Cell2 UR04 Led Flush Mount Kit User Guide

June 9, 2024
Cell2

UR04 Led Flush Mount Kit
User Guide

CONTENTS

Cell2 UR04 Led Flush Mount Kit - Figure 1

WIRING & FUNCTIONS

Cell2 UR04 Led Flush Mount Kit - Figure 2

OPERATION

For Simultaneous or Alternating Synchronization:

  1. Apply +VDC to RED and YELLOW wires simultaneously to enter Flash Mode Selection.

  2. Remove YELLOW wire from +VDC and momentarily apply to +VDC to change mode selection:
    Mode 1 = Head 1 & 2 flash alternately
    Mode 2 = Head 1 & 2 flash simultaneously

  3. Exit Flash Mode Selection by removing +VDC.
    For Flash Pattern Selection:
    Momentarily apply +VDC to YELLOW wire
    Once to next pattern
    Quick three times to FP#1 (see Flash Pattern Chart)

FP# Flash Patterns
1 Single [2Hz]
2 Double [R65]*
3 Triple [2Hz]
4 Quad [2Hz]
5 Random
6 Single
7 Double
  • Actual approval will be based on the model purchased.
    ** In Mode 2, lightheads will both steady-burn; in Mode 1, one lighthead will steady burn while the other does double flash.

INSTALLATION – FLUSH MOUNT

  1. Select a mounting location and drill one 1″ (25.4mm) cut-out.
    NOTE: Mounting surface thickness @ 0.8~2.0mm
    Cell2 UR04 Led Flush Mount Kit - Figure 3

  2. From the front, install MOUNTING GROMMET onto the cut-out, and then insert the LIGHTHEAD.
    Cell2 UR04 Led Flush Mount Kit - Figure 5

  3. Ensure that triangle mark on the lens is aligned vertically.
    Cell2 UR04 Led Flush Mount Kit - Figure 4

  4. Where necessary, apply silicone around the reverse side to prevent from rotating.
    Cell2 UR04 Led Flush Mount Kit - Figure 6

INSTALLATION – BRACKET MOUNT (sold-separately)

  1. From the front, install the MOUNTING GROMMET onto the BRACKET, and insert the LIGHTHEAD.
    Cell2 UR04 Led Flush Mount Kit - Figure 7

  2. Ensure that triangle mark on the lens is aligned vertically.
    Cell2 UR04 Led Flush Mount Kit - Figure 8

  3. Secure the LIGHTHEAD onto the BRACKET with a screw.
    Cell2 UR04 Led Flush Mount Kit - Figure 9

  4. Secure the BRACKET onto the desired mounting surface with screws.
    Cell2 UR04 Led Flush Mount Kit - Figure 10

WIRING 2 KITS TOGETHER

Below is a schematic diagram for wiring 2 kits together.
YELLOW wires from both controllers must be connected together for synchronization.

  • If Mode 1 is selected: Head 1A&2A will flash alternately with Head 1B&2B.
  • If Mode 2 is selected: All Heads will flash simultaneously.
  • Refer to Flash Pattern Chart on the opposite page.

NOTE: To have Head 1A&2B alternate with 1B&2A, simply reverse the lighthead outlets on one of the Controllers; (both kits must be in Mode 1).

Cell2 UR04 Led Flush Mount Kit - Figure 11

NOTE: The mounting area varies from vehicle to vehicle. (The diagram is not drawn to scale)