MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger Owner’s Manual

June 9, 2024
MEAN WELL

360W Programmable Desktop Type Battery Charger

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery
Charger

ENC – 360 series

ENC-360 Series 360W Programmable Desktop Type Battery Charger

|
---|---
https://www.meanwell.com/webapp/product/search.aspx?prod=ENC-360&pdf=RU5DLUUucGRm&a=4| https://www.youtube.com/watch?v=JIPKy0rufsQ&list=PLvUyt_OJELVrHoIIRgvHF2NQ-j39-NH-J&index=17

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger -
fig 1

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger -
sambol 1

Features

  • Charger for lead-acid batteries (flooded, Gel and AGM) and li-ion batteries (lithium iron and lithium manganese)
  • Built-in 3 stage programmable charging curve
  • Universal AC input / Full range
  • Built-in active PFC function
  • Fanless design, cooling by free air convection
  • Built-in temperature compensation function
  • Protection: Short circuit / Over voltage /Over temperature / Battery under voltage / Battery over voltage / Battery reverse polarity protection
  • 3 years warranty

Applications

  • Radio system backup solution
  • Electric scooter charger
  • Surveillance system

■ GTIN CODE
MW Search https://www.meanwell.comiserviceGTIN.aspx

Description

ENC-360 is a single output 360W AC/DC desktop type charger with 3 stage charging curve. In addition to the embedded pre-defined charging curves, the default curve is programmable and thus able to accommodate different types of batteries, such as lead-acid batteries (gel, flooded and AGM) and li-ion batteries (lithium iron and lithium manganese). With the rugged mechanical design along with the high efficiency circuitry, ENC-360 operates for the ambient temperature range -30–F70°C under free air convection.

■ Model Encoding

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger -
fig 2

SPECIFICATION

MODEL ENC-360-12 ENC-380-24 ENC-360-48
OUTPUT BOOM CHAFtGEVIXTAGE(Wlea)0661411 14AV 28.8V
FLOAT GORGE VOLTAGEiroltKOINIP I 3.I3V 27.6V 552V
CHARGE VOLTAGE RANGE NS3 9 – 15V 18 – 30V 38 – 80V
OUTPUT CURRENT(CC) (default) 24A 12A 6A
RATED POWER 345.6W 345.6W 345.6W
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Nola 85 – 250AH 45 – 125AH 25 –

t35AH
LEAKAGE CURRENT FROM BATTERY (Typ.)| <1mA
INPUT| VOLTAGE RANGE Nowa| 90- 264VAC 127 – 370VDC
FREQUENCY RANGE| 47 -83Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC. PF>0.95/230VAC at full load
EFFICIENCY (Typ.)| 91% 193% [ 94%
AC CURRENT (Typ.)| 3.8A/115VAC 1.9Al230VAC
INRUSH CURRENT (Typ.)| COLD START 80A at 230VAC
LEAKAGE CURRENT| <3.5mA I 240VAC
PROTECTION| SHORT CIRCUIT Nate| Protection type : Shut down 0/P voltage, re- power on to recover
OVER VOLTAGE Note.?| 15.5 – 18.2V 131 -38.5V 162.1 -72.9V
Protection type : Shut down and latch off de voltage. re-power on to recover
REVERSE POLARITY| By intemal fuse
OVER TEMPERATURE| Shutdown 0/P voltage. recovers automatically after temperature goes down
FUNCTION| TEMPERATURECOMPFJ15A11011| By NTC
EIMROMENT| WORKING TEMP.| -30- +70.0 (Refer to ‘Derating Curve’)
WORKING HUMIDITY| 20 – 95% RH non-condensing
STORAGE TEMP.. HUMIDITY| -40- .1.81C. 10 – 95%RM non-condensing
TEMP. COEFFICIENT| ± o.ostic (0- sot )
VIBRATION| 10- 500Hz. 2G 10minilcycle.80min. each along X. Y. Z axes
SAFETY &
EMC (Note a)| SAFETY STANDARDS| IEC82388-1. UL823138-1. EACTP TC 004. IISMICNS14338-1, J82388-1(2020)(Only for 12V) approved: Meet BS EN/ENI32388-1
WITHSTAND VOLTAGE| 1112-0/P:3KVAC IIP-FG:2KVAC 0/P-FG:0.5KVAC
ISOLATION RESISTANCE| UP-0/P. UP-Fa 0/P-FG:100M Ohms / 500VDC / 25’C/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| ISENE1455CO2(05aR32)/FCCRIRT15(C6FR.12)| Class B
Radiated| BSENEM32 (CSPR32) I FCCPARTIKSPRZ2)| Class El
Harmonic Current| BS ENIEN81000-3-2| –
Vohage Picker| BS EN/EN61000-3-3| –
EMC IMMUNITY| BS ENJEN55035. BSMI CN513438: J5503 (H29) (Only for 12V)
Parameter| Standard| Test Level / Note
ESD| EIS ENIEN81000-4-2| Level 3. 8KV air : Level 2. MN contact
Radiated| BS EN/EN81000-4-3| Level 2. 3V/m
EFT/Bust| BS EN/041310034-4| Level 2. 1KV
Surge| BS EN/EN81000-4-5| Level 2. IKVILine-Linelevel 3. 2NY/tine-Earth
Conducted| BS ENIEN01000-443| Level 2. 3Vrms
Magnetic Field| BS EN/EN61000-4-8| Level I. lAlm
Voltage Dips and IMenupticos| BS ENIEN81000-4-11| >95% dip 0.5 periods. 30% dip 25 periods. >95% itterruptions 250 periods
OTHERS| MTBF| 1178.7K hrs min. Tekordia SR-332 (Bellcore) : 138.7K hrs min. MIL-HDBK-21 F (25C)
DIMENSION| 192’178’45.5mm (L’W’H)
PACKING| 1.5Kg: 10pcs/18Kg /1.38CUFT

NOTE

  1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
  2. All parameters NOT specially mentioned are measured at 230VAC input. rated load and 25 (‘ of ambient temperature.
  3. This is the range when programming Vboost or Vfloat by using SBP-001. the smart battery charging programmer.
  4. This is MEAN WELL’s suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
  5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. This protection mechanism is specified for the case the short circuit occurs after the charger is tumed on.
  7. Each model incorporates a MCU-controlled dynamic over voltage protection. which is about 115% of Vboost over Constant Current stage and Constant Voltage stage whereas 115% of Vf bat over Float stage.
  8. The battery charger is considered as an independent unit. but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests. please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  9. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5 (71000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability Disclaimer : For detailed information. please refer to https://www.meanwell.com/serviceDisclaimetaspx

Block Diagram

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger -
fig 3

Derating Curve

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger -
fig 4

Static Characteristics

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger -
fig 5

Function Manual

1.Charging Curve
※ This series provides a 3 stage charging. The default curve is programmable, whereas other pre-defined curves can be activated by the means of the DIP switch; please refer to the table below and the Mechanical Specification.
※ To accommodate the parameters of the charging curve, SBP-001, the smart battery charging programmer designed by MEAN WELL, and a personal computer are needed. Please contact MEAN WELL for details.
◎ Default 3 stage charging curve

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger -
fig 6

◎ Suitable for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese).
◎ Embedded 3 stage charging curve

MODEL Description CC(default) Vboost Vfloat
12V Default, programmable 24A 14. 14.
Pre-defined, gel batter 14 14.
Pre-defined, flooded battery 14. 13.
Pre-defined, AGM battery 15. 14.
24V Default, programmable 12A 29. 28.
Pre-defined, gel battery 28 27.
Pre-defined, flooded battery 28. 27.
Pre-defined, AGM battery 29 27
48V Default, programmable 6A 58. 55.
Pre-defined, gel battery 56 54.
Pre-defined, flooded battery 57. 54.
Pre-defined, AGM battery 58 54

2. Front Panel LED Indicators & Corresponding Signal at Function Pins

LED Description
Green Float (stage 3)
Orange Charging (stage 1 or stage 2)

Mechanical Specification

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger -
fig 7

Terminal Pin No. Assignment (TB1):

Pin No. Assignment
1,2 +V
3,4 -V

Note: Please use wires with a cross section of 0.5 – 4.0 mm2 (12~20AWG) for connection.
Recommended wires strip length is 9 mm and screw torque is 4.0 lb-inch (0.4~0.5Nm).

DIP SW:

1 2 Description
OFF OFF Default, programmable
ON OFF Pre-defined, Gel battery
OFF ON Pre-defined, flooded battery
 ON ON Pre-defined, AGM battery

Connector Pin No. Assignment (CN31) :
HRS DF11-6DP-2DS or equivalent

Pin No. Assignment Mating Housing Terminal
1 Prog- +3.3V HRS DF11-6DS
or equivalent HRS DF11-**SC

or equivalent
2| Prog- GND
3| Prog- RX
4| Prog- TX
5| RTH+
6| RTH-

Accessory List

Item Quantity
1 NTC sensor wire
2 NTC mating wire

MEAN WELL ENC-360 Series 360W Programmable Desktop Type Battery Charger -
fig 8

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals