StarTech RKCONS1716K 16-Port VGA Rackmount LCD Console User Guide
- June 9, 2024
- StarTech
Table of Contents
- StarTech RKCONS1716K 16-Port VGA Rackmount LCD Console
- Product Design
- Package Contents
- Requirements
- Installation
- Safety Measures
- FCC Compliance Statement
- Operation
- Industry Canada Statement
- Warranty Information
- Limitation of Liability
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
StarTech RKCONS1716K 16-Port VGA Rackmount LCD Console
Product Design
Actual product may vary from photos
Front View
- Handle
- Port Selection Buttons/LEDs
- Current Port
- Rail(s)
- Mounting Bracket (pre installed)
- Keyboard LEDs
- Display Menu Buttons
- Release Switch
Rear View
- Power Connection Port
- Power Switch
- Ground Connection Screw
- Console Mouse Port
- Console Keyboard Port
- Daisy Chain Port (not supported)
- USB-A Ports
- Console Monitor Port
- Host Port
Package Contents
- LCD Rackmount Console x 1
- KVM Cables x 16
- M5 Cage Nuts x 8
- M5 Screws x 8
- Regional Power Cords (NA, JP, EU, UK, ANZ) x 5
- Mounting Rails x 2
- Quick-Start Guide x 1
Requirements
- 1U of Rack Space
- Grounding Wire
- Power Source
- Up to 16 Computers or Servers
- Phillips Type Screwdriver
Requirements are subject to change. For the latest requirements, please visit www.StarTech.com/RKCONS1716K.
Installation
- Caution! Double pole / neutral fuse. Disconnect mains before servicing.
- Always ground the unit before connecting/disconnecting the Power Cord.
Mounting the LCD Rackmount Console
Note: It’s easier to install the LCD Rackmount Console if another person helps
you with the installation.
Warning: Use caution and proper lifting techniques when installing the LCD
Rackmount Console.
- Based on the mounting depth of the server rack that you are using, select the appropriate length of Mounting Rails.
- Decide where in the server rack you want to install the LCD Rackmount Console.
- Insert the M5 Cage Nuts (two per Mounting Post) into the square Mounting Holes on the Mounting Posts.
- Align the rear Mounting Bracket Rails with the M5 Cage Nuts on the corresponding Mounting Post.
- Insert an M5 Screw (two per Mounting Post) through the rear Mounting Bracket Rail and into the M5 Cage Nut. Do not tighten the M5 Screws.
- With assistance, slide the LCD Rackmount Console into the server rack guiding the rear Mounting Bracket Rails into the Rail Assembly.
- Insert a M5 Screw (two per Mounting Post) through the front Mounting Bracket Rail into the M5 Cage Nut.
- Use a Phillips Type Screwdriver to tighten the M5 Screws.
- Ensure that the rear Rails are properly aligned.
- Use a Phillips Type Screwdriver to tighten the M5 Screws.
Grounding the LCD Console
Notes: Grounding wires are typically green or green with a yellow stripe, and
should be at least 18 AWG.
Grounding is recommended in all environments and essential in environments
with high levels of electromagnetic interference
(EMI), or frequent electrical surges.
- Using a Phillips Head Screwdriver, loosen the Grounding Connection Screw.
- Attach the Grounding Wire to the shaft of the Grounding Connection Screw.
- Tighten the Grounding Connection Screw, making sure not to over-tighten.
- Attach the other end of the Grounding Wire (not connected to the LCD Rackmount Console) to a proper earth-ground connection.
Connect the Console
Important Considerations
- If you’re installing the Console in a closed or multi-unit rack assembly, ensure that the environmental conditions are within the unit’s maximum and minimum specifications.
- Consider your airflow requirement when selecting a location for installation.
- The Console should be installed with a balanced mechanical load.
- It’s recommended that the Console be connected to a power source with overcurrent protection and supply wiring.
- The Console should be grounded appropriately.
- Installation depth:
- Connect a Grounding Wire to the Ground Connection Screw on the LCD Rackmount Console and to the earth-ground connection.
- Connect one of the KVM Cables to a Computer or Server and the other one to the Host Ports on the LCD Rackmount Console. You can connect up to 16 computers or servers.
- Connect the appropriate Power Cord for your region to the Power Connection Port on the LCD Rackmount Console and to a Power Source.
- Open the LCD Rackmount Console. For more information about how to do this, see the “Open the Console” topic.
- Use the Power Switch to turn on the LCD Rackmount Console. Note: The LCD Rackmount Console makes two beeping sounds and the LED flashes three times when turned on.
- Turn on the connected Computers or Servers.
- On the Login screen on the LCD Rackmount Console, do one of the following:
- If you’re using the console for the first time or you haven’t set a username and password, leave the text fields blank and press Enter.
- If you have set a username and password, enter the
Safety Measures
- Wiring terminations should not be made with the product and/or electric lines under power.
- Product installation and/or mounting should be completed by a certified professional.
- Please note that the included power cables are for use with this product only and cannot be used with other electrical devices.
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
information in the corresponding text fields and press Enter.
Connect an optional monitor, keyboard, or mouse, connect the peripherals to
the corresponding ports on the console.
Disconnect the Console
- Power off the connected Computer, Server or KVM.
- Close the LCD Rackmount Console. For more information about how to do this, see the “Close the console” section.
- Use the Power Switch to turn off the LCD Rackmount Console.
Operation
Open the Console
-
Move the Release Switch to the unlocked position.
-
Use the Handle to pull the LCD Rackmount Console out towards you until you hear the LCD Rackmount Console click into place.
-
Pull the Display up and position it at the desired angle.
-
Disconnect the Power Cord from the Power Connection Port on the LCD Rackmount Console.
Note: Always disconnect the Power Cord before disconnecting the Grounding Wire. -
Disconnect the KVM Cable connected to a Computer, Server or KVM.
-
(Optional) Disconnect the Grounding Wire connected to the Ground Connection Screw on the LCD Rackmount Console.
Close the Console
- Lower the Display until it’s flush against the Keyboard.
- Slide the Release Switches on the LCD Rackmount Console forward and push the LCD Rackmount Console in towards the rear of the rack.
- Release the Switches and continue pushing the LCD Rackmount Console the rest of the way into the rack.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation. Changes or modifications not expressly
approved by StarTech.com could void the user’s
authority to operate the equipment.
Industry Canada Statement
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [B] est conforme à la norme NMB-003 du
Canada.
CAN ICES-3 (B)/NMB-3(B)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
Use of Trademarks, Registered Trademarks, and other Protected Names and
Symbols
This manual may make reference to trademarks, registered trademarks, and other
protected names and/or symbols of third-party companies not related in any way
to StarTech.com.
Where they occur these references are for illustrative purposes only and do
not represent an endorsement of a product or service by StarTech.com, or an
endorsement of the product(s)
to which this manual applies by the third-party company in question.
StarTech.com hereby acknowledges that all trademarks, registered trademarks,
service marks, and other protected names and/or symbols contained in this
manual and related documents are the property of their respective holders.
Warranty Information
This product is backed by a two-year warranty. StarTech.com warrants its products against defects in materials and workmanship for the periods noted, following the initial date of purchase. During this period, the products may be returned for repair, or replacement with equivalent products at our discretion. The warranty covers parts and labor costs only. StarTech.com does not warrant its products from defects or damages arising from misuse, abuse, alteration, or normal wear and tear.
Limitation of Liability
In no event shall the liability of StarTech.com Ltd. and StarTech.com USA LLP (or their officers, directors, employees or agents) for any damages (whether direct or indirect, special, punitive, incidental, consequential, or otherwise), loss of profits, loss of business, or any pecuniary loss, arising out of or related to the use of the product exceed the actual price paid for the product. Some states do not allow the exclusion or limitation of incidental or consequential damages. If such laws apply, the limitations or exclusions contained in this statement may not apply to you.
-
StarTech.com Ltd.
45 Artisans Crescent
London, Ontario
N5V 5E9
Canada -
StarTech.com LLP
4490 South Hamilton
Road
Groveport, Ohio
43125
U.S.A. -
StarTech.com Ltd.
Unit B, Pinnacle 15
Gowerton Road
Brackmills,
Northampton
NN4 7BW
United Kingdom -
StarTech.com Ltd.
Siriusdreef 17-27
2132 WT
Hoofddorp
The Netherlands
For manuals, FAQs, videos, drivers, downloads, technical drawings, and more, visit www.startech.com/support
References
- 16 Port Rackmount KVM Console w/17in LCD - KVM Consoles - Rackmount | StarTech.com
- You | Fabricant de cuisines aménagées & salles de bains sur-mesure
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>