Tough Leads 10mA RCD Conversion Kit Instructions

June 3, 2024
Tough Leads

Tough Leads 10mA RCD Conversion Kit

Fitting Instructions

Step 1 – Remove the cable from the current plug RCD:

  •  Unscrew the cover.
  • Remove the cord grip.
  • Unscrew the terminals.
  • Remove the wires.

Step 2 – Fit the new inline RCD:

  • Unscrew the RCD cover whcih is at the opposite end to the plug.
  • Remove the cord grip.
  • Ensure all 3 terminals are loosened.
  • Push the cable into the RCD gland. A small amount of lubricant may be necessary.
  • Insert the brown wire into the terminal marked ‘L’.
  • Insert the blue wire into the terminal marked ‘N’.
  • Insert the green/yellow wire into the terminal marked ‘E’.
  • Ensure all terminals are tight – loose connections can lead to over heating.
  • Push the cable flex into the RCD, so that 3-4mm is showing past the position of the cord grip.
  • Screw down the cord grip. Tug the cable to ensure that it is tightly held in place.
  • Ensure that the wires are lying in a position where they will not be trapped or damaged by the cover.
  • Place the cover onto the RCD and screw down.

Operating Instructions

  •  Plug in the 13A plug to a suitable 13A socket.
  • Press the ‘RESET’ button.
  • The RCD will latch on, and remain so until the power supply to the RCD is turned off.
  • Press the ‘TEST’ button regularly to check for correct operation. After ‘TEST’, press the ‘RESET’ button.

Specification

  • Voltage: 230v
  • Current: 13A
  • Trip current: 10mA
  • Weaterproof rating: IP66 (protected against powerful water jets from any angle).