FEATURES

  • Outdoor high / low temperature alarm setting
  • Maximum / minimum temperature memory
  • Indoor / Outdoor temperature display
  • ℃ / ℉ exchange
  • Large and clear digital display
  • Waterproof outdoor sensor
  • Magnetic attachment
  • Velcro magic tape fixing

SPECIFICATION




Measuring range

| -20 ~ 70℃ / -4 ~ 122℉ (room temperature)

-50 ~ 70℃ / -58 ~ 158℉

(outdoor temperature)

---|---
Display accuracy| ±1℃ / ±1.8℉ over full range
Display resolution| 0.1
Display reading update| 10 seconds
Battery| 1.5 volt, size AAA or equivalent X 1 piece
Display size| 47 (W) X 21(H) mm
Battery Life| About 1 year
Outdoor sensor cord length| 2 meter
Product size| 63(W) X 63(H) X 15(D) mm



Accessories

| 1)     Sensor holder X 1 piece

2)     Battery X 1 piece

3)     Velcro magic tape X 1 piece

INSTALLATION

  1. Open battery cover.
  2. Install battery with correct polarity positioning.
  3. Close battery cover.
  4. Extend the outdoor sensor cord and mount the outdoor sensor with the supplied sensor holder on desired outdoor space.
  5. Choose a space away from direct sunlight, rain or extreme heat and wipe the space clean.
  6. Use the supplied Velcro magic tape to attach thermometer onto the space or attach thermometer onto iron substance directly.
  7. Peel off display protective sheet.

OPERATION

  1. ℃ / ℉ Exchange
    Press【℃ / ℉】on the back to select temperature unit.

  2. Maximum / minimum reading memory

  3. Press【Max/Min】to display maximum measured value (MAX), press the button once more to display minimum measured value (MIN), press the button again to return to normal display.

  4. Press and hold 【Max/Min】for about 2 seconds to reset memory to current reading.

  5. Outdoor sensor temperature display

  6. a. Press【IN/OUT】to display outdoor sensor temperature.

  7. b. Press the button again to display normally.

  8. High / low temperature alarm setting (for outdoor sensor only)

  9. a. Press and hold【 】for about 2 seconds, the HIGH and OUT icons will flash.

  10. b. Press【℃ / ℉】on the back to set alarm high limit.

  11. c. Press【 】again, the LOW and OUT icons will flash.

  12. d. Press【℃ / ℉】to set alarm low limit.

  13. e. Press【 】once more to finish setting and display normallymore to display minimum measured value (MIN), press the button again to return to normal display.
    During limits setting, holding down【℃ / ℉】will advance the value automatically. If the outdoor sensor reading is out of the set limit then the alarm will sound.

  14. ALARM off or on.

  15. a. Press【 】to switch off alarm (AL off).

  16. b. Press【 】again to switch alarm on (AL on).m high limit.

Read User Manual Online (PDF format)