TRANE ZN511 Tracer SC+ Building Automation System
Introduction
- The Tracer ZN511 and ZN521 zone controllers provide digital control for several types of heating, ventilating, and air-conditioning (HVAC) equipment.
- The Tracer ZN511 controls:
- Water-source heat pumps
- Fan coils
- Cabinet heaters
- The Tracer ZN521 controls:
- Unit ventilators
- Fan coils
- Cabinet heaters
- Blower coils
- Tracer zone controllers operate as standalone devices or as part of a Trane Integrated Comfort system (ICS). The[ controllers communicate with a Tracer Summit building automation system via a LonTalk communication link. LonTalk allows the controllers to operate in peerto-peer configuration and to communicate with other compatible [building control systems.
- Trane offers a variety of wall-mounted zone sensors for Tracer controllers. Zone sensors come with any of the following options:
- Temperature setpoint thumbwheel
- Fan speed switch
- ON and CANCEL occupancy buttons
- A communications jack for the Rover service tool
The Tracer ZN511 zone controller provides digital control of fan coils and water-source heat pumps. The Tracer [ZN511 improves comfort control and provides stand-alone or networked building automation.
Inputs and outputs
- Tracer ZN511 inputs and outputs include:
- Analog inputs: zone temperature, entering or leaving water temperature, discharge air temperature, zone temperature setpoint, fan mode switch
- Binary inputs: occupancy, condensate overflow, low water temperature, low pressure protection, high pressure protection
- Outputs: water-source heat pump: compressor 1, compressor 2, twoposition outside air damper, reversing valve, fan on/off Fan coil: fan high, fan medium, fan low, 1 cool, 1 heat, two-position outside air damper
- Generic points for use with a Tracer Summit building automation system: binary input (shared with occupancy), binary output (shared with outside air damper)
- The generic inputs pass information to the building automation system. They do not affect the operation of the unit. The generic binary output is controlled by the building automation system and its state is not changed by unit operation, even under a diagnostic shutdown.
Features
Easy installation
The controller can be installed in existing Trane and competitive HVAC
equipment without major wiring changes, and clearly labeled screw terminals
ensure that wires are connected quickly and accurately. A compact enclosure
design simplifies installation in minimal space.
Entering water temperature sampling
A traditional system using a two-way control valve on a fan coil might not
sense the correct entering water temperature during long periods when the
control valve is closed. The Tracer ZN511 solves this problem by opening the
valve for three minutes to allow the water temperature to stabilize before the
temperature is taken. This feature allows the use of two-way control valves to
provide accurate two-pipe system [changeover for 1heat/1 cool applications.
Automatic heat/cool mode determination
The Tracer ZN511 automatically determines whether heating or cooling is needed
to maintain comfort levels, without the need to manually adjust unit controls.
The controller measures the zone temperature and setpoint temperature, then
uses a proportional/ integral algorithm to maintain zone temperature at the
setpoint.
Occupied and unoccupied operation
The occupancy input works with a motion (occupancy) sensor or time clock. A
communicated value from a building automation system through the LonTalk
communication link can also be used. The input allows the controllers to use
unoccupied (setback) temperature setpoints.
Random start
This feature randomly staggers multipleunit start-up to reduce electrical
demand spikes.
Warm-up and cool-down
This feature is available with the installation of an outside air damper. If
the room temperature drifts too far from the setpoint, the controller
temporarily closes the damper to bring the temperature to the desired setpoint
as quickly as possible.
Manual output test
Pressing the test button on the controller exercises all binary outputs in
sequence. This feature is an invaluable troubleshooting tool.
Peer-to-peer communication
Multiple controllers can share data i they are bound together. Shared data can
include setpoint, zone temperature, mode, and fan status. Applications having
more than one unit serving a single large space can benefit from this feature,
which prevents multiple units from simultaneously heating and cooling.
Interoperability
The Tracer ZN511 conforms to the LonMark® Space Comfort Controller (SCC)
profile and communicates via the LonTalk protocol. This allows it to work with
other control systems that support LonTalk and the SCC profile.
Continuous fan or fan-cycling operation
Users can choose to have the fan run continuously at a given speed, or cycle
on and off automatically by selecting the AUTO mode.
Equipment protection
The Tracer ZN511 includes inputs that allow for the following equipment
protection:
- Refrigerant high- and low-pressure protection to prevent the unit from operating with high/low refrigeration pressure levels (heat pump only)
- Compressor minimum on and off timers to extend compressor life by preventing short cycling (heat pump only)
- A condensate overflow switch to prevent water damage to the building
- Low-temperature detection to prevent compressor operation during abnormal conditions (heat pump) or coil freeze-up (fan coil)
Timed override
The timed override function for after hours operation allows users to request
unit operation by the touch of a button on the unit zone sensor. Additionally,
users can press the CANCEL button at any time to place the unit back into
unoccupied mode.
Fan status
The controller monitors the fan output status as proof of airflow. This method
is cost effective and commonly used on
direct-drive fan applications.
Filter maintenance
Filter maintenance status is based on the cumulative hours of operation of the
unit fan. The controller has timers that can be reset, and when the time limit
expires, Tracer Summit software or the Rover service tool indicates that unit
maintenance is recommended.
Wiring diagram for the ZN511 zone controller
Tracer ZN521 zone controller
The Tracer ZN521 zone controller provides digital control of fan coils, unit ventilators, and blower coils. The Tracer ZN521 improves comfort control and provides stand-alone or networked [building automation.
Inputs and outputs
- Tracer ZN511 inputs and outputs include:
- Analog inputs: zone temperature, entering or leaving water temperature, discharge air temperature, zone temperature setpoint, fan mode switch
- Binary inputs: occupancy, condensate overflow, low water temperature, low pressure protection, high pressure protection
- Outputs: water-source heat pump: compressor 1, compressor 2, twoposition outside air damper, reversing valve, fan on/off Fan coil: fan high, fan medium, fan low, 1 cool, 1 heat, two-position outside air damper
- Generic points for use with a Tracer Summit building automation system: binary input (shared with occupancy), binary output (shared with outside air damper)
- The generic inputs pass information to the building automation system. They do not affect the operation of the unit. The generic binary output is controlled by the building automation system and its state is not changed by unit operation, even under a diagnostic shutdown.
Features
Easy installation
The controller can be installed in existing Trane and competitive HVAC
equipment without major wiring changes, and clearly labeled screw terminals
ensure that wires are connected quickly and accurately. A compact enclosure
design simplifies installation in minimal space.
Modulating control
The Tracer ZN521 provides exceptional comfort control through hydronic
valve and damper tri-state modulation and a proportional-integral control
algorithm.
Cascade control
Cascade control differs from zone temperature control in that the unit resets
the discharge air temperature to[ control the zone. Cascade control manages
zone temperature more effectively than zone temperature control, in which the
discharge air temperature can exceed comfort levels.
Entering water temperature sampling
Traditional equipment using a two-way control valve might not sense the
correct entering water temperature during long periods when the control valve
is closed. The Tracer ZN521 solves this problem by opening the valve for three
minutes to allow the water
temperature to stabilize before the temperature is taken. This feature allows
the use of two-way control valves to provide accurate two-pipe system
changeover for 1heat/1 cool applications.
Automatic heat/cool mode determination
The Tracer ZN521 automatically determines whether heating or cooling is needed
to maintain comfort levels, without the need to manually adjust unit controls.
The controller measures the zone temperature and setpoint temperature, then
uses a proportional/ integral algorithm to maintain zone temperature at the
setpoint.[
Occupied and unoccupied operation
The occupancy input works with a motion (occupancy) sensor or time clock. A
communicated value from a building automation system through the LonTalk
communication link can also be used. The input allows the controllers to use
unoccupied (setback) temperature setpoints.
Random start
This feature randomly staggers multipleunit start-up to reduce electrical
demand spikes.
Warm-up and cool-down
This feature is available with the installation of an outside air damper. If
the room temperature drifts too far from the setpoint, the controller
temporarily closes the damper to bring the temperature to the desired setpoint
as quickly as possible.
Manual output test
Pressing the test button on the controller exercises all binary outputs in
sequence. This feature is an invaluable troubleshooting tool.
Peer-to-peer communication
Multiple controllers can share data if they are bound together. Shared data
can include setpoint, zone temperature, mode, and fan status. Applications
having more than one unit serving a single large space can benefit from this
[feature, which prevents multiple units from simultaneously heating and
cooling.
Interoperability
The Tracer ZN521 conforms to the[ LonMark® Space Comfort Controller (SCC)
profile and communicates via the LonTalk protocol. This allows it to work with
other control systems that support LonTalk and the SCC profile.
Interoperability
The Tracer ZN521 conforms to the LonMark® Space Comfort Controller (SCC)
profile and communicates via the LonTalk protocol. This allows it to work with
other control systems that support cLonTalk and the SCC profile.
Equipment protection
The Tracer ZN521 includes inputs that allow for the following equipment
protection:
- A condensate overflow switch to prevent water damage to the building
- Low-temperature detection to help prevent coil freeze-up
- Discharge air temperature limiting to help prevent the coil from freezingThe Tracer ZN521 includes inputs that allow for the following equipment protection:
- A condensate overflow switch to prevent water damage to the building
- Low-temperature detection to help prevent coil freeze-up
- Discharge air temperature limiting to help prevent the coil from freezing
Automatic fan speed reset
Units set to AUTO operate at the default fan speeds (cooling and heating may
have different default speeds). If the default fan speed is high, medium, or
low, the unit operates accordingly. If the default fan speed is set to AUTO,
the fan operates at low speed most of the time. If the temperature exceeds the
setpoint by more than 2°F (1°C), the controller changes the fan speed to
medium or high. This allows the unit to operate at low speed whenever
possible.[
Automatic ventilation reset
Because ensuring proper ventilation[ rates is so important for indoor air
quality, the Tracer ZN521 is configured with two outside/fresh air damper
minimum position setpoints for occupied operation. As the fan speed changes,
the damper minimum position changes to maintain the correct ventilation rate.
Fan status
The Tracer ZN521 has two methods of monitoring fan status. The first method[
monitors the fan output status on the unit controller. This method is
typically used with direct fan applications. The controller can also accept a
binary [input from a fan proof switch for belt driven applications. When fan
operation is expected by the controller but not confirmed by the proof switch,
a diagnostic message is generated and unit operation is disabled.
Filter maintenance
Filter maintenance status is based on the cumulative hours of operation of the
unit fan. The controller has timers that can be reset, and when the time limit
expires, Tracer Summit software or the Rover service tool indicates that unit
maintenance is recommended.
Water valve override
This function causes all of the water valves in every unit to open
simultaneously at a command from Tracer Summit software or the Rover service
tool. This function reduces the [time required for balancing the water
distribution system.
Relative humidity input
An analog input can be configured as a relative humidity input. The controller
can use this value to support the dehumidification function.
Active dehumidification
This feature keeps relative humidity levels within ASHRAE 62-89R guidelines
[to maximize comfort and minimize the risk of microbial growth and damage to
[the building or furnishings due to humidity. The controller can provide
active dehumidification when the equipment includes a reheat coil and a
humidity sensor.
CO2 input
An analog input can be configured to measure CO2. Tracer Summit can use [the
input in a variety of applications. This input has no direct effect on the
operation of the controller.[[
Two-stage electric heat
- The Tracer ZN521 supports 1- or 2-stage electric heat operation for heating. To control the zone temperature, electric heat is cycled to control the discharge air temperature. The rate of cycling is dependent on the load in the space and the temperature of any incoming freshair from the economizer.
- Two-pipe changeover units with electric heat use electric heat when hot water is not available.
Economizing control
When the Tracer ZN521 is configured for economizing control, it opens the
outdoor damper to the calculate position to provide “free” cooling as
required. If the damper is completely open and the setpoint is still not
achieved, the cooling valve opens to satisfy load requirements. As cooling
load requirements decrease, the valve closes until the setpoint is reached or
the damper reaches its adjustable minimum position.
Wiring diagram for the ZN521 zone controller
Network architecture
- Tracer zone controllers, shown in Figure 3, can operate on a Tracer Summit building automation system, on a peer-to-peer network, or as standalone devices.
- The Rover service tool can configure the controllers through the communication jack in a zone sensor or at any accessible location on the LonTalk communication link.
Zone sensor options
Zone sensors are available in a variety of configurations. Table 1 describes Trane zone sensors available for Tracer zone controllers. Figure 4 shows three types of zone sensors for the Tracer ZN511 and ZN521 zone controllers.
BAS order number
|
Use
| Fan| Zone| Timed override buttons|
Comm jack
---|---|---|---|---|---
High| Med| Low| Auto| Off| Setpoint
thumbwheel| Temperature sensor| On| Cancel
4190 1087| Any| | | | | | | x| | |
4190 1088| Any| | | | | | | x| x| x| x
4190 1090| Heat pump| | | | | | x| x| x| x| x
4190 1094| Heat pump| | | | | | x| x| | | x
4190 1095| Unit vent| x| | x| | x| x| x| x|
x| x
4190 1115| Fan coil| x| x| x| x| x| x| x|
x| x| x
4190 1116| Unit vent| x| | x| x| x| x| x|
x| x| x
4190 1117| Any| | | | x| x| x| x| x| x| x
Dimensions and specifications
Dimensions
(See Figure 2)
- Height: 5 3/8 in. (137 mm)
- Width: 6 7/8 in. (175 mm)
- Depth: 2 in. (51 mm)
Power
- Supply: 19–30 Vac (24 Vac nominal) at 50/60 Hz
- Consumption: 14 VA plus 12 VA (maximum) per binary output
Operating environment
- Temperature: From 32 to 140°F (0 to 60°C)
- Relative humidity: From 5 to 95% noncondensing
Storage environment
- Temperature: From –40 to 185°F (–40 to 85°C)
- Relative humidity: From 5 to 95% noncondensing
Agency listings/compliance
-
CE—Immunity:
- EN 50082-1:1997
- EN 50082-2:1995
-
CE—Emissions:
EN 50081-1:1992 (CISPR 22) -
UL and C-UL listed: Energy management system
-
UL 94-5V (UL flammability rating for plenum use)
-
FCC Part 15, Class A
-
LonMark® Space Comfort Controller (SCC) profile
ABOUT COMPANY
- The Trane Company
- An American Standard Company www.trane.com
- For more information contact your local district office or e-mail us at comfort@trane.com
Since The Trane Company has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>