king ECO2S Series Unit Heater User Manual

June 9, 2024
KING

Electronic Furnace KF/KFS ECO2S Series
User Manual

ECO2S Series Unit Heater

KFS 24 20 1 2S1 ECM
A B C D E F

A: Series
B: 24 – 240V 20 – 208V
C: Kilowatts
D: 1-phase 3-phase
E: 2 Stage 2S1= 2 Stage 1-phase 2S3= 2 Stage 3-phase
F: ECM Motor

  • Energy efficient ECM motor
  • 2-Stage comfort heating 15% Savings
  • Heavy duty open coil elements
  • Sequenced heating elements
  • Down flow or up flow
  • 16” x 20” x 1” inlet filter
  • Welded cabinet design
  • Horizontal or vertical mount
  • Mobile home approved
  • Breaker disconnects
  • Baked enamel finish
  • Extended life
  • Standard 24 volt control
  • Fan only relay
  • Quiet sound insulated cabinet
  • Year limited warranty

The KFS ECO2S Electric Furnace
ENERGY SAVINGS meets MAXIMUM COMFORT with the ECM Motor & 2 Stage Heating
The ECO2S Series Model adds a state of the art electronically controlled motor and 2 heating stages for added comfort and Maximum
Energy Savings. The KFS ECO2S Series furnace is the quietest and most compact unit available in its class. Ideal for residential applications, and yet powerful enough for commercial and process heating applications as well. It’s the perfect choice for both new and replacement installations.
The compact design allows it to be installed in either upflow, downflow or horizontal applications. Featuring a maintenance free blower, an insulated cabinet for quiet operation, and heavy gauge coiled nickel-chromium wire heating elements, the KFS furnace will provide years of trouble-free operation.

Motor Features

  • Energy Saver
  • AFUE 100% (Energy Guide Rating) Most Efficient
  • 3 speeds available
  • Designed for extended life
  • Efficiency up to 80%
  • 60 second time delay
  • Up to 33% greater efficiency with ECM motor
  • Up to 200% greater efficiency with Endura Pro motor in constant fan mode

Heating Features

  • 2-Stage Elements & control
  • Ni-Chrome Elements
  • More even heating

TWO STAGE COMFORT Why 2 Stage is Better
2 Stage controlled Furnaces allow you to use less energy during mild Spring and Fall temperatures. It’s like having a smaller furnace installed just for spring and fall, then when winter hits you have the reserve power of the second heating stage to fight off the cold weather. It also has the benefit of creating more even comfort temperatures.
Note: The Furnace will run a percentage longer to reach the room temperature so the ECM motors efficiency is key to getting the most out of your Furnace.

king ECO2S Series Unit Heater - 3

The ECO2S Series is more efficient and will save you up to 33% more per year versus standard furnace motors

  • Designed for extended life
  • Energy efficient
  • Improved reliability
  • Cooler operating temperature
  • 3 speeds
  • 15% 2 Stage

king ECO2S Series Unit Heater - 4

Ordering Information- single phase

king ECO2S Series Unit Heater - 5

Ordering Information- three phase

king ECO2S Series Unit Heater - 6

Accessories

MODEL UPC DESCRIPTION WEIGHT(lbs.)
KFS-4PJB 20185 * 4-Pole Jumper Bar – 15kW to 20kW .05
KFS-6PJB 20184 * 6-Pole Jumper Bar – 25kW        to 30kW .05
KFSSB 20182 Outlet Collar ( To provide 1” clearance for combustible floors)

5
KFS-Q02C| 20181| Small Cooling Cabinet 16″ L x 22″ W x 19½” H – 13 lbs.| 25
KFS-Q03C| 20180| Large Cooling Cabinet 18″ L x 22″ W x 19½” H – 15 lbs.| 25
KFS-DT| 20186| Transition from 14″ x 14″ Outlet to 12″ round| 25
DIMENSIONAL| CLEARANCE
---|---
Cabinet Sides| 1 in.
Cabinet Front| 0 in.
Exhaust duct within 3 feet of furnace| 1 in.
Return Air Plenum| 0 in.

Factory Installed Options

ADD SUFFIX: DESCRIPTION
-DS32 32 Amp, 3-Pole Disconnect Switch w/ Padlock Provision
-DS63 63 Amp, 3-Pole Disconnect Switch w/ Padlock Provision
-DS80 80 Amp, 3-Pole Disconnect Switch w/ Padlock Provision
-DS100 100 Amp, 3-Pole Disconnect Switch w/ Padlock Provision
-3/4HP Sub 3/4HP Motor for 20kW & 25kW Models Only

king ECO2S Series Unit Heater - 7

Dimensional Data

king ECO2S Series Unit Heater - 8

The height of the KFS furnace is the only dimension that changes.
Please refer to selection chart to determine the size of the unit.
Air Flow Chart (For 4 to 17.25kW Units with 1/3HP ECM Motor)

king ECO2S Series Unit Heater - 9

A Represents the voltage, 20=208V, 24=240V, 48=480V. Voltage of the KF/KFS unit does not affect the data in this table.
B NR= Not Recommended, Temperature Rise is above maximum design parameter.
C The highlighted cells are the factory default torque setting for each model. The ECM motor has 5 field adjustable torque settings, allowing for a wide range of design choices.
D (1) = Stage 1 Torque Settings (2) = Stage 2 Torque Settings / (2) = Default for Single Stage KFUH E Blower: 10” diameter, 8” wide
Air Flow Chart (For 20 to 25kW Units with 1/2HP ECM Motor)**

king ECO2S Series Unit Heater - 10

A Represents the voltage, 20=208V, 24=240V, 48=480V. Voltage of the KF/KFS unit does not affect the data in this table.
B NR= Not Recommended, Temperature Rise is above maximum design parameter.
C The highlighted cells are the factory default torque setting for each model. The ECM motor has 5 field adjustable torque settings, allowing for a wide range of design choices.
D (1) = Stage 1 Torque Settings (2) = Stage 2 Torque Settings / (2) = Default for Single Stage KFUH E Blower: 10” diameter, 8” wide
Air Flow Chart (For 20 to 25kW Units with OPTIONAL 3/4HP ECM Motor)**

king ECO2S Series Unit Heater - 11

A Represents the voltage, 20=208V, 24=240V, 48=480V. Voltage of the KF/KFS unit does not affect the data in this table.
B NR= Not Recommended, Temperature Rise is above maximum design parameter.
C The highlighted cells are the factory default torque setting for each model. The ECM motor has 5 field adjustable torque settings, allowing for a wide range of design choices.
D (1) = Stage 1 Torque Settings (2) = Stage 2 Torque Settings / (2) = Default for Single Stage KFUH E Blower: 10” diameter, 8” wide
Air Flow Chart (For 30 to 35kW Units with 3/4HP ECM Motor)**

king ECO2S Series Unit Heater - 12

A Represents the voltage, 20=208V, 24=240V, 48=480V. Voltage of the KF/KFS unit does not affect the data in this table.
B NR= Not Recommended, Temperature Rise is above maximum design parameter.
C The highlighted cells are the factory default torque setting for each model. The ECM motor has 5 field adjustable torque settings, allowing for a wide range of design choices.
D (1) = Stage 1 Torque Settings (2) = Stage 2 Torque Settings / (2) = Default for Single Stage KFUH
E Blower: 10” diameter, 8” wide
Internal Diagram – exploded view
Smart Heating Solutions**

king ECO2S Series Unit Heater - 13

Engineering Specifications

Contractor shall supply and install KFS ECO2S Series electric furnaces manufactured by King Electrical Mfg. Company. Furnaces shall be of the wattage and voltage as indicated on the plans.
Transformer: Each furnace is equipped with a heavy duty low voltage (40 VA) transformer for the thermostat control circuit.
Time Delay Sequencer: Actuates heating element banks to minimize electrical surges in compliance with E.E.I. and N.E.M.A. standards.
Heating Elements: Quick heating, long life Ni-Chrome elements are sized to provide proper watt density for maximum heat dissipation.
Terminal Block: For field wiring (optional special order) KFSTB Single Strike Connection. Takes multiple circuits into a single feed.
Air Filter: Convenient access for replacement of standard 16” x 20” x 1” filter. Do not use pleated filters.
Motor: Energy Saving, Long life, thermally protected, permanently lubricated, direct drive ECM motor—no belts to adjust or slip.
This low noise, 3 speed motor is designed for use with air conditioning capability as well as heating. Very quiet operating. 60 second fan delay.
Overcurrent Protection: 208 and 240 volt KFS models have 60 amp circuit breakers.
Limit Control: Integral automatic high temperature limit control in each heating element bank prevents the delivery of air at unsafe temperatures. 20-35 KW models use a manual reset limit control to completely shut the furnace off should an unsafe temperature occur. Summer fan only operation. Fan can be run independently from heating.
Mobile Home approved.
Unique Fan Orifice: Louver directs air over all heating elements and side walls evenly ensuring longer life performance.
Low Voltage Terminal Block: 24 Volt control screw terminals.
Approvals: cULus (E48864) USA and Canada

King Electrical Manufacturing Company
9131 10th Avenue South, Seattle, WA 98108
phone 206.762.0400
fax 206.763.7738
www.king-electric.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

KING User Manuals

Related Manuals