KOMSHINE KPM-35 Optical Power Meter User Manual

June 9, 2024
Komshine

KOMSHINE KPM-35 Optical Power Meter User Manual
KOMSHINE KPM-35 Optical Power Meter

External and key function description

External and key function description

  1. OPM interface: insert the fiber to be tested, test the optical power.
  2. LED lighting: flashlight lighting
  3. Display: display test results and other information
  4. λ key: can switch 7 test wavelengths
  5. LED button: turn on/off the flashlight, press any button to turn on the backlight
  6. REF/dB key: Short press the dB to switch unit, click once n W/dBm/dB to enter the upper clear data , press and hold until REF is displayed on the screen, and set the current optical power as reference value, enter the relative optical power test mode, the screen will display the settled reference.
  7. On/off key: turn the device on or off
  8. Auto Off
  9. wavelength
  10. Frequency
  11. Battery level
  12. Numerical value
  13. Unit

Power on/Auto power off

Short press the power button to turn on machine, and automatically start the auto-off function, the default auto-off time is 10 minutes. If you want to cancel this function, press and hold the power button .when starting up. When the power on icon disappears, it means to cancel the auto-off function.
Power on/Auto power off

Optical power reference value setting

Enter the optical power meter interface after booting, short press the “REF” key to set the current power value as the reference power, which can realize relative optical power test (insertion loss test) or absolute power test. After entering the relative power test mode, the insertion loss (dB) is displayed at the bottom of the screen, and the screen displays the reference value; short press the “dB” key to switch between linear power and absolute power display. The units of linear power, absolute power, and relative power are n W, dBm, and dB respectively.

  • P absolute power = 10lgP linear power / 1mW.
  • P relative power = P absolute power-P reference power.
    Optical power reference value setting

Optical power wavelength switching

On the optical power meter interface, short press the “λ” key to switch the measurement wavelength. You can choose 7 different test wavelengths, 850nm/980nm/1300nm/ 1310nm/1490nm/1550nm, 850nm, 1625nm. To ensure the accuracy of the test, the selected wavelength must be consistent with the wavelength of the measured optical signal
Optical power wavelength switching

LED lighting

Press the LED key to control the flashlight to turn on and off. Press any key to turn on the backlight.
LED lighting

Calibration function description

Press the LED+REF/dB keys at the same time to enter the calibration mode. Cal is displayed at the bottom of the screen. The  following operations are only valid in the calibration mode. 入 key for downward adjustment, REF/dB key for upward adjustment. After adjustment, press LED to save

Key Function
REF Increase by 0.1dB
λ Decrease by 0.1dB
Save
Shut down

Common fault solutions

Fault prompt Possible Causes Solutions
LCD display is weak Battery low Replace battery
Unable to boot display Battery low or other reasons Reboot or replace

battery
Optical power value is abnormal| Connector failure/dirty| Reconnect the connector or clean the sensor

Product introduction

KPM-35 optical power meter is widely used in the construction, maintenance, inspection and acceptance of opticalfiber communication network projects. The combination of fiber optic power meter & light source, check continuity, and help evaluate the transmission quality of optical fiber links. Smart appearance, sustainable backlit display, and friendly operation interface make you feel good about it. Provides 7 wavelengths detection, with automatic wavelength memory function. The ultra-wide optical power test range, precise test accuracy and new user self-calibration function will make your work even better. Universal interface design, support FC/SC/ST and other interfaces, without complicated conversion. In addition, the LED lighting function has been added to the product basis to allow it to be carried out in a dark environment, further improving work efficiency

Product features

  • 2.5mm universal interface+ SC

  • Wavelength range 850nm~1625nm

  • Manual calibration

  • Silica gel shell protection design, 2m anti-fall

  • ±0.2 dB accuracy

  • Measuring range:-70~+10dBm/-50~ +26dBm

  • Waterproof keys suitable for various outdoor environments

  • Equipped with LED lights to facilitate work in dark environments

  • SC
    Product features

  • FC

  • **ST

**

  • LC(Optional)

Product parameter

Wavelength(nm) 850/980/1300/1310/1490/1550/1625nm
Measuring range(dBm) -70~+10dBm/-50~ +26dBm
Connectors 2.5mm universal interface+SC
Power Supply Alkaline battery(3 AA 1.5V battery)
Resolution(dB) 0.01
Working Temperature -10~+60(℃)
Storage Temperature -25~+70(℃)
Dimensions/Weight 86x46x181mm / 364g
  • Use environment
  • Operating environment altitude: Area altitude below 2000m

Tips

Please read all instructions and warnings before using this product. Irregular use will cause damage to the product or personal safety

  1. Do not store this product in high temperature, strong light and strong magnetic fields, and do not place it in other harsh environments such as fire sources.
  2. Improper use of the product may easily cause the product damage or may endanger personal and property safety.
  3. If consumers violate the product manual and improperly use it, the personal and property damage caused by it will bearby yourselve, our company will not bear any legal responsibility.
  4. Non-professionals are strictly prohibited from disassembling this product.
  5. Avoid using electrical appliances or loads that exceed the output current of this product (the circuit will be protected and there will be no output).
  6. Avoid strong physical effects, including knocking, throwing, trampling, squeezing, etc.
  • Standard configuration
  • Packing carton, optical power meter , certificate of conformity, instruction manual.

QR Code
QR Code

Contact us

KOMSHINE TECHNOLOGIES LIMITED
Tel : +86 25 66047688
Email : info@komshine.com
Add: 2F Bldg. D Qinheng Tech. Pk. Nanjing, JS, 210001, China.
Website: www.KomShine.com

KOMSHINE Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals