ALTRAD BELLE MINIMIX 130 Cement Mixer User Manual
- June 9, 2024
- ALTRAD
Table of Contents
BELLE
MINIMIX 130 CEMENT MIXER
Operators Manual
2 UKCA Declaration of Conformity
3 – 7 EC/EU Declaration of Conformity
BELLE MINIMIX 130 Cement Mixer
Declaration Of Conformity (DOC)
We, Altrad Belle, Sheen, Nr. Buxton, Derbyshire, SK17 0EU, GB declare that
the DoC is issued under our sole responsibility and belongs to the followings
product(s):
PRODUCT TYPE ………
MODEL…………………….
SERIAL No……………….
DATE OF MANUFACTURE SOUND POWER LEVEL MEASURED / ………………..(GUARANTEED)
WEIGHT…………………..| See information on sticker above
---|---
Object of the Declaration:
Portable, professional ‘Tip-Up’ style cement mixer for mixing concrete and
mortar.
The object of the declaration described above is in conformity with the
relevant Statutory
Requirements:
– 2008 No. 1597 | Supply of Machinery (Safety) Regulations 2008 |
---|---|
– 2001 No. 1701 | Noise Emission in the Environment by Equipment for use |
Outdoors Regulations 2001
– 2016 No. 1091| Electromagnetic Compatibility Regulations 2016
The following designated standards and technical specifications have been applied:
– EN ISO 12100:2010 | Supply of Machinery (Safety) Regulations 2008 |
---|---|
– EN 61029-1:2009 | Safety of transportable motor-operated electric tools. |
– ISO 3744:2010 | Acoustics — Determination of sound power levels and sound |
energy levels of noise sources using sound pressure
Technical Files are held by Ray Neilson at the Altrad Belle address stated
above:-
Place of Declaration:-
Sheen,
Nr. Buxton,
Derbyshire,
SK17 0EU,
UK
Date of Declaration:-
February 2022
Signed by:
Managing Director
On behalf of Altrad Belle
Sheen, Derbyshire, UK
EC Declaration Of Conformity (DOC)
We, Altrad Belle, Sheen, Nr. Buxton, Derbyshire, SK17 0EU, GB declare that
the DoC is issued under our sole responsibility and belongs to the followings
product(s):
PRODUCT TYPE ………
MODEL…………………….
SERIAL No……………….
DATE OF MANUFACTURE SOUND POWER LEVEL MEASURED / ………………..(GUARANTEED)
WEIGHT…………………..| See information on sticker above
---|---
Object of the Declaration:
Portable, professional ‘Tip-Up’ style cement mixer for mixing concrete and
mortar.
The object of the declaration described above is in conformity with the
relevant
Union Harmonisation Legislation:
– 2006/42/EC – New machinery directive
– 2000/14/EC – Noise – equipment for use outdoors
The following harmonised standards and technical specifications have been
applied:
– EN ISO 12100:2010 Safety of machinery
– EN 61029-1:2009 Safety of transportable motor-operated electric tools.
– ISO 3744:2010 Acoustics — Determination of sound power levels and sound
energy levels of noise sources using sound pressure
Technical Files are held by Hugues Menager at the following address:Altrad
(Group Holding), 125 Rue du Mas Carbonnier, 34000, Montpellier, France.
Signed by:
Managing Director
On behalf of Altrad Belle, Sheen, Derbyshire, UK
Place of Declaration:-
Sheen, Nr. Buxton, Derbyshire, SK17 0EU, UK
Date of Declaration:February
2022
EU Declaration Of Conformity (DOC)
We, Altrad Belle, Sheen, Nr. Buxton, Derbyshire, SK17 0EU, GB declare that
the DoC is issued under our sole responsibility and belongs to the followings
product(s):
PRODUCT TYPE ………
MODEL…………………….
SERIAL No……………….
DATE OF MANUFACTURE SOUND POWER LEVEL MEASURED / ………………..(GUARANTEED)
WEIGHT…………………..| See information on sticker above
---|---
Object of the Declaration:
Portable, professional ‘Tip-Up’ style cement mixer for mixing concrete and
mortar.
The object of the declaration described above is in conformity with the
relevant
Union Harmonisation Legislation:
– 2006/42/EC – New machinery directive
– 2000/14/EC – Noise – equipment for use outdoors
The following harmonised standards and technical specifications have been
applied:
– EN ISO 12100:2010 Safety of machinery
– EN 61029-1:2009 Safety of transportable motor-operated electric tools.
– ISO 3744:2010 Acoustics — Determination of sound power levels and sound
energy levels of noise sources using sound pressure
Technical Files are held by Hugues Menager at the following address:Altrad
(Group Holding), 125 Rue du Mas Carbonnier, 34000, Montpellier, France.
Signed by:
Managing Director
On behalf of Altrad Belle, Sheen, Derbyshire, UK
Place of Declaration:-
Sheen, Nr. Buxton, Derbyshire, SK17 0EU, UK
Date of Declaration:February
2022
Introduction
Read this manual, carefully, observing all operating and safety instructions
before, during and after using your machine, and maintain you machine in good
working order.
Congratulations on your purchase of this quality concrete mixer from the
Altrad Belle Range.
This machine is manufactured to conform to the EEC directives currently in
force, is issued with a declaration of conformity and therefore displays the
CE mark, applicable in territories where they are enforced. Retain this manual
with your machine for future reference.
SAFETY AND ACCIDENT PREVENTION
Operation Instructions
All persons who apply, assemble, operate, start, control, maintain or repair
this machine, must read and understand the operating instructions.
Owner Responsibility:
STORAGE
When not in use, store in a dry, locked place. Keep away from children.
Operation for the Intended Purpose :
Mixers are intended for the production of concrete, mortar and plaster. The
mixer must be used for mixers must not be used in an explosive atmosphere.
MAINTENANCE AND REPAIRS
When maintaining this machine only the manufacturers original replacement
parts may be used. The user will lose any possible claims if replacement parts
used are other than the makers original replacement parts.
Only authorised persons should repair the mixer, and within the requirements
of the CE mark (where Any maintenance and repairs carried out, to any of the
electric components
ATTENTION!
Make a note of the serial numbers of your machine and always quote them in any
communication with a Altrad Belle Dealer.
ENGINE SERIAL NUMBER
MACHINE SERIAL NUMBER
Safety Instructions
Before starting the mixer
Check that all guards are in position and correctly fitted.
DO NOT wear loose clothing or jewellery that may become entangled in the
workings of this machine.
Suitable clothing as follows should meet relevant EEC/local safety
standards: overalls, work boots, goggles, face mask, gloves and ear defenders
etc.
DO NOT tip mixer onto the drum mouth when motor is running.
Ensure that any trailing cable is protected against damage and not
liable to be tripped over or trapped underneath the mixer.
We recommend the use of an Residual Current Device on 230v electrics.
** Remove all packaging material before operating.
When operating the mixer
** Keep unauthorised persons away from mixing drum.
Keep area around the mixer clear of obstructions which could cause
persons to fall onto moving parts.
Always ensure mixer is on level ground before mixing.
DO become familiar with the controls before operating this machine.
DO ensure that all guards are fitted in the correct position.
DO replace any wom/damaged warning decals.
DO ensure the drum is rotating while emptying the mixer.
DO always switch off and remove the plug from the socket if leaving the
machine unattended.
DO NOT use as a wheel barrow. Disconnect from power supply before
moving.
** BEWARE of the Danger Zones & Hot Zones.
Emergency Stop
If you have to turn off the mixer in a emergency you must: Electric: either
turn off at switch or at the mains, Petrol: turn the engine switch off, see
engine manual.
Fire Fighting
If your mixer catches fire, turn off the electric supply. Using a dry powder
or CO2 fire extinguisher put out the fire. If the fire can not be put out,
keep away and call the fire brigade. If you are in any doubt about the safety
condition of your machine, please contact your Belle authorized Service
Dealer.
Safety Instructions**
Warning Decals
| This Way Up
---|---
| Read Operators Manual
| Caution Taken When Handling
| Do Not Hang
| Only Stack 3 High.
Assembly Instructions
|
---|---
Mixing Hints
A few hints on mixing. First add water, about 1 /2 gallons approximately, depending on the type of mix. Cement should go in after some of the aggregates work consistently to the ratio of ingredients as listed below for whatever type of concrete mix you are working to. Beware of low grade aggregates, this only leads to trouble later on with sinking and frost spoiling the appearance of the pour. Also importantly do not get the concrete mix too wet as this can reduce the strength and is less able to withstand weathering. Never throw material into the mixer, trickle it steadily over the rim or it will stick mixing time for concrete is 1/2 minutes, this is taken when all the material, including the water has entered the drum. Over mixing can reduce strength and cause segregation of the coarser aggregates. Keep your mixer clean, the slightest trace of material left in the drum, will harden and attract more each time you use it until the machine is useless. Do not throw bricks into a mixer drum to clean it out. The best method is 1” gravel and clean water, use plenty of it, as this will do the job in half the time.
Service & Maintenance
Before starting any maintenance or repairs, switch off motor, and isolate from
the main power supply.
On completion of maintenance, check that the mixer functions correctly and
that all guards are correctly fitted.
ELECTRIC MIXER
All portable electric appliances are dangerous if abused. This machine will
only operate on one voltage. Check the power supply to ensure it corresponds
to the voltage as indicated on the rating label.
Make sure that the motor is switched off before you plug it into the power
supply.
230v – Always use a Residual Current Device (“RCD”), (earth leakage
trip), plugged directly into the 230v socket. If using an extension cable,
plug it directly into the RCD. 110v – When using a portable transformer it
must have a minimum output of 2.5kw and to continuous rated.
The symbols on the ON/OFF switch are 0 (Red)=OFF and I (Green)=ON in
accordance with international standards.
Ensure cable is fitted with cable clip to the mixer frame at all times.
EXTENSION CABLES
If you need to use an extensAon cable it must be no longer than 30 metres (100
feet) in length. The wire section must be 1.5mmh on 230v. Ensure that the
extension cable is carefully laid out avoiding liquids, sharp edges and places
where vehicles might run over it. Avoid allowing the extension cable to be
trapped underneath the mixer. Unroll it fully or it will overheat and could
catch fire. Make sure that any extension cable connections are dry and safe.
THERMAL PROTECTION DEVICE
The Electric motor is fitted with a Thermal Protection Device. Should
circumstances arise where this activates, the motor will stop. Once the
thermal trip resets itself the motor will be able to be restarted at the
on/off switch.
The thermal trip reset time could vary from 2 minutes to 10 minutes.
CLEANING
Wipe off any external material. DO NOT use petrol, turpentine, lacquer or
paint thinner, dry cleaning fluids or similar products. Never let any liquids
near the engine/motor. Use 1″ gravel and clean water to clean the inside of
the drum. DO NOT use bricks etc. as this will damage the drum.
Ensure the extension lead is always unplugged before the motor cover is
removed.
Any maintenance and repairs carried out, to any of the electric
components must be undertaken by a qualified electrician.
Technical Data
Mixer Model
Overall Dimensions
A – Height (Off Stand)
B – Width (Off Stand)
C – Length (Off Stand)
D – Height (On Stand)
E – Width (On Stand)
F – Length (On Stand)
Unladen Weight – Electric
Maximum Drum Capacity
Maximum Mixing Capacity
Drum speed (RPM)| Electric Equipment
Nominal Voltage
Nominal Current
Nominal Power
Current Frequency
Motor R.P .M.
Protective System
Power Consumption
Sound Power Level
---|---
BELLE LIGHT CONSTRUCTION EQUIPMENT
ALTRAD BELLE
Sheen, Nr. Buxton, Derbyshire, SK17 0EU, GB
Tel. +44 (0)1298 84606 – Fax +44 (0)1298 84722 – Email: sales@altrad-
belle.com
www.Altrad-Belle.com
ALTRAD (Group Holding)
125, Rue du Mas Carbonnier, 34000, Montpellier, France
Tel. +33 (0) 4 67 50 53 66 – Email:
admin@altrad.com
www.altrad.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>