HOLOPHANE HARP Series Discontinued MH Post Top
Product Information
The Harp Series is a discontinued outdoor lighting fixture available in two versions: 3 x 4 tall tenon mount version and 2 threaded pipe mount version. The luminaire is designed for outdoor use and requires installation by a qualified professional.
Important Safety Instructions
- Read and follow all instructions carefully before attempting to install or maintain the fixture.
- All work must be done by qualified personnel.
- Disconnect power from the fixture before installing or maintaining the fixture.
- Failure to follow these warnings may result in death, injury, or significant property damage.
Alternate Information Sources
If you require additional information, contact the Holophane Field Service Department at:
- P.O. Box 3004
- Newark, OH 43058-3004
- Phone: 866-759-1577
Product Usage Instructions
The following instructions are for the installation and maintenance of the Harp Series fixture.
Product Installation
Tools and Materials Required
Description | Use |
---|---|
1/8 hex wrench | Mounting set screws |
3/8 nutdriver or medium flat screwdriver | Ballast assembly plate and wireway |
cover
Torque wrench| N/A
7/16 nutdriver or socket| Ballast assembly cover
1/4 nutdriver or medium flat screwdriver| Ballast assembly plate
Fixture Installation
- Feed supply leads from the pole through the wireway hole.
- Place and level the luminaire on the pole. On units that mount to a 3O.D. X 4 tall tenon, alternately tighten the (6) set screws to 10-12 foot pounds. See Figure 1. On units that mount to a 2 threaded pipe, install the pipe nut (not supplied) used to secure the unit.
- Connect the electrical supply wires to the terminal block in the bottom of the housing. The terminals are marked L1 (Line 1). G (Ground), and L2 (Line 2). If one of the supply lines is electrically neutral, it should be connected to terminal L2. Refer to Figure 2.
- Holding the ballast assembly/top cover in one hand, use the other hand to connect the male wiring harness connector to the female wiring harness connector. See Figure 2.
- Gently place ballast assembly into chamber of housing.
- Tighten (3) set screws on ballast assembly/top cover. See Figure 2.
- Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
- Install the proper lamp type. Tighten the lamp carefully but securely.
- Close lamp chamber by swinging up the refractor and tightening the refractor door screw.
- Energize the luminaire. Check for proper operation.
Product Maintenance
Relamping and Cleaning
- Wipe off exterior dirt and debris.
- Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
- Remove lamp.
- Wipe out the refractor interior with a clean dry cloth.
- Install new lamp of correct wattage and type. Tighten the lamp carefully but securely.
- Close lamp chamber by swinging up the refractor and tightening the refractor door screw.
- Energize the luminaire. Check for proper operation.
IMPORTANT SAFETY INSTRUCTIONS
WARNING – READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL
OR MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY QUALIFIED PERSONNEL.
WARNING – BE CERTAIN THAT ALL ELECTRICAL POWER IS DISCONNECTED FROM THE
FIXTURE BEFORE INSTALLING OR MAINTAINING THE FIXTURE.
WARNING – FOLLOW LAMP MANUFACTURER’S OPERATING AND MAINTENANCE
INSTRUCTIONS. FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN DEATH, INJURY OR
SIGNIFICANT PROPERTY DAMAGE.
INTRODUCTION
Product Description
- The Harp luminaires have been designed to distribute specific patterns of light on the surface below. All optics have street side orientation embossed on the flange of the refractor.
- The Harp luminaire is designed for easy maintenance.
- The lamp can be easily accessed by loosening a screw and swinging down the refractor.
- Electrical components are mounted on an easily removable ballast assembly plate.
Alternate Information Sources
- Holophane
- Field Service Department
- P.O. Box 3004
- Newark, OH 43058-3004 866-759-1577
INSTALLATION
Tools and Material Required
Table 1. Installation Tools and Materials
DESCRIPTION USE
- 1/8″ hex wrench Set screws (mounting)
- 3/8″ nutdriver or medium Ballast assembly plate flat screwdriver and wireway cover Torque wrench Set screws
- 7/16″ nutdriver or socket Ballast Assembly Cover
- 1/4″ nutdriver or medium Ballast assembly Plate flat screwdriver
Fixture Installation
-
Feed supply leads from the pole through the wireway hole
-
Place and level the luminaire on the pole. On units that mount to a 3″O.D. X 4″ tall tenon, alternately tighten the (6) set screws to 10-12 foot pounds. See Figure 1. On units that mount to a 2″ threaded pipe, install the pipe nut (not supplied) used to secure the unit.2.2.3 Connect the electrical supply wires to the terminal block in the bottom of the housing. The terminals are marked “L1” (Line 1). “G” (Ground), and “L2” (Line 2). If one of the supply lines is electrically neutral, it should be connected to terminal “L2”. Refer to Figure 2.
-
Connect the electrical supply wires to the terminal block in the bottom of the housing. The terminals are marked “L1” (Line 1). “G” (Ground), and “L2” (Line 2). If one of the supply lines is electrically neutral, it should be connected to terminal “L2”. Refer to Figure 2.
-
Holding the ballast assembly/top cover in one hand, use the other hand to connect the male wiring harness connector to the female wiring harness connector. See Figure 2.
-
Gently place ballast assembly into chamber of housing.
-
Tighten (3) set screws on ballast assembly/top cover. See Figure 2.
-
Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
OPTICS ORIENTATION NOTES
Some of the fixtures in this series are equipped with optical components that produce distributions of light that are not symmetric and are intended to be aimed by orienting the prismatic refractor a specific direction. The “Street Side” marking on the refractor should be pointed toward the street. -
Install the proper lamp type. Tighten the lamp carefully but securely.
-
Close lamp chamber by swinging up the refractor and tightening the refractor door screw.
-
Energize the luminaire. Check for proper operation.
MAINTENANCE
Relamping and Cleaning
- Wipe off exterior dirt and debris.
- Open lamp chamber by loosening the refractor door screw and swing down refractor. Refer to Figure 1.
- Remove lamp.
- Wipe out the refractor interior with a clean dry cloth.
- Install new lamp of correct wattage and type. Tighten the lamp carefully but securely.
- Close lamp chamber by swinging up the refractor and tightening the refractor door screw.
- Energize the luminaire. Check for proper operation.
Replacement Ballast Assembly
- Loosen (3) set screws on ballast assembly/top cover. Refer to Figure 2.
- Pull up ballast assembly/top cover with one hand and use other hand to disconnect the male wiring harness connector.
- Flip assembly upside down, loosen the (3) keyway screws and turn ballast plate assembly clockwise to disengage.
- Unpack replacement ballast assembly. Check voltage leads.
- Place the top of the ballast assembly on the bottom of the top cover. Rotate ballast assembly counter-clockwise until the keyway screws engage. Tighten the (3) keyway screws.
- Flip ballast assembly/top cover 180 degrees, connect the male wiring harness connector to the female wiring harness connector and gently place assembly down into housing.
- Tighten (3) set screws.
- Energize the luminaire. Check for proper operation.
WARRANTY
LIMITED WARRANTY AND LIMITATION OF LIABILITY
The Holophane limited warranty and limitation of liability is published in the “Terms and Conditions” section of the current Holophane buyer’s guide, and is available from your local Holophane sales representative.
Acuity Lighting Group, Inc
- 214 Oakwood Ave., Newark, OH 43055
- IM-136-B 4/03 ©2003 Acuity Lighting Group Inc.
- Visit our web site at www.holophane.com
References