ROPOX 40-14771 StandardLine Height Adjustable Washbasin Installation Guide

June 9, 2024
ROPOX

40-14771 StandardLine Height Adjustable Washbasin

Installation interfaces
ROPOX BATHROOM PRODUCTS
PDF 6131 / 08.03.2022

Contents
ROPOX SWING WASHBASIN …………………………………………………………………………………………………………. 2 ROPOX SUPPORT WASHBASIN …………………………………………………………………………………………………… 11 ROPOX SLIMLINE WASHBASIN……………………………………………………………………………………………………. 18 ROPOX STANDARDLINE WASHBASIN …………………………………………………………………………………………. 19 ROPOX ADAPTLINE WASHBASIN ………………………………………………………………………………………………… 20 ROPOX SHOWER SEAT ……………………………………………………………………………………………………………….. 21 ROPOX TOILET LIFTER ……………………………………………………………………………………………………………….. 24 CONNECTION ADAPTERS ­ SWING WASHBASIN ………………………………………………………………………… 28 CONNECTION ADAPTERS ­ OTHER WASHBASINS ……………………………………………………………………… 29

The dimension sketches are intended as guidelines only. For final dimension drawing, always refer to plan drawing
of the specific project.

Page 2

© ROPOX 2015

Ropox Swing Washbasin
Fixed, Short cover ­ plumbing visible
(40-41110)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable.
Load-tested according to DS/ISO 17966 the maximum user weight is 80kg (176 lbs).
Max. tensile load of upper screws 88kg/screw (194lbs/screw)
The washbasin is supplied with a set of 8 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.
PLUMBING The drain hose is a flexible Ø32 (1 ¼”) hose.
The water supply ends in 2 (two) 90° shut-off valves with ½” or 3/8″ outside thread pointing downward (not included). The flexible water connection hoses from the washbasin end in Ø10 pipes. Adapter fittings from these pipes to the shut-off valves are available with Ropox and as standard plumbing components. If a location of the drain higher than the recommended positioning is required, there may be a risk of reduced draining from the washbasin.
For purchase of adapters for connection to various standard installations, see “Connection Adapters ­ Swing Washbasin”.
NOTE: All dimensions are based on a washbasin height of 800mm (23 5/8″) above floor level. If a change of this height is required, the recommended dimensions must be changed accordingly.
Page 3

© ROPOX 2015

Ropox Swing Washbasin
Fixed, Long cover ­ plumbing hidden
(40-41120)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable.
Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 80kg (176 lbs).
Max. tensile load of upper screws 88kg/screw (194lbs/screw)
The washbasin is supplied with a set of 8 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

Page 4

© ROPOX 2015

PLUMBING The drain hose is a flexible Ø32 (1 ¼”) hose.
The water supply ends in 2 (two) 90° shut-off valves with ½” or 3/8″ outside thread pointing downward (not included). The flexible water connection hoses from the washbasin end in Ø10 pipes. Adapter fittings from these pipes to the shut-off valves are available with Ropox and as standard plumbing components.
If a location of the drain higher than the recommended positioning is required, there may be a risk of reduced draining from the washbasin.
For purchase of adapters for connection to various standard installations, see “Connection Adapters ­ Swing Washbasin”.
NOTE: All dimensions are based on a washbasin height of 800mm (23 5/8″) above floor level. If a change of this height is required, the recommended dimensions must be changed accordingly.

Page 5

© ROPOX 2015

Ropox Swing Washbasin
Manual, Short cover ­ plumbing visible
(40-41130)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable.
Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 80kg (176 lbs).
Max. tensile load of upper screws 88kg/screw (194lbs/screw)
The washbasin is supplied with a set of 10 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

Page 6

© ROPOX 2015

PLUMBING The drain hose is a flexible Ø32 (1 ¼”) hose.
The water supply ends in 2 (two) 90° shut-off valves with ½” or 3/8″ outside thread pointing downward (not included). The flexible water connection hoses from the washbasin end in Ø10 pipes. Adapter fittings from these pipes to the shut-off valves are available with Ropox and as standard plumbing components.
If a location of the drain higher than the recommended positioning is required, there may be a risk of reduced draining from the washbasin. For purchase of adapters for connection to various standard installations, see “Connection Adapters ­ Swing Washbasin”.
NOTE: All dimensions are based on adjustment of the washbasin from 750 – 900 mm (29 ½” ­ 35 ½”) above floor level. If a change of this adjustment range is required, the recommended dimensions must be changed accordingly.

Page 7

© ROPOX 2015

Ropox Swing Washbasin
Manual, Long cover ­ plumbing hidden
(40-41140)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable.
Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 80kg (176 lbs).
Max. tensile load of upper screws 88kg/screw (194lbs/screw)
The washbasin is supplied with a set of 12 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

PLUMBING The drain hose is a flexible Ø32 (1 ¼”) hose.

The water supply ends in 2 (two) 90° shut-off valves with ½” or 3/8″ outside thread pointing downward (not included). The flexible water connection hoses from the washbasin end in Ø10 pipes. Adapter fittings from these pipes to the shut-off valves are available with Ropox and as standard plumbing components. If a location of the drain higher than the recommended positioning is required, there may be a risk of reduced draining from the washbasin.

For purchase of adapters for connection to
various standard installations, see “Connection Adapters ­ Swing Washbasin”.

NOTE:

All dimensions are based on adjustment of the

washbasin from 750 – 900 mm (29 ½” ­ 35 ½”) above floor level. If a change of this height-

adjustment range is required, the recommended dimensions must be changed accordingly.

Page 8

© ROPOX 2015

186 7 1/3″ 1/4″
226 8 9/10″

Ropox Swing Washbasin
Complete, incl. height adjustment and Dock-in
(40-40071 and 40-40072)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable. Height adjustment unit is tested according to DS/ISO 17966:2016, the maximum user weight has been fixed at 245kg (539 lbs) when the wash basin is in the Dock-in and 80kg (176 lbs) when wash basin is out of the Dock-in.
Max. tensile load of upper screws 120kg/screw (264lbs/screw)
The washbasin is supplied with a set of 10 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.
PLUMBING The drain hose is a flexible Ø32 (1 ¼”) hose. The water supply ends in 2 (two) 90° shut-off valves with ½” or 3/8″ outside thread pointing downward (not included). The flexible water connection hoses from the washbasin end in Ø10 pipes. Adapter fittings from these pipes to the shut-off valves are available with Ropox and as standard plumbing components. If a location of the drain higher than the recommended positioning is required, there may be a risk of reduced draining from the washbasin.
For purchase of adapters for connection to various standard installations, see “Connection Adapters ­ Swing Washbasin”.

NOTE:All dimensions are based on adjustment of the washbasin from 750 – 950 mm (29 ½” ­ 37 2/5″) above floor level. If a change of this height-adjustment range is required, the recommended dimensions must be changed accordingly.

Page 9

© ROPOX 2015

Ropox Swing Washbasin

Optional: Dock-in
(40-40069)

NOTE: only applicable for the basins 40-41110, 40-41120, 40-41130 and 40-41140. The Dock-in is included in the height adjustable wash basins 40-40071 and 40-40072.

CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable.

Tested according to DS/ISO 17966:2016, the maximum user weight has been fixed at 245kg (539lbs) when the wash basin is in the Dock-in and 80kg (176 lbs) when wash basin is out of the Dock-in.

Max. tensile load of upper screws 136kg/screw (300 lbs)

The unit will be supplied with a set of 4 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

13 2/5″ 10 1/4″

15 2/3″

6 1/3″

16″ 4 3/4″

8″ 4″ ”
18 3/4″

40-41110 and 40-41120
NOTE: All dimensions are based on a fixed height of the wash basin of 800mm (31 1/2″) above floor level. If a change of these dimensions is required, the recommended dimensions must be changed accordingly. Ropox can supply a mounting plate at request.

32″

13 7/10″

40-41130 and 40-41140
8″

8 7/9″

4″

NOTE:

All dimensions are based on a height of

4 3/4″ 16″

6 1/3″

the wash basin of 750-900mm (29 1/2″ ­

291/2″ ­ 37 2/5″

35 ½”) above floor level.

If a change of these dimensions is

required, the recommended dimensions

must be changed accordingly.

19 3/5″

Ropox can supply a mounting plate at

18 3/4″

request.

Page 10

© ROPOX 2015

Ropox Support Washbasin
Fixed
(40-44010 and 40-44011)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable. Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 400kg (880 lbs).
Max. tensile load of upper screws 150kg/screw (330 lbs)
The washbasin is supplied with a set of 6 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.
PLUMBING The drain is Ø32 (1 ¼”) and ends in an Ø32×88.5° drain elbow. The maximum protrusion of drain connection and elbow from the wall is 90mm (3 ½”) to allow for the covers. The water supply ends in 2 (two) 90° shut-off valves with ½” outside thread pointing downward (not included). The maximum protrusion of the shut-off valves from the wall is 90mm (3 ½”) to allow for the covers. If a location of the water supply and drain different from the recommended positioning is required or if there is a floor drain, the Support Washbasin will have no covers. For purchase of adapters for connection to various standard installations, see “Connection Adapters ­ Other Washbasins”.
NOTE: All dimensions are based on a washbasin height of 710mm (28″) above floor level. If a change of this height is required, the recommended dimensions must be changed accordingly. The illustrations show the left-hand model 40-44010
Page 11

© ROPOX 2015

Ropox Support Washbasin
Basic
(40-44012 and 40-44013)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable. Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 400kg (880 lbs).
Max. tensile load of upper screws 85kg/screw (187 lbs)
The washbasin is supplied with a set of 6 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.
PLUMBING The drain is Ø32 (1 ¼”) and ends in an Ø32×88.5° drain elbow. The maximum protrusion of drain connection and elbow from the wall is 90mm (3 ½”) to allow for the covers. The water supply ends in 2 (two) 90° shut-off valves with ½” outside thread pointing downward (not included). The maximum protrusion of the shut-off valves from the wall is 90mm (3 ½”) to allow for the covers. It is important that all hoses for water connection and drain are flexible to allow the frame to move freely within the height adjustment range of 710-1010mm (28″ ­ 39 8/10″) (including washbasin).
If a location of water supply and drain different from the recommended positioning is required or if there is a floor drain, the Support Washbasin will have no covers. For purchase of adapters for connection to various standard installations, see “Connection Adapters ­ Other Washbasins”.
NOTE: The illustrations show the left-hand model 40-44012
Page 12

© ROPOX 2015

Ropox Support Washbasin
Manual
(40-44014 and 40-44015)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable. Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 400kg (880 lbs).
Max tensile load of upper screws 71kg/screw (157 lbs)
The washbasin is supplied with a set of 8 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.
PLUMBING The drain is Ø32 (1 ¼”) and ends in an Ø32×88.5° drain elbow. The maximum protrusion of drain connection of elbow from the wall is 90mm (3 ½”) to allow for the covers. The water supply ends in 2 (two) 90° shut-off valves pointing downward (not included). The maximum protrusion of the shut-off valves from the wall is 90mm (3 ½”) to allow for the covers
It is important that all hoses for water connection and drain are flexible to allow the frame to move freely within the height adjustment range of 710-1010mm (28″ ­ 39 8/10″) (including washbasin). If a location of water supply and drain different from the recommended positioning is required and if there is a floor drain, the Support Washbasin will have no covers.
For purchase of adapters for connection to various standard installations, see “Connection Adapters ­ Other Washbasins”.
NOTE: The illustrations show the left-hand model 40-44014
Page 13

© ROPOX 2015

Ropox Support Washbasin
Electric left
(40-44016)

CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable. Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 520kg (1144 lbs).

Max. tensile load of upper screws 71kg/screw (157lbs).
The washbasin is supplied with a set of 8 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

PLUMBING The drain is Ø32 (1 ¼”) and ends in an Ø32×88.5° drain elbow. The maximum protrusion of drain connection and elbow from the wall is 90mm (3 ½”) to allow for the covers. The water supply ends in 2 (two) 90° shut-off valves with ½” outside thread pointing downward (not included).The maximum protrusion of the shut-off valves from the wall is 90mm (3 ½”) to allow for the covers.
Location and optimum orientation as shown in blue for water supply and in green for drain. It is important that all hoses for water connection and drain are flexible to allow the frame to move freely within the heightadjustment range of 710-960mm (28″ ­ 37 4/5″) (including washbasin). If a location of water supply and drain different from the recommended positioning is required or if there is a floor drain, the Support Washbasin has no covers.

For purchase of adapters for connection to various standard installations, see “Connection Adapters ­ Other Washbasins”. POWER Recommended location of socket in wall for optimum and hidden wiring is shown in red. If a different location is required, the cable from the control unit is 3200mm (126″).

Page 14

© ROPOX 2015

Ropox Support Washbasin
Electric right
(40-44017)

CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable. Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 520kg (1144 lbs).

Max. tensile load of upper screws 71kg/screw (157 lbs)
The washbasin is supplied with a set of 8 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.
PLUMBING The drain is Ø32 (1 ¼”) and ends in an Ø32×88.5° drain elbow. The maximum protrusion of drain connection and elbow from the wall is 90mm (3 ½”) to allow for the covers. The water supply ends in 2 (two) 90° shut-off valves with ½” outside thread pointing upward (not included). The maximum protrusion of the shut-off valves from the wall is 90mm (3 ½”) to allow for the covers.

Location and optimum orientation as shown in blue for water connection and green for drain. It is important that all hoses for water connection and drain are flexible to allow the frame to move freely within the heightadjustment range of 710-960mm (28″ ­ 37 4/5″) (including washbasin). If a location of water supply and drain different from the recommended positioning is required and if there is a floor drain, the Support Washbasin has no covers.

For purchase of adapters for connection to
various standard installations, see “Connection Adapters ­ Other Washbasins”.

POWER Recommended location of socket in wall for optimum and hidden wiring is shown in red. If a different location is required, the cable from the control unit is 3200mm (126″).

Page 15

© ROPOX 2015

27 5/9″

Ropox Support Washbasin
Optional: Sideways slide for Ropox Support Washbasin
(40-44030)
42 3/4″
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable. Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 400kg (880 lbs).
Max. tensile load of upper screws 41kg/screw (90 lbs)
PLUMBING The drain has a diameter of Ø32 (1 ¼”) and is provided with an Ø32×88.5° elbow. Max. protrusion of drain connection and elbow from the wall is 140mm (5 ½”) owing to the covers. The water supply ends in 2 (two) 90° shut-off valves with ½” outside thread. Location and optimum orientation as illustrated. Max. protrusion of shut-off valves from the wall is 140mm (5 ½”) owing to the covers. It is recommended to install water and drain connections as illustrated. All hoses for water and drain connections must be flexible for the unit to move freely within the range of adjustment.
1″

28″ ­ 39 8/10″ 28″ ­ 37 4/5″

50 mm 2″

4″

Max. 140 mm

2″

5 ½”

18 3/4″

2 ¾”

20 9/13″
Manual/electrical height adjustment, plumbing located behind the cover.

Page 16

9 4/9″

© ROPOX 2015

27 61/64″ ­ 39 8/10″ 27 61/64″ ­ 37 4/5″

8 2/3″

Max. 140 mm 5 ½”

50 mm 2″

1″ 45 1/21″ 20 9/13″

5 8/9″ 3″

2 ¾”

Manual/Electrical height adjustment, plumbing visible beside the washbasin. (plumbing may be located on either side of the washbasin).
POWER Recommended location of socket in wall for optimum and hidden wiring. In case of an alternative solution, the cable from the control unit is 3200mm (126″).

Page 17

© ROPOX 2015

Ropox SlimLine Washbasin
Electric
(40-15601)

CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall.

700mm / 27 ½”

/ 44 1/5″ 7 7/8″

Tested in accordance with DS/EN 12182:2012 and DS/ISO 17966:2016 with the following max. user weights: 40-15601: 165kg (363 lbs)

27 ¾”

Max. tensile load of upper screws 68kg/screw (150 lbs)

The washbasin is supplied with a set of screws and

13 ¾”

rawlplugs suitable for mounting on a concrete wall. The fitter

should always consider the material, condition and strength

of the wall and use screws and rawlplugs suitable for the

specific wall type.

PLUMBING
The drain is Ø32 (1 ¼”) and ends in an Ø32×88.5° drain elbow.
The water supply ends in 2 (two) 90° shut-off valves with
½” outside thread pointing downwards in an angle of 45° (not included). The maximum protrusion of the shut-off
valves and drain connection should be max 77mm (3″) to allow for the covers.

/ 80 3/5″

The optimum location and orientation is as shown.
It is important that all hoses for water connection and drain are flexible to allow the frame to move freely within the height-adjustment range of 700-1000mm (27 1/2″ ­ 39 2/5″) (including washbasin). If a different location of water supply from the recommended positioning is
required and if there is a floor drain, the installation cover (40-15610) can’t be used.

/ 39 3/8″

POWER Recommended location of socket in wall for optimum and hidden wiring is above unit as shown. The cable from the control unit is 2000mm (78″).

18 3/5″

Page 18

13 1/5″

/1 1/20″ 5 4/5″ 4 4/5″
© ROPOX 2015

Ropox StandardLine Washbasin
Electric
(40-14770, 40-14772 og 40-14773)

CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall.

9 1/16″

6 1/16″ 6 1/16″

9 1/16″

Tested in accordance DS/ISO 17966:2016 with the following max. user weights: 40-14772: 200kg (440 lbs) 40-14773: 200kg (440 lbs) 40-14770: 200kg (440 lbs) (when using a porcelain wash basin)

/ 22″

Max. tensile load of upper screws 50kg/screw (110 lbs)

The washbasin is supplied with a set of screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

PLUMBING The drain is Ø32 (1 ¼”) and ends in an Ø32×88.5° drain elbow. The water supply ends in 2 (two) 90°
shut-off valves with ½” outside thread pointing upwards (not included). The maximum protrusion of the shut-off
valves and drain connection should be max 90mm (3 ½”) to allow for the covers.

12 8/9″

12 8/9″

9 1/5″

9 1/5″ 3 10/11″
1 15/16″

2 3/4″

/ 18 4/5″
/ 9 ½”
5 1/4″

The optimum location and orientation is as shown in green. It is important that all hoses for water connection and drain are flexible to allow the frame to move freely within the height-adjustment range of 7001000mm (27 1/2″ ­ 39 2/5″) (including washbasin).

4 ¾””

4 4/5″

3 1/5″

3 1/3″ 5 2/3″

For purchase of adapters for connection to various standard installations, see “Connection Adapters ­ Other Washbasins”.

POWER Recommended location of socket in wall for optimum and hidden wiring is shown in red. If a different location is required, the cable from the control unit is 3200mm (126″).

2 3/5″ 5 4/5″
8 3/5″ 11 4/5″ 15″

Page 19

© ROPOX 2015

39 3/8″ 35 2/3″ 24 1/20″ 27 ½” ­ 35 3/7″

Ropox AdaptLine Washbasin

Manual
(40-42110, 40-42011 og 40-42012)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall.

11 4/5″ 2 3/4″

Tested in accordance with DS/ISO 17966:2016 with the following max. user weights: 40-42011: 165kg (363 lbs) 40-42012: 120kg (264 lbs) 40-42110: 200kg (264 lbs) (when using a porcelain wash basin)

Max. tensile load of upper screws 62kg/screw (137 lbs)

The washbasin is supplied with a set of screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

PLUMBING
The drain is Ø32 (1 ¼”) and ends in an Ø32×88.5° drain elbow.
The water supply ends in 2 (two) 90° shut-off valves with ½” outside thread pointing downwards (not included).

The optimum location and orientation is as shown. It is important that all hoses for water connection and drain are flexible to allow the frame to move freely within the height-adjustment range of 700900mm (27 1/2″ ­ 35 2/5″) (including washbasin).

7 1/10″

For purchase of adapters for connection to
various standard installations, see “Connection Adapters ­ Other Washbasins”.

3 5/9″

19 2/3″ 9 5/6″

Page 20

© ROPOX 2015

Ropox Shower Seat
Seat, with and without legs
(40-43011 and 40-43016)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 150kg (331lbs) for the seat without legs and 200kg (441lbs) for the seat with legs. The hatched area is the minimum area for reinforcement of the wall.
Max. tensile load of upper screws 40-43011: 70kg/screw (154lbs) 40-43016: 225kg/screw (496lbs)
NOTE: All dimensions are based on a fixed seat height of 450mm (17 7/10″) above floor level. If a change of this height is required, the recommended dimensions must be changed accordingly. Seat with legs must be mounted with a seat height between 450 and 575mm (17 7/10″ and 22 3/5″) above floor level.
The seat is supplied with a set of 4 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

Page 21

© ROPOX 2015

Backrest, with and without arm supports
(40-43025 and 40-43030)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. According to DS/ISO 17966 the maximum user weight has been fixed at 50kg (110lbs) for each arm support. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable.
Max. tensile load of upper screws 40-43025: 110 kg/screw (243lbs)
NOTE: All dimensions are based on a fixed seat height of 450mm (17 7/10″) above floor level and a height of arm supports of 270mm (10 5/8″) above the seat height. If a change of these dimensions is required, the recommended dimensions must be changed accordingly. The backrest is supplied with a set of 4 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

Page 22

© ROPOX 2015

Ropox Shower Seat
Height adjustment of seat and backrest (40-43043)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. Load-tested according to DS/ISO 17966 the maximum user weight has been fixed at 150kg (330 lbs) for the seat and 50kg (110 lbs) for each arm support. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable.
Max. tensile load of upper screws 45 kg/screw (99 lbs)
NOTE: All dimensions are based on a seat without leg with height adjustable between 400 – 525mm (12 ¾” ­ 20 2/3″) above floor level. If a change of these dimensions is required, the recommended dimensions must be changed accordingly. The unit is supplied with a set of 8 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

Page 23

© ROPOX 2015

Ropox Toilet Lifter
Electric
(40-45026)
CONSTRUCTION The wall must be of proper screw material approved for wet rooms.

4 ”

Load tested in accordance with DS/ISO 17966, the max. user weight is 400kg.

Max. tensile load of top screws 40-45026: 44 kg/screw (97 lbs)

NOTE: The toilet lifter is supplied with a set of 6 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition, and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

PLUMBING The floor drain must be an outside Ø110mm (4 1/3in) drain pipe without a coupler and recommended completed at floor level. Optimal placement is shown in
shaded area. The water supply ends with one 90° shutoff valve with ½in outside thread pointing upward. The recommended location of water is
illustrated with the shaded area.
POWER The optimum location is illustrated with the socket symbol. An alternative location of the power point in the wall must be
within the shaded area. If a location outside the unit is wanted, the cable from the control is 3200 mm (126″). For another location, it must always be controlled that the power cable is fixed in a way that is does not prevent the height adjustment.

4 3/4″

15 3/4″

20 5/8″

2 3/5″ 4″

Water connection area Electric connection area

4 21/64″

3 21/32″

Page 24

Floor drain must sit flush with floor © ROPOX 2015

Ropox Toilet Lifter

Manual
(40-45027)

Installation information

CONSTRUCTION The wall must be of proper screw material approved for wet rooms.

Load tested in accordance with DS/ISO 17966, the max. user weight is 400kg (880 lbs). The grey-shaded area states the minimum area for strengthening in the wall.

Max. tensile load of top screws 40-45027: 44 kg/screw (97 lbs)
NOTE: The toilet lifter is supplied with a set of 6 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition, and strength of the wall and use screws and rawlplugs suitable for the specific wall type.
PLUMBING The floor drain must be an outside Ø110mm (4 1/3in) drain pipe without a coupler and recommended completed at floor level. Optimal placement is shown
in shaded area. The water supply ends with one 90° shut-off valve with ½in outside thread pointing upward. The recommended location of water
is illustrated with the shaded area.

4 3/4″

15 3/4″

20 5/8″

2 3/5″ 4″

Vand Water connection area
Electric connection area

4 21/64″

3 21/32″

Page 25

GFulolovr adrfalinømbusstksait flluashfswliuthtftloeors plant

med gulv

© ROPOX 2015

Ropox Toilet Support Arms
All models of Straight and Wave
(40-40110, 40-40115, ..20, ..25, ..40, ..45, ..50 og ..51)
CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable.
The Toilet Support arms from 40-40110 up to 40-40145 are all 900mm (35 ½”) long. The models 40-40150 and 40-40151 are 760mm (30″).
All support arms are load-tested according to DS/ISO 17966 the max user weight are:
Max. user weight according to DS/EN 12182 40-40110: 190 kg (418 lbs) 40-40115: 190 kg (418 lbs) 40-40120: 390 kg (858 lbs) 40-40125: 390 kg (858 lbs) 40-40140: 385 kg (847 lbs) 40-40145: 385 kg (847 lbs) 40-40150: 255 kg (561 lbs) 40-40151: 255 kg (561 lbs) 40-40152: 385 kg (847 lbs)
Max. tensile load of upper screws 40-40110: 80 kg/screw (176 lbs) 40-40115: 80 kg/screw (176 lbs) 40-40120: 90 kg/screw (198 lbs) 40-40125: 90 kg/screw (198 lbs) 40-40140: 160 kg/screw (352 lbs) 40-40145: 160 kg/screw (352 lbs) 40-40150: 90 kg/screw (198 lbs) 40-40151: 90 kg/screw (198 lbs)
NOTE: All dimensions are based on a fixed height of the toilet support of 800mm (31 ½”) above floor level. If a change of this height is required, the recommended dimensions must be changed accordingly.
The unit is supplied with a set of 6 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

Straight
40-40110 40-40120 40-40140 40-40150 40-40152

Wave
40-40115 40-40125 40-40145 40-40151

Page 26

© ROPOX 2015

Ropox Toilet Support Arms

Optional: Height-adjustable wall fitting
(40-40907)

CONSTRUCTION The wall must be made of a material suited for screw mounting and approved for damp rooms. The hatched area is the minimum area for reinforcement of the wall. Reinforcement from floor to ceiling is advisable.
All support arms are load-tested according to DS/ISO 17966 the max user weight are:
Max. user weight according to DS/ISO 17966 40-40110: 190 kg (418 lbs) 40-40115: 190 kg (418 lbs) 40-40120: 325 kg (715 lbs) 40-40125: 325 kg (715 lbs) 40-40140: 325 kg (715 lbs) 40-40145: 325 kg (715 lbs) 40-40150: 255 kg (561 lbs) 40-40151: 255 kg (561 lbs)

Max tensile load of upper screws 40-40110: 80 kg/screw (176 bs) 40-40115: 80 kg/screw (176 lbs) 40-40120: 90 kg/screw (198 lbs) 40-40125: 90 kg/screw (198 lbs) 40-40140: 160 kg/screw (352 lbs) 40-40145: 160 kg/screw (352 lbs) 40-40150: 90 kg/screw (198 lbs) 40-40151: 90 kg/screw (198 lbs)

Wave
40-40115 40-40125 40-40145 40-40151

Straight
40-40110 40-40120 40-40140 40-40150 40-40152

NOTE:
All dimensions are based on a fixed height of the toilet support of 800mm +/- 60mm (31 ½” +/- 2 1/3″) above floor level. If a change of this height is required, the recommended dimensions must be changed accordingly.

The unit is supplied with a set of 8 screws and rawlplugs suitable for mounting on a concrete wall. The fitter should always consider the material, condition and strength of the wall and use screws and rawlplugs suitable for the specific wall type.

Distance A
Acc. to standard DS 3028
DIN 18040-1

A 600 mm (23 5/8″) 712-762 mm (28 1/32″-30″)
Page 27

© ROPOX 2015

Connection Adapters ­ Swing Washbasin
The components illustrated below are available as optional extras depending on the type of installation in the building.

Water supply adapters
Swing Wash Basin

Hose from basin

Adapters

Installation in room (not included)

Water hose extensions
Hoses from basin
10mm
Drain adapters
Swing washbasin

10mm

10mm -> 1/2″ Item No. 97001667
10mm -> 3/8″ Item No. 97001668

1/2″ thread
3/8″ thread

Coupling piece

10mm -> 15mm Item No. 97001665

15mm pipe

Extra hose

1/2″ x 1/2″, 0,5m (19,7″), steel Item No. 97001123

10mm -> 1/2″ Item No. 97001101
Drain from washbasin

1/2″ x 1/2″, 1m (39,4″), plastic Item No. 97001120

Adapters No adapter required

Installation in room (not provided)
ø32 (1 ¼”)

Drain extensions
Drain hose from washbasin
Ø32 (1 ¼”)

Ø32 (1 ¼”)

Ø32 -> Ø40 Item No. 97001660

Ø40 (1 ½”)

Coupling piece

Ø32 -> Ø50 Item No. 97001661

Ø50 (2″)

Extra drain hose

Ø32 Flex hose, 27-62cm (10,6″-24,4″) Item No. 97001162

Ø32-Ø32 Item No. 97001062
Page 28

Ø32 Flex hose, 40-110cm (15,7″-43,3″) Item No. 97001161
© ROPOX 2015

Connection Adapters ­ Other Washbasins
The components illustrated below are available as optional extras depending on the type of installation in the building.

Water supply adapters
Hoses from wash basin

Adapters

Installation in room (not included)

No adapter required

1/2″ thread

1/2″

1/2″ -> 3/8″ Item No. 97001670

3/8″ thread

Water hose extensions
Hose from washbasin

Coupling piece

1/2″ -> 15mm Item No. 97001666

15mm pipe

Extra hose

1/2″ x 1/2″, 0,5m (19,7″), steel

1/2″

Item No. 97001123

Drain adapters

1/2″ -> 1/2″ Item No. 97001669
Drain from wash basin

1/2″ x 1/2″, 1m (39,4″), plastic Item No. 97001120

Adapter No adapter required

Installation in room (not provided)
Ø32 (1 ¼”)

Ø32 (1 ¼”)

Drain extensions
Drain hose from wash basin

Coupling piece

Ø32 -> Ø40 Item No. 97001660

Ø40 (1 ½”)

Ø32 -> Ø50 Item No. 97001661

Ø50 (2″)

Extra drain hose

Ø32 (1 ¼”)

Ø32-Ø32 Item No. 97001062
Page 29

Ø32 Flex hose, 27-62cm (10,6″-24,4″) Item No. 97001162
Ø32 Flex hose, 40-110cm (15,7″-43,3″) Item No. 97001161 © ROPOX 2015

Page 30

© ROPOX 2015

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals