LNC A04967B6 Hemera 6-Light Matte Black Tiffiany Modern-Contemporary Linear LED Large Indoor Kitchen Island Pendant Light Installation Guide

June 9, 2024
LNC

LNC A04967B6 Hemera 6-Light Matte Black Tiffiany Modern-Contemporary Linear LED Large Indoor Kitchen Island Pendant Light

LNC A04967B6 Hemera 6-Light Matte Black Tiffiany Modern-Contemporary
Linear LED Large Indoor Kitchen Island Pendant Light  

INTRODUCTION

Item Number: A04967B6

WARNING (To reduce the risk of fire, electric shock, or personal injury):

  1. We suggest installation by a licensed electrician.

  2. Please read the instruction carefully and save it as you may need it at a later time.

  3. Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
    » Go to the main fuse, or circuit breaker, box in your home.
    Place the main power switch in the “OFF” position.
    » Place the wall switch in the “OFF” position.

  4. Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.

  5. Make sure that the ceiling or wall can stand the weight of the lamp before installation.

  6. Make sure the voltage you are using is 120V. The maximum wattage is Type B , Max 40W per bulb.

  7. Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.

  8. When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.

  9. The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.

IMAGE FOR FINISHED PRODUCT

LNC A04967B6 Hemera 6-Light Matte Black Tiffiany Modern-Contemporary Linear
LED Large Indoor Kitchen Island Pendant Light

TOOLS REQUIRED (NOT INCLUDED)

Before starting assembly and installation please prepare the needed tools as below picture

Tools Required

PARTS TYPE & QTY INCLUDING

(C) Single bar (1)
(D) Green ground screw (1)
(E) Canopy (1)
(F) Loop (4)
(G) Hex nut (1)
(H) Cap nut (1)
(I) Quick link (2)
(J) Tube
(K) Fixture body (1)
(L) Glass strip-A (19)
(M) Glass strip-B (19)
(N) Glass strip-C (19)

ACCESSORIES & QTY ENCLOSED

(A) Wire connector (3)
(B) Mounting screw (2)

OUTLET BOX
Parts Type & Qty Including

ASSEMBLY & INSTALLATION INSTRUCTIONS

  1. Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.

  2. Make pre-installation
    Assembly & Installation Instructions
    Step A1 »** Carefully pass the fixture wires through one side of tube (J), then screw tube (J) onto fixture body (K) as shown in the picture above. 4. Make installation.
    Step A2 »** Open quick links (I). Attach quick links (I) to loops (F) on canopy (E) and tubes (J). Close quick links (G).

  3. Turn off power
    Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.
    » Go to the main fuse, or circuit breaker, box in your home.
    Place the main power switch in the “OFF” position.
    » Place the wall switch in the “OFF” position.

  4. Make installation
    Assembly & Installation Instructions Step B1 »
    Unscrew hex nut (G) and cap nut (H) from single bar (C).
    Step B2 » Attach single bar (C) to the outlet box with mounting screws (B).
    Note: the side of single bar (C) marked “GND” must face out.
    Step B3 » If needed, shorten the length of fixture wires. At this point, the remaining wire length measured above single bar (C) is at least 6″.
    Step B4 » Make wire connections Connect wires as below wires connection shown. PLEASE NOTE THAT GROUND WIRE IS BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
    Connect ground wires according to the below chart
    Connect ground wires according to the below chart
    Connect wires according to the below chart
    ***Connect Black or Red Supply Wire to| Connect White Supply Wire to
    ---|---
    Black| White
    Parallel cord (round & smooth)| *Parallel cord (square & ridged)
    Clear, Brown, Gold or Black without tracer| Clear, Brown, Gold or Black with tracer
    Insulated wire(other than green) with copper conductor| Insulated wire(other than green) with silver conductor

  • Note: When parallel wires (SPT I& SPT ll) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or  smooth (see illus.)| Neutral Wire

Twist wires together with plastic wire connectors until tightly joined, and wrap each connector with approved electrical tape. Be sure that no wire strands are exposed and then carefully tuck all wires into the outlet box.
Step B5 »
Raise canopy (E) to the ceiling and secure canopy (E) in place by tightening hex nut (G) and cap nut (H) onto the pre-assembled threaded nipple on single bar (C).

NOTE: The canopy (E) should be snug against the ceiling and cap nut (H).
If not, adjust the threaded length of the pre-assembled threaded nipple on single bar (C):

  *  **Unscrew the pre-assembled hex nut.  

**

  *  **Screw the pre-assembled threaded nipple in or out of single bar (C).  

**

  *  **When the secure length is achieved, tighten the pre-assembled hex nut and back to step B5.**  

Step B6 » 1) Install bulbs (not included) (Please do not exceed the maximum wattage recommended on the socket.)
2) Hang all the glass strips on fixture body (K).

  1. Check everything is already installed properly, then you could turn on the light. Enjoy!

ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustration when ordering parts.

CLEANING
To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner (such as mild and non-abrasive soap). Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.

Customer Support

+1 850 296 2377 Working hours : Mon – Fri 9:00 – 16:00 EST
homecustomercare@outlook.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

LNC User Manuals

Related Manuals