TECHNICAL DATA

Order no.

|

5323040

---|---
Product type| |

P2001 M

Measuring range|

mm

|

± 0.5

Measuring range|

inch

|

± .020”

Measuring force|

N

|

0.75 N +/-0.15 N

Increase in measuring force|

N/mm

|

0.1 N/mm

Sensitivity deviation|

%

|

0.3

Repeatability fw|

µm

|

0.15

Repeatability fw|

inch

|

6 µ”

Hysteresis fu|

µm

|

0.2

Hysteresis fu|

inch

|

8 µ”

Linearity deviation within +/-0.1 mm|

µm

|

0.6

Linearity deviation within +/-.0039”|

inch

|

24 µ”

Linearity deviation within +/-0.5 mm|

µm

|

1.5

Linearity deviation within +/-.020”|

inch

|

60 µ”

IP protection category:| |

IP 40

Cable length|

m

|

2.5

Temperature coefficient|

µm/°C

|

0.15

Compatibility| |

Mahr VLDT

ACCESSORIES

Order no.| Product description| Product name| Compatibility| Product type
---|---|---|---|---
| | | |
5323130| Extension cable 2.5 m| Extension cable 2.5 m (Mahr VLDT)| Mahr VLDT| C2025 M
5323140| Extension cable 5 m| Extension cable 5 m (Mahr VLDT)| Mahr VLDT| C2050 M
5323150| Extension cable 7.5 m| Extension cable 7.5 m (Mahr VLDT)| Mahr VLDT| C2075 M
5323160| Extension cable 10 m| Extension cable 10 m (Mahr VLDT)| Mahr VLDT| C2100 M

Millimar P2004 M / P2004 T / P2004 U / P2004 F

Inductive Probe


FFEATURES

  • Models with or without compressed-air (pneumatic) lifter or vacuum retraction
  • Measuring pin mounted in ball bearing guide
  • High linearity over the entire measuring range
  • Excellent electromagnetic shielding (EMC)
  • All probes can be easily converted from axial to radial by mounting a slip-on cap (included)
  • Chemical resistance data: resistant to oil, gasoline, water and aliphatics. Moderately resistant to acids, bases, solvents and ozone
  • Package contains: instruction manual, cap for radial cable output, spanner for preliminary stroke setting

TECHNICAL DATA

Order no.

| 5323010| 5323011| 5323013|

5323014

---|---|---|---|---
Product type| |

P2004 M

| P2004 T| P2004 U|

P2004 F

Measuring range|

mm

|

± 2

Measuring range|

inch

|

± .079”

Distance to upper stop|

mm…mm

|

+2.2 . . . 4.4

Distance to upper stop|

inch…inch

|

+ .09 … .173”

Distance to lower stop|

mm…mm

|

-2.2 . . . 0

Distance to lower stop|

inch…inch

|

-.09 … 0”

Lifter / retraction| |

Standard model

Measuring force|

N

|

0.75 N +/-0.15 N

Increase in measuring force|

N/mm

|

0.2 N/mm

Sensitivity deviation|

%

|

0.3

Repeatability fw|

µm

|

0.1

Repeatability fw|

inch

|

4 µ”

Hysteresis fu|

µm

|

0.5

Hysteresis fu|

inch

|

20 µ”

Linearity deviation within +/-0.5 mm|

µm

|

0.4

Linearity deviation within +/-.020”|

inch

|

16 µ”

Linearity deviation within +/-1.0 mm|

µm

|

1.5

Linearity deviation within +/-.039”|

inch

|

60 µ”

Linearity deviation within +/-2.0 mm|

µm

|

3

Linearity deviation within +/-.079”|

inch

|

120 µ”

IP protection category| |

IP 64

Cable length|

m

|

2.5

Temperature coefficient|

µm/°C

|

0.15

Compatibility| |

Mahr VLDT

| Tesa| Marposs|

Federa

Order no.

| g| Dimension f| a| b| c| d| e| f|

h

---|---|---|---|---|---|---|---|---|---
| |

inch

| mm| mm| mm| mm| mm| mm|

mm

5323010|

M 2.5

| | 88.7| 28| 21.3| 6| 9.2| 8|

14

5323011|

M 2.5

| | 88.7| 28| 21.3| 6| 9.2| 8|

14

5323013|

M 2.5

| | 88.7| 28| 21.3| 6| 9.2| 8|

14

5323014|

4/48 UNF

| 0.375| 88.7| 28| 21.3| 6| 9.2| |

14

Millimar P2004 MA / P2004 TA / P2004 UA / P2004 FA

Inductive Probe


FEATURES

  • Models with or without compressed-air (pneumatic) lifter or vacuum retraction
  • Measuring pin mounted in ball bearing guide
  • High linearity over the entire measuring range
  • Excellent electromagnetic shielding (EMC)
  • All probes can be easily converted from axial to radial by mounting a slip-on cap (included)
  • Chemical resistance data: resistant to oil, gasoline, water and aliphatics. Moderately resistant to acids, bases, solvents and ozone
  • Package contains: instruction manual, cap for radial cable output, spanner for preliminary stroke setting

TECHNICAL DATA

Order no.

|

5323020

| 5323021| 5323023|

5323024

---|---|---|---|---
Product type| |

P2004 MA

| P2004 TA| P2004 UA|

P2004 FA

Measuring range|

mm

|

± 2

Measuring range|

inch

|

± .079”

Distance to upper stop|

mm…mm

|

+2.2 . . . 4.4

Distance to upper stop|

inch…inch

|

+ .09 … .173”

Distance to lower stop|

mm…mm

|

-2.2 . . . 0

Distance to lower stop|

inch…inch

|

-.09 … 0”

Lifter / retraction| |

Vacuum lifter

Measuring force|

N

|

0.75 N +/-0.15 N

Increase in measuring force|

N/mm

|

0.2 N/mm

Sensitivity deviation|

%

|

0.3

Repeatability fw|

µm

|

0.1

Repeatability fw|

inch

|

4 µ”

Hysteresis fu|

µm

|

0.5

Hysteresis fu|

inch

|

20 µ”

Linearity deviation within +/-0.5 mm|

µm

|

0.4

Linearity deviation within +/-.020”|

inch

|

16 µ”

Linearity deviation within +/-1.0 mm|

µm

|

1.5

Linearity deviation within +/-.039”|

inch

|

60 µ”

Linearity deviation within +/-2.0 mm|

µm

|

3

Linearity deviation within +/-.079”|

inch

|

120 µ”

IP protection category| |

IP 64

Cable length|

m

|

2.5

Temperature coefficient|

µm/°C

|

0.15

Compatibility| |

Mahr VLDT

| Tesa| Marposs|

Federa

Order no.

| g| Dimension f| j| k| l| m| a| b| c| d| e| f| h| i
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
| | inch| mm| mm| mm| mm| mm| mm| mm| mm| mm| mm| mm|

mm

5323020|

M 2.5

| | 3.6| 9| 8.3| 12.5| 88.7| 28| 21.3| 6| 9.2| 8| 14|

26.5

5323021|

M 2.5

| | 3.6| 9| 8.3| 12.5| 88.7| 28| 21.3| 6| 9.2| 8| 14|

26.5

5323023|

M 2.5

| | 3.6| 9| 8.3| 12.5| 88.7| 28| 21.3| 6| 9.2| 8| 14|

26.5

5323024|

4/48 UNF

| 0.375| 3.6| 9| 8.3| 12.5| 88.7| 28| 21.3| 6| 9.2| | 14|

26.5