ZALMAN LXII Series Power Supply Units User Manual

June 4, 2024
ZALMAN

ZALMAN logo LXII SERIES
POWER SUPPLY UNITS
500W, 600W, 700W
User’s Manual PSU Warranty Program: http://zalman.com/psu.html

Z was Developed and designed by ZALMAN in Korea.
This product ts protected by ZALMAN’s pending or registered patents
To ensure safe and easy installation, Please read the following precautions. www.zalman.com 

Warnings and Safety Precautions

WARNING Neglecting the following may cause serious injury or death.

  • Opening the cover of the product while the power cord is plugged into an outlet may cause electrocution or critical damage to the product.

  • Handling the power cord with wet hands may cause electrocution.

  • Inserting fingers or metallic objects into the cooling fan may cause injury or electrocution.
    CAUTION Neglecting the following may cause minor injuries, degrade product conditions or cause malfunction.

  • Operating the product in an extremely cold or hot environment can degrade product performance and lifespan.

  • Exposure to liquids may cause malfunction.

  • Operation in a humid or non-ventilated environment may reduce product lifespan.

  • Plugging the main power connector P1 into the motherboard while the product is connected to the AC power source may cause damage to the motherboard.

  • Make sure that the connectors are connected to their designated locations, and that the connectors are not oriented in the wrong direction when connecting the DC output connectors.

  • Please use gloves to prevent injuries during installation.

  • Product designs and specifications may be revised without prior notification to improve quality and performance.

WARNING This product is designed for computer use only, such as offices, multimedia, the Internet, and games. Using this product in any other application will void the warranty. The power supply unit(PSU) is for integration into a computer system and is not intended for external or outdoor usage. Please note that Full Modular PSU’s warranty is applicable to the power supply unit ONLY and does not include accessories such as, power cables, connectors and etc. A non-Modular warranty is applicable to PSU and its power cables. If you have any questions, please ask a specialist for help.
DISCLAIMER
Zalman Tech Co., Ltd. is not responsible for any damages due to external causes, including but not limited to, improper use, problems with electrical power, accident, neglect, alteration, repair, improper installation, or improper testing.

Components

ZALMAN LXII Series Power Supply Units - fig

 ZM500-LXII Specifications

  1. Electrical & Physical Specifications

AC Input Range| Voltage| 200-240VAC ±10%| Vout| Output Load Rating| Combined
Power
---|---|---|---|---|---
Frequency| 50-60Hz ±3%| Imin| Imax| Speak
AC Input Current| Current| SA| +3.3V| 0.1A| 14A| | 110W| 500W
+5V| 0.2A| 16A|
PFC Type| Active PFC| +12V| 0.2A| 38A| | 456W
Power Factor
Correction| Max 99%| -12V| 0.0A| 0.3A| | 3.6W
Inrush Current
Limit| 230VAC| Max 50A| +SVSB| 0.0A| 2.5A| | 12.5W
Ambient Temperature
Efficiency| Max 85% @ 230VAC, Typical load| Operation| 0 — +40°C
DC Output
Volta ge
Regulation| Vout| Regulation Range| At Full  Load| Storage| -20 — +70°C
+3.3VDC| ±5%| +3.14 — +3.47V| Ambient Humidity
+5VDC| ±5%| +4.75 — +5.25V| Operation| 5% — 95% RH
+12VDC| ±5%| +11.4 — +12.6V| Storage| 5% — 95% RH
-12VDC| ±10%| -10.8 — -13.0V| Dimensions| 150(L) X 140(W) X 86(H) mm
+SVSB| ±5%| +4.75 — +5.25V| Weight| 1.94Kg
DC Output
Ri pple
& Noise| Vout| Standard Range| At Load| Protection Functions
+3.3VDC| 50mV| Over-Temperature Protection(OTP)
+5VDC| 50mV| Full Over-Voltage Protection (OVP)
+12VDC| 120mV| Over-Power Protection (OPP)
-12VDC| 120mV| Short-Circuit Protection (SCP)
+SVSB| 50mV|

Cable Specifications

ZALMAN LXII Series Power Supply Units - fig 1

AC Input Range| Voltage| 200-240VAC ±10%| Vout| Output Load Rating| Combined Power
---|---|---|---|---|---
Imin| Imax| Ipeak
Frequency| 50-60Hz ±3%
AC Input Current| Current| 5A| +3.3V| 0.1A| 20A| | 120W| 600W
+5V| 0.2A| 20A|
PFC Type| | Active PFC| +12V| 0.2A| 46A| | 552W
Power Factor
Correction| Max 99%| -12V| 0.0A| 0.3A| | 3.6W
Inrush Current
Limit| 230VAC| Max 50A| +5VSB| 0.0A| 2.5A| | 12.5W
Ambient Temperature
Efficiency| Max 85% @ 230VAC, Typical load| Operation| 0 — +40°C
DC Output
Voltage
Regulation| Vout| Regulation Range| At
Full
Load| Storage| -20 — +70°C
Ambient Humidity
+3.3VDC| ±5%| +3.14 — +3.47V
Operation| 5% — 95% RH
+5VDC| ±5%| +4.75 — +5.25V
Storage| 5% — 95% RH
+12VDC| ±5%| +11.4 — +12.6V
Dimensions| 150(L) X 140(W) X 86(H) mm
-12VDC| ±10%| -10.8 — -13.0V
Weight| 1.98Kg
+5VSB| ±5%| +4.75 — +5.25V
DC Output
Ripple
& Noise| Vout| Standard Range| At Full
Load| Protection Functions
Over-Temperature Protection(OTP)
+3.3VDC| 50mV
Over-Voltage Protection (OVP)
+5VDC| 50mV
Over-Power Protection (OPP)
+12VDC| 120mV
Short-Circuit Protection (SCP)
-12VDC| 120mV
+5VSB| 50mV

ZALMAN LXII Series Power Supply Units - fig2

AC Input Range| Voltage| 200-240VAC ±10%| Vout| Output Load Rating| Combined Power
---|---|---|---|---|---
Frequency| 50-60Hz ±3%| Imin| Imax| Ipeak
AC Input Current| Current| 5A| +3.3V| 0.1A| 20A| | 120W| 700W
+5V| 0.2A| 20A|
PFC Type| | Active PFC| +12V| 0.2A| 54A| | 648W
Power Factor
Correction| Max 99%| -12V| 0.0A| 0.3A| | 3.6W
Inrush Current
Limit| 230VAC| Max 50A| +5VSB| 0.0A| 2.5A| | 12.5W
Ambient Temperature
Efficiency| Max 85% @ 230VAC, Typical load| Operation| 0 — +40°C
DC Output
Volta ge
Regulation| Vout| Regulation Range| At
Full  Load| Storage| -20 — + 70°C
+3.3VDC| ±5%| +3.14 — +3.47V
Ambient Humidity
+5VDC| ±5%| +4.75 — +5.25V| Operation| 5% — 95% RH
+12VDC| ±5%| +11.4 — +12.6V| Storage| 5% — 95% RH
-12VDC| ±10%| -10.8 — -13.0V| Dimensions| 150(L) X 140(W) X 86(H) mm
+5VSB| ±5%| +4.75 — +5.25V| Weight| 2.08Kg
DC Output Rile
pp & Noise| Vout| Standard Range| At
Load| Protection Functions
+3.3VDC| 50mV| Over-Temperature Protection(OTP)
+5VDC| 50mV| Full Over-Voltage Protection (OVP)
+12VDC| 120mV| Over-Power Protection (OPP)
-12VDC| 120mV| Short-Circuit Protection (SCP)
+5VSB| 50mV|

ZALMAN LXII Series Power Supply Units - fig3

AC Input Range| Voltage| 200-240VAC ±10%| Vout| Output Load Rating| Combined Power
---|---|---|---|---|---
Frequency| 50-60Hz ±3%| Imin| Imax| Ipeak
AC Input Current| Current| 5A| +3.3V| 0.1A| 20A| | 120W| 700W
+5V| 0.2A| 20A|
PFC Type| | Active PFC| +12V| 0.2A| 54A| | 648W
Power Factor
Correction| Max 99%| -12V| 0.0A| 0.3A| | 3.6W
Inrush Current
Limit| 230VAC| Max 50A| +5VSB| 0.0A| 2.5A| | 12.5W
Ambient Temperature
Efficiency| Max 85% @ 230VAC, Typical load| Operation| 0 — +40°C
DC Output Voltage Regulation| Vout| Regulation Range| At
Full
Load| Storage| -20 — + 70°C
+3.3VDC| ±5%| +3.14 — +3.47V| Ambient Humidity
+5VDC| ±5%| +4.75 — +5.25V| Operation| 5% — 95% RH
+12VDC| ±5%| +11.4 — +12.6V| Storage| 5% — 95% RH
-12VDC| ±10%| -10.8 — -13.0V| Dimensions| 150(L) X 140(W) X 86(H) mm
+5VSB| ±5%| +4.75 — +5.25V| Weight| 2.08Kg
DC Output Rile
pp & Noise| Vout| Standard Range| At Load| Protection Functions
+3.3VDC| 50mV| Over-Temperature Protection(OTP)
+5VDC| 50mV| Full Over-Voltage Protection (OVP)
+12VDC| 120mV| Over-Power Protection (OPP)
-12VDC| 120mV| Short-Circuit Protection (SCP)
+5VSB| 50mV|