HOLOPHANE RSL-350 Series Residential Street Light Installation Guide
- June 9, 2024
- HOLOPHANE
Table of Contents
HOLOPHANE RSL-350 Series Residential Street Light
IMPORTANT SAFETY INSTRUCTIONS
- WARNING – READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OR MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY QUALIFIED PERSONNEL.
- WARNING – BE CERTAIN THAT ALL ELECTRICAL POWER IS DISCONNECTED FROM THE FIXTURE BEFORE INSTALLING OR MAINTAINING THE FIXTURE.
- WARNING – FOLLOW LAMP MANUFACTURER’S OPERATING AND MAINTENANCE INSTRUCTIONS. FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE
INTRODUCTION
Product Description
- The RSL-350 is designed to include most of the standard low wattage, medium- and mogul-base HID lamps currently available.
- The fixtures utilize a precision optical system to maximize post spacings. Gaskets located above and below the refractor create a sealed optical chamber.
- The RSL-350 is designed to mount on a 3 inch O.D. post tenon.
Alternate Information Sources.
Holophane Field Service Department P.O. Box 3004 Newark, OH 43058-3004 866-759-1577
INSTALLATION
Tools and Material Required.
Fixture Installation.
-
Place and level the luminaire on the post top tenon. See Figure 1. If the unit is supplied with a photocontrol, the photo eye should be oriented in a northerly direction. Alternate tightening of the set screws will assist in leveling and insuring proper attachment of the fixture. Tighten the set screws to 10-12 ft-lbs.
-
Remove the wire way cover by removing the two screws.
-
Standard Units: Connect the electrical supply wires to the luminaire wires. Follow approved wiring techniques. Connect incoming ground wire to ground wire attached to inside of wiring chamber. Connect incoming common wire to wire marked COM from the ballast. If a single voltage ballast is used, connect the remaining wire to the incoming supply line. Note: Lead may need to be stripped. If a multivolt ballast is used, find the correct voltage number marked on one of the remaining wires and make the connection. Carefully, place connections in wiring chamber for future access. See Figure 1.
Twist Lock Photocontrol Units: See Figures 3. Connect the electrical supply wires to the luminaire wires. Follow approved wiring techniques. Connect incoming ground wire to ground wire attached to inside of wiring chamber. Connect incoming common wire to wire marked COM from the ballast. If a single voltage unit is used, connect the black wire from the photocontrol to the incoming line lead. If a multiple voltage ballast is used, connect the red lead from the photocontrol to the appropriate voltage ballast lead. Connect the black lead from the photocontrol to the incoming supply line lead. Note: Lead may need to be stripped. Photocontrol Units: Carefully, place connections in wiring chamber for future access. -
Replace wire way cover. Reinstall and tighten screws.
-
Remove the two retaining nuts and remove the top cover by lifting it straight up.
Figure 2 -
Twist lock Photocontrol Units: Disconnect the
photocontrol electrical connector and remove the wires from the wire support. See Figure 3 -
Install the proper lamp type. Tighten the lamp carefully but securely.
OPTICS ORIENTATION NOTES
Some of the fixtures in this series are equipped with optical components that produce distributions of light that are not symmetric and are intended to be aimed by orienting the prismatic refractor a specific direction. The “Street Side” marking on the refractor should be pointed toward the street. -
Orient the refractor by locating the markings on the refractor flange. Position the “street side” marking toward the street and align the “rib” marking with the ribs of the housing.
-
Twist lock Photocontrol Units: Place photocontrol
wires into wire support. Reconnect the photocontrol electrical connector. See Figure 3 -
Re-install the top cover by placing it over the ribs and aligning the holes in the top cover with the threaded studs on the ribs. Reinstall the two retaining nuts.
-
Twist lock Photocontrol Units: Remove the plastic cap from the top of the unit. Loosen two screws on the photocontrol receptacle. Rotate the receptacle to point the arrow marked “N” in a direction that is generally North. Tighten the two screws on the photocontrol receptacle. Install a twist-lock type photocontrol in to the receptacle.
-
Energize the fixture and check for proper operation.
Figure 3
Optional Equipment Installation
- Scroll – Attach scroll to ballast housing below wire way cover, replace upper set screws with 3/8 set screws in kit. See Figure 4.
- Filigree – Remove two retaining nuts from top cover and place Filigree over the studs. Reinstall the two retaining nuts. See Figure 4.
Figure 4
MAINTENANCE
Re-lamping and Cleaning
-
Wipe off exterior dirt and debris from the plastic surfaces using a soft, clean cloth.
CAUTION
DO NOT USE ABRASIVE CLEANSERS ON OPTICAL SURFACES. THEIR USE MAY RESULT IN THE LOSS OF OPTICAL EFFICIENCY. -
Loosen the two top cover retaining nuts.. Lift the top cover straight up. Note the orientation of the “Street Side” marking on the refractor. See Fig. 1.
Twist lock Photocontrol Units: Disconnect the photocontrol electrical connector and remove the wires from the wire support. See Figure 3.
Remove the lamp and dispose of it in a safe and proper manner.
Install the proper lamp type. Tighten the lamp carefully but securely.
Twist lock Photocontrol Units: Place photocontrol wires into wire support. Reconnect the photocontrol electrical connector. See Figure 3.
Re-install the top cover by placing it over the ribs and aligning the holes in the top cover with the threaded studs on the ribs. Reinstall the two retaining nuts
Energize the fixture and check for proper operation.
Electrical Component Replacement
-
Loosen the two top cover retaining nuts.. Lift the top cover straight up. Note the orientation of the “Street Side” marking on the refractor. See Fig. 1.
-
Twist lock Photocontrol Units: Disconnect the photocontrol electrical connector and remove the wires from the wire support. See Figure 3.
-
Remove the lamp.
-
Remove refractor.
-
Loosen screws to wire way cover and remove wire way cover.
-
Tag and disconnect common and line leads.
-
Loosen the two keyway screws and turn ballast plate assembly clockwise to disengage. Remove the ballast assembly. See Figure 2.
If a complete replacement electrical module is being used, skip to step 3.2.10 -
Tag all leads that will be disconnected and note the orientation and position of all components that will be replaced and the fasteners holding them. Remove the component(s) to be replaced.
-
Use components supplied by Holophane. Place the new components exactly as were the original components and reuse the original fasteners to secure them. Check for pinched wires before tightening down the replacement components. Tighten all fasteners firmly. Bundle and secure the wiring in a manner similar to the way it was originally secured.
-
Set replacement ballast assembly down into casting. Rotate counter clockwise and tighten the two keyway screws. See Figure 2.
-
Reconnect electrical connections in accordance with tags and approved wiring practices. Replace wire way cover. Tighten screws.
-
Gently move ballast plate assembly to an upright position and place the assembly over the two keyway screws and turn counterclockwise into position. Tighten screws.
-
Replace the refractor. Orient the refractor by locating the markings on the refractor flange. Position the “street side” marking toward the street and align the “rib” marking with the ribs of the housing.
-
Replace correct wattage and type lamp.
-
Twist lock Photocontrol Units: Place
photocontrol wires into wire support. Reconnect the photocontrol electrical connector. See Figure 3. -
Close top cover and engage latch.
-
Energize the luminaire. Check for proper operation.
LIMITED WARRANTY
LIMITATION OF LIABILITY
The Holophane limited warranty and limitation of liability is published in the “Terms and Conditions” section of the current Holophane buyer’s guide, and is available from your local Holophane sales representative.
Acuity Lighting Group, Inc. 214 Oakwood Ave., Newark, OH 43055 IM-177 7/02 ©2002 Acuity Lighting Group Inc. Visit our web site at www.holophane.com
Printed in USA
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>