Lucid FR-W2304 Matte Black Blades Downrod Ceiling Fan Instruction Manual
- June 9, 2024
- LUCID
Table of Contents
FR-W2304 Matte Black Blades Downrod Ceiling Fan
Lucid
Installation Instructions
works with the Google Assistant
Please read and save these instructions
before installation
DO NOT RETURN TO STORE
2 Lucid Instructions
FR-W2304-62L
General Inquiries
For all questions about your ceiling fan please read all included
instructions, installation procedures, troubleshooting guidelines and warranty
information before starting installation.
For missing parts or general inquiries call our trained technical staff at:
1-866-810-6615 option 0 MON-FRI 8AM-8PM
EST Email: customerservice@modernforms.com Or live chat at modernforms.com
Fan Support
For fast service have the following information below when you call: 1. Model
Name and Number 2. Part Number and Part Description 3. Date Of Purchase and
Purchase Location
1-866-810-6615 option 1 MON-FRI 8AM-8PM
EST Email: fansupport@modernforms.com
FR-W2304-62L
Lucid Instructions 3
Safety Rules
For operation, maintenance, and troubleshooting information, visit
http://modernforms.com/fan-support/
To reduce the risk of electric shock, ensure electricity has been turned off
at the circuit breaker before beginning. All wiring must be in accordance with
the National Electrical Code “ANSI/NFPA 70” and local electrical codes.
Electrical installation should be performed by a licensed electrician.
The fan must be mounted with a minimum of 7 ft. (2.1m) clearance from the
trailing edge of the fan blades to the floor and a minimum of 1.5 ft (0.5m)
from the edge of the fan blades to the surrounding walls. Never place objects
in the path of the fan blades. To avoid personal injury or damage to the fan
and other items, please be cautious when working around or cleaning the fan.
To avoid electrical shock or damage to the motor or finish, do not use water
or chemicals when cleaning the fan or fan blades. A dry cloth or lightly
dampened cloth will be suitable for most cleaning.
After making electrical connections, spliced conductors should be turned
upward and pushed carefully up into the outlet box. The wires should be spread
apart with the grounded conductor and the equipment-grounding conductor on one
side of the outlet box, and the ungrounded conductor on the other side of the
outlet box.
All set screws must be checked and re-tightened where necessary before
installation.
4 Lucid Instructions
FR-W2304-62L
WARNING: Do not install or use your fan if any part(s) is/are damaged or
missing. This product is designed for use only with the supplied parts and/or
accessories designated for use with this product by Modern Forms. Substitution
of parts or accessories not designated for use with this product by Modern
Forms could result in personal injury or property damage and will void the
warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing. WARNING: To reduce the risk of electric shock, this fan
must be installed and operated with the supplied wall control, or controlled
from the Modern Forms app. WARNING: Do not use power tools to assemble or
install your fan. Using power tools can result in improper assembly which can
lead to noise or fan damage,personal injury or property damage. WARNING: To
reduce the risk of personal injury, do not bend the blade arms when installing
the brackets, balancing the blades or cleaning the fan. WARNING: Do not insert
foreign objects between rotating fan blades. WARNING: Do not operate fan
unless fan blades are in place. Noise and fan damage can occur WARNING: This
appliance is not intended for use by young children without supervision.
WARNING: To reduce the risk of fire, electric shock, personal injury or damage
to the fan or other items, the outlet box and support structure must be
securely mounted and capable of reliably supporting a minimum of 35 Ibs (15.9
kg). Use only UL/cUL listed outlet boxes marked “FOR FAN SUPPORT.” Use only
the screws and washers provided with the outlet box.
CAUTION: Before assembling your fan, refer to the “Making the Electrical
Connections” section. If you feel you do not have enough wiring knowledge or
experience, have your fan installed by a licensed electrician.
NOTE: Before servicing or cleaning the fan, switch power off at the circuit
breaker.
FR-W2304-62L
Lucid Instructions 5
Get Smart…
Integrates seamlessly with:
devices you already own
works with the Google Assistant
Premium smart features:
complement high quality materials
Wet Location-listed to the strictest UL/cUL safety regulations. Finished and
rated for interior and exterior use
Wi-Fi and Bluetooth enabled
DC
MOTOR
Quiet, reliable, and up to 70%
Accessories:
personalize your experience
Bluetooth Remote Control Dims light to 1% | ON/OFF 6 fan speeds F-RCBT-WT
White
Bluetooth Wall Control Dims light to 1% | ON/OFF 6 fan speeds | Sold
separately F-WCBT-WT White
6 Lucid Instructions
FR-W2304-62L
Contents
1. Mounting Options 2. Installing the Mounting Bracket 3. Attaching the Fan Blades 4. Installing the Adapter Plate 5. Hanging the Fan 6. Making the Electrical Connections 7. Installing the Optional Wall Control 8. Finishing the Installation 9. Installing the LED Luminaire Module 10. Controlling the Fan 11. Reset 12. Breeze Mode 13. Application 14. Accessories 14. Troubleshooting
10 12 12 14 14 18 20 22 24 26 28 28 28 30 32-34
Tools Required
FR-W2304-62L
Lucid Instructions 7
Package Contents
1. Blade Set of 5 RPL-F2304-62-BD-**
7. Adapter Plate RPL-F2304-ADP-**
2. Hanger Assembly Mounting Bracket Downrod Assembly: 6-inch Hanger Assembly
RPL-HGR-ASM-6-
3. Canopy w/Canopy Ring RPL-CAN-RND-
4. Coupling Cover RPL-F2304COUCVR-**
8. LED Module F4IN-120V-R1-30
9. Control Receiver w/Hardware F-R3-2304-062
10. PC Shade RPL-F2304-GLA
11. Remote Control F-RCBT-WT
5. Motor Assembly
6. Blade Holder Set (Upper and Lower) denotes finish code of fan RPL- F2304BLDHDER
Hardware Bag RPL-F2304-PARTS
10 x 38mm Pan Head Phillip Screws (2) 5 x 14 x 1mm Flat Washer (2)
3/16″ Star Washer (2)
Attach the ABS blade to upper blade holder 3/16″ x 9mm (16)
Attach the upper blade holder to lower blade holder 3/16″x 8mm (16)
D: Attach the upper + lower blade holder to motor housing 3/16″x16mm (16)
E: Safety Cable 6.5x19x2mm Flat Washer (1)
3/16″( 5.2×8.4×1.0mm) Spring Washer (1)
10x76mm Pan Head Phillip Wood Screws (1)
F: Wire Connectors (8) (included with receiver)
G: LED Screws (3) 5/32″ x 1/4″ Philip head screws (4)
*Each hardware bag comes with 1 spare screw Before discarding packaging materials be certain all parts have been removed. Place the parts from the hardware bag into a small container to keep them from being lost.
8 Lucid Instructions
FR-W2304-62L
2 3 4 5 6
FR-W2304-62L
Hanging Weight: 17 lbs IMPORTANT: Please make note of
the MAC ID on the receiver and keep it in a safe place.
1
7 8 9 10
11
Lucid Instructions 9
MAC ID
1. Mounting Options
CAUTION: To prevent electrical shock, ensure electricity has been turned off
at the circuit breaker before beginning.
If there isn’t an existing UL/cUL listed outlet box, please refer to the
following instructions. Secure the outlet box directly to the building
structure. Use appropriate fasteners and building materials. The outlet box
and support structure must be able to fully support the moving weight of the
fan (at least 35 lbs/15.9 kg). Do not use plastic outlet boxes. Use only
UL/cUL listed outlet boxes marked “FOR FAN SUPPORT.” Use Hardware A if needed
to mount your outlet box
Secure the outlet box directly to the building structure. Figures 1-1C are
examples of different ways to mount the outlet box.
NOTE: To hang your fan where there is an existing fixture but no ceiling
joist, you may need an installation hanger bar.
NOTE: Downrod fans can be suspended up to a maximum recommended length of 72″
using additional downrods (sold separately) and the included 80″ lead wire.
NOTE: The sloped ceiling kit (sold separately) is required for sloped ceiling
applications, and will accommodate slopes up to 45° (Fig. 1B).
NOTE: You may need a longer downrod to maintain proper blade clearance when
installing on a steep, sloped ceiling (Fig. 1B).
10 Lucid Instructions
FR-W2304-62L
1
3 1A
1 2
1 1B
1
3
2
1C
1
FR-W2304-62L
1. Support Brace 2. Outlet Box 3. Joist
1. Outlet Box
Support Ceiling Max 30° Angle 1. Support Brace 2. Mounting Bracket 3. Recess
Outlet Box
1. Outlet Box
Lucid Instructions 11
2. Installing the Mounting Bracket
Remember to turn off power at the breaker. Follow the steps below to hang your
fan properly:
1. Disconnect power at the breaker to the fan location. 2. Remove 1 of 2
screws from the bottom of mounting bracket and
save for use in Finishing the Installation section. Loosen the other screw
(Fig. 2). 3. Pass the 120-volt supply wires through the center hole in the
ceiling mounting bracket as shown in (Fig. 2A). 4. Secure the mounting bracket
to the ceiling outlet box with the screws and washers provided with your
outlet box (Fig. 2A).
3. Attaching the Fan Blades and Blade Arms to the Motor Housing
1. Attach the fan blades to the lower blade arm using the included screws.
(Fig. 3)Use Hardware B.
2. Attach the upper blade arm to the fan blades – connecting the lower and
upper blade arms. (Fig. 3) Use Hardware C.
3. Insert the blade sets into the motor housing and secure them to the motor
housing. (Fig. 3A) Use Hardware D.
12 Lucid Instructions
FR-W2304-62L
2
1 2 1. Mounting Bracket 2. Screw
3
2A
2 1
3
4
1. 120V Wires 2. cUL/UL Listed Outlet Box 3. Mounting Bracket 4. Mounting
Screws
(supplied with outlet box)
3A
x 5 set
FR-W2304-62L
x 5 set
Lucid Instructions 13
4. Installing the Adapter Plate
1. Remove one of the three mounting plate screws from the mounting ring and
loosen the other two screws (Do not remove) (Fig. 4).
2. Place the key holes in the adapter plate over the two screws previously
loosened from the mounting ring. Turn the light kit plate until it locks in
place at the narrow section of the key holes (Fig. 4A).
3. Securely tighten the two previosly loosened screws and install the one
screw that was removed.
5. Hanging the Fan
1. Take out the set screw located in the hanger ball, lower the hanger ball
and remove the cross pin. Remove the hanger ball from the hanger ball/ downrod
assembly (Fig. 5).
2. Remove the clevis pin and cotter pin, and loosen the two collar screws
from the motor collar (Fig. 5).
3. Carefully feed the motor wires and safety cable up through the downrod.
Thread the downrod into the collar.
4. Align the holes of downrod and collar and insert the cotter pin and clevis
pin. Tighten the two collar screws (Fig. 5).
WARNING: Failure to properly install the cotter pin and/or tighten the screws
could result in the fan loosening and possibly falling.
14 Lucid Instructions
FR-W2304-62L
4
4A
180
5
FR-W2304-62L
Lucid Instructions 15
5. Hanging the Fan (cont.)
1. Slip the coupling cover, canopy screw cover (painted side face down), and
canopy (opened side up) onto the downrod (Fig. 5A). Coupling cover goes all
the way to the bottom.
2. Carefully reinstall the hanger ball onto the downrod, being sure that the
cross pin is in the correct position, the setscrew is tightened and wires are
not twisted (Fig. 5A). Use Hardware F.
3. Carefully lift the fan motor assembly up to the mounting bracket and seat
the hanger ball in the mounting bracket socket. Make sure the tab on the
mounting bracket socket is properly seated in the groove in the hanger ball
(Fig. 5A). Rotate the socket assembly until the ball drops and locks into the
hanger bracket screw.
4. Secure the safety cable into the structure beams using the wood screw,
washers, and spring washers provided (Fig. 5B). Use Hardware E.
NOTE: A Safety cable is required for all installations in Canada. Safety cable
is required for ceiling fan and light combinations over 35 lbs. in both flush
and downrod models in the United States.
16 Lucid Instructions
FR-W2304-62L
5A 5B
FR-W2304-62L
Lucid Instructions 17
6. Making the Electrical Connections
WARNING: Installation of this fan requires that a three-conductor cable
(including ground wire) which should run between ceiling and wall outlet box.
WARNING: Check to see that all connections are tight, including ground, and
that no bare wire is visible at the wire nuts, except for the ground wire. Use
Hardware F.
Insert the receiver into the mounting bracket with the flat side of the
receiver facing the ceiling (Fig. 6).
Motor to Receiver & Receiver to house supply wires (Fig. 6A).
1. Connect the hanger ball/downrod assembly ground wire, mounting bracket
ground wire and receiver ground wire to the ground wire in outlet box.
WARNING: Failure to connect ground wires could result in poor fan control
functionality.
2. Connect the red wire from the fan to the red wire marked “TO MOTOR” from
the receiver.
3. Connect the grey wire from the fan to the grey wire marked “TO MOTOR” from
the receiver.
4. Connect the yellow wire from the fan to the yellow wire marked “TO MOTOR”
from the receiver.
5. Connect the white wire from the fan to the white wire marked “FOR LIGHT”
from the receiver.
6. Connect the blue wire from the fan to the blue wire marked “FOR LIGHT”
from the receiver.
7. Connect the black (hot) wire from the ceiling to the black wire marked “AC
in L” from the receiver.
8. Connect the white (neutral) wire from the ceiling to the white wire marked
“AC in N” from the receiver.
18 Lucid Instructions
FR-W2304-62L
6
1. Mounting Bracket 2. Receiver
1 2
6A
Black(Hot) can be RED from Switch leg
Black(Line in H)
Receiver
Outlet Box
GREEN(Ground) WHITE(Neutral) WHITE(Line in N)
GREEN(GND Must Use) GREEN(Hanger Bracket Ground)
Hanger Bracket
GREY(to Motor) YELLOW(to Motor)
RED(to Motor)
RED(to Motor) YELLOW(to Motor)
GREY(to Motor)
BLUE (to Light) WHITE(to Light) GREEN(Hanger Bracket Ground)
WHITE(Neutral) BLUE (for Light)
Safety Cable
Hanger Ball & Downrod
Follow the steps above to connect the fan to your household wiring. Use the plastic wire nuts with your fan. Secure the plastic wire nuts with electrical tape. Make sure there are no loose strands or connections.
FR-W2304-62L
Lucid Instructions 19
7. Installing the Optional Wall Control
NOTE: Bluetooth Wall Control Optional Accessory not included. A Bluetooth Wall
Control can be purchased separately.
1. Connect the green wire marked “GROUND” from the wall control to the copper
wire from the wall outlet box that feeds back to the circuit breaker
important for proper fan function (Fig. 7).
2. Connect the black wire marked “LINE IN” from the wall control to the black
LINE VOLTAGE wire from the wall outlet box that feeds back to the circuit
breaker (Fig. 7).
3. Connect the red wire from the wall control to the black wire from the wall
outlet box that feeds up to the fan (Fig. 7).
4. Connect the white wire from the wall control to the white (neutral) wire
from the wall outlet box (Fig. 7).
5. Carefully tuck the wire connections inside the outlet box. Secure the wall
control with the two (2) wall control screws provided (Fig. 7A).
6. Attach the wall mounting plate over the wall switch and secure with the
two (2) wall mounting plate screws provided (Fig. 7A).
7. Fasten the wall plate to the wall mounting plate (Fig. 7A).
7
to Fan
House Wires
Wall Switch Wires
(Hot)
(Hot In)
(Neutral) (Copper/Ground)
(Neutral) (Ground)
Fan Switch leg
20 Lucid Instructions
From Breaker
- Home Wiring may vary
(Hot out to Fan) FR-W2304-62L
7A
1
2
3
1. Wall Outlet 2. Wall Control 3. Wall Mounting Plate 4. Mounting Plate Screws 5. Wallplate
4
5
Multi-location wiring
Individually pair each of the wall controls with the fan receiver using the
pairing instruction. See page 27.
If Applicable
Line/Hot
Red
WWaalllcl oCnotnrtorlolel r11
WWaalllcl oCnotnrtorlolel r22
WWaallclloCnotnrotrlloelr33
Green (Green or Bare)
FAN
Neutral/White
FR-W2304-62L
Lucid Instructions 21
8. Finishing the Installation
1. Secure all wire connections with supplied wire ties to assist in canopy
installation.
2. Tuck connections neatly into ceiling outlet box.
3. Slide the canopy up to hanger bracket and place the key hole on the canopy
over the screw on the hanger bracket. Turn canopy until it locks in place at
the narrow section of the key holes (Fig. 8).
4. Align the circular hole on canopy with the remaining hole on the hanger
bracket. Secure by tightening the one screw previously loosened and the one
previously removed. (Fig. 8)
5. Adjust the canopy screws as necessary until the canopy and canopy cover
are snug. (Fig. 8A)
WARNING: Make sure tab at bottom of hanger bracket is properly seated in
groove of hanger ball before attaching canopy to bracket. Failure to properly
seat tab in groove could cause damage to electrical wiring.
22 Lucid Instructions
FR-W2304-62L
8
8A
FR-W2304-62L
Lucid Instructions 23
9. Installing the LED Luminaire Module
WARNING: Before starting installation, disconnect the power by turning off the
circuit breaker or removing the fuse at fuse box.
1. Locate the LED screw bag. Use Hardware F.
2. Raise and hold the LED luminaire module close to the mounting plate and
proceed to secure the wire connections. Connect the white wire connectors from
the luminaire module to the white wire of the fan. Connect the blue wire from
the fan to the blue wire from the LED module (Fig. 9/9A).
3. Tuck connections neatly into mounting plate. Place the luminaire module
against the adapter plate and secure with the 3 screws from the LED screw bag
(Fig. 9B).
4. Raise Light Shade up against the luminaire module, and secure it to fan by
turning shade clockwise until snug. Do not overtighten (Fig. 9C)
24 Lucid Instructions
FR-W2304-62L
9
9A
9B
FR-W2304-62L
4
Light shade
9C
Lucid Instructions 25
10. Controlling the Fan
Your fan was delivered to you with the included control already paired to your
fan. A: Light On/Off, Bright/Dim B: Fan On/Off, Speed Up/Down C: Season
(Summer/Winter) Air-Gap Switch: Pull tab to power off in case of emergency.
Not necessary for normal fan operation (only included with wall control).
NOTE: Your fan features 6 speeds. An audible tone will indicate when the speed
is increased or decreased. When the fan has reached the minimum/maximum speed
level the fan will beep twice.
Controlling One or Multiple Fans with Remote or Wall Controls The Bluetooth
Remote or Wall Control is capable of controlling an unlimited number of fans
within line of site. See (Fig. 10C) for Pairing.
NOTE: Pairing must be completed within three (3) minutes of powering the fan.
Synchronizing Control Across Multiple Fans If you are controlling multiple
fans with one controller, fans/lights may be synced by referring to Fig. 10B
and instructions on the next page.
26 Lucid Instructions
FR-W2304-62L
10
A A
B
B
C
Air-Gap
C
Switch*
Wall Control
- Air-Gap Switch only included with wall control
Remote Control
10B
10A
Summer Mode
(Counter-Clockwise)
Winter Mode
(Clockwise)
Fan On/Off
Press and hold button for 4 seconds.
Light On/Off
Press and hold button for 4 seconds.
Fan Direction
Press and hold button for 4 seconds.
Fan On/Off: Press and hold button for 4 seconds. The LED on the remote will flash green and all connected fans will beep to indicate the message has been received. All fans will turn off. This will bring all fans controlled by the remote into sync.
Light On/Off: Press and hold button for 4 seconds. The LED on the remote will
flash
green and all connected fans will beep to indicate the message has been
received. All
lights will turn off. This will bring all fans controlled by the remote into
sync.
Fan Direction: Press and hold button for 4 seconds. The LED on the remote will
flash green and all connected fans will beep to indicate the message has been
received. All fans will be set to summer mode (CCW rotation). This will bring all fans
controlled by the remote into sync.
FR-W2304-62L
Lucid Instructions 27
11. Reset
If advised by fan support, you can reset your fan to factory settings by
referring to (Fig. 11A) or (Fig. 11B). NOTE: If you change your Wi-Fi settings
(SSID or Security Passphrase) you will require a Wi-Fi reset. Refer to Fig. 11
and then use the Modern Forms app to connect your fan to the new network.
12. Breeze Mode
Breeze Mode mimics the natural ebb and flow of winds in nature by varying the
fan speed.
NOTE: Breeze Mode always rotates your fan in the Summer direction. 1. To start
Breeze Mode, press and for 4 seconds. The LED will
blink green and the fan will beep. 2. To exit Breeze Mode and return to
standard fan mode, press
and for 4 seconds. The led will blink green and the fan will beep. Your fan
will return to the direction and speed it was set to prior to entering Breeze
Mode.
13. Application
In addition to the included remote control, you can control your fan with a
wall control (sold separately) or through the Modern Forms app. To use the
Modern Forms app, download it for free from the App Store or Google Play.
1. Open the app to create your account. You can also log in using your
Facebook or Google account.
2. To set up a Wi-Fi connection you will need the SSID and Wi-Fi password for
the network you wish to connect to.
3. You will receive a prompt to name your fan device and upload an optional
picture of it if you choose.
4. The Modern Forms app allows you to perform normal fan functions, as well
as create schedules, set sleep timers, invite other users, create groups, and
use smart features such as Adaptive Learning. Integrate with smart home
systems you already own including Amazon Alexa, Google Assistant, Samsung
SmartThings, Control 4, and more.
28 Lucid Instructions
FR-W2304-62L
10C
11
Pairing
Unpairing
Press and hold buttons To purge, press and hold
for 10-15 seconds
buttons for 4 seconds
11A
Fan Wi-Fi Reset
Press and hold the and
for 10 seconds until
LED blinks green and receiver emits 2 long beeps
11B
Factory Reset
Press and hold buttons for 10 seconds until the fan emits 3 beeps indicating
the reset
Receiver Factory Reset
Press the reset button on the receiver until the receiver emits 3 beeps
indicating the reset
FR-W2304-62L
10% LV2
For support videos on installation and smart home device intergration
Lucid Instructions 29
14. Accessories
personalize your experience
Bluetooth Wall Control
Dims light to 1% | ON/OFF 6 fan speeds | Sold separately F-WCBT-WT White
Bluetooth Remote Control
Dims light to 1% | ON/OFF 6 fan speeds F-RCBT-WT White
30 Lucid Instructions
FR-W2304-62L
Sloped Ceiling Kit
Designed to accommodate buildings with steeper sloped ceilings up to 45° or
12/12 pitch XF-SCK
Coupler
Connects two downrods XF-I
Downrod
XF-12 – 12″ Downrod | XF-18 – 18″ Downrod XF-24 – 24″ Downrod | XF-36 – 36″
Downrod XF-48 – 48″ Downrod | XF-60 – 60″ Downrod XF-72 – 72″ Downrod
FR-W2304-62L
Lucid Instructions 31
15. Troubleshooting
My Fan Will Not Start 1. Check main and branch circuit fuses or circuit
breakers. 2. Check line wire connections to fan and switch wire connections in
the switch housings. CAUTION: Make sure the main power is turned off!
My Fan is Noisy
1. Allow for 24-hour break-in period. Most noises associated with a new fan
will go away during this time period.
2. Check to make sure the screws which attached to the blades (and blade arms
when applicable) are tight.
3. Check to make sure all screws in motor housing are snug.
4. Make sure light cover is tightened and/or glass is snug.
5. Tighten the hanger bracket screws and make sure the outlet box is secured.
6. Your wire connectors may be rattling against the fan’s canopy.
7. Make sure you have a cUL/UL approved outlet box and it is installed
correctly.
My Fan is Wobbling
1. Tighten the setscrews in the downrod.
2. Make sure your hanger ball assembly is locked into place in the hanger
bracket.
3. Tighten the hanger bracket screws to the outlet box.
4. Make sure the fan blades are properly aligned and securely fastened to the
motor housing assembly/blade arms.
5. Make sure the gaps between the blades are evenly distributed or make sure
you are using an approved cUL/UL listed outlet box and it is installed
correctly.
32 Lucid Instructions
FR-W2304-62L
My Fan is not producing Enough Air Movement If possible, please consider using
a longer than included downrod.
My remote or wall control is not controlling my fan Verify that the fan is
receiving power by power cycling the fan. To do this: 1. Cut power to the fan
via standard On/Off wall switch, or the
breaker if standard wall switch is not applicable. 2. Wait at least 10
seconds, and then restore power. 3. The fan will power on in Pairing mode for
3 minutes. 4. Press and hold and buttons on wall control for
10-15 seconds. 5. When the LED indicator remains solid green, and three (2)
audible beeps are heard, the pairing process is complete.
I don’t see my fan’s WiFi (ModernFormFan_XXXXXX) in my phone’s list of
available WiFi networks. 1. If your fan had been previously paired the Wi-Fi
radio will be off. 2. To turn on Wi-Fi, press and hold fan speed up and fan
speed down
buttons on your remote control or wall control for 6 seconds. 3. The fan will
beep and you will see its Wi-Fi network available for
connection.
My home Wi-Fi network is not showing up in the app’s list during setup. 1.
Your fan supports connection with 2.4GHz 802.11b/g/n networks.
Confirm your network is compatible by checking your router settings or contact
your router manufacturer. 2. Make sure your network’s SSID is not hidden. 3.
Your fan does not support 5 GHz network connectivity. connection.
FR-W2304-62L
Lucid Instructions 33
15. Troubleshooting cont.
My Fan failed to join the Wi-Fi network 1. Make sure you entered the correct
Wi-Fi password and your
mobile device is connected to the same network you attempted to connect the
fan. 2. Make sure you are within the router manufacturer’s specified range. If
all of these steps have failed – please power cycle your fan and router and
retry.
What is power cycling and how do I power cycle my fan?
Power cycling is the act of temporaily removing the power source for your fan.
If the fan is powered through a wall switch, turn the switch off for 10
seconds and back on. Alternately, you can use the circuit breaker the fan is
connected to by toggling it off for 10 seconds and back on. If your fan is
wired through a Modern Forms wall control (P/N: F-WCBT-WT) pull the Air-Gap
Switch on your wall control, wait 10 seconds, and re-insert.
What is Adaptive Learning?
Adaptive learning is an exclusive feature that allows your fan to learn your
daily/weekly habits and automatically recommend scheduled activity through the
Modern Forms app. This feature can be toggled on or off.
What is Breeze Mode?
Breeze Mode mimics the natural ebb and flow of winds in nature by fluctuating
your fan’s speed.
34 Lucid Instructions
FR-W2304-62L
What is Pairing?
Pairing is the process of connecting your Modern Forms remote or wall control
to your fan. Your fan comes pre-paired to your included remote control.
However, if you want additional controls for your fan or if you’re replacing a
control, refer to the pairing and unpairing section of the instructions.
What is a Factory Reset?
Factory Reset is a restore of the fans original settings. This can be achieved
from the control or by pressing and holding the small button on the receiver
until you hear three audible beeps or by holding down the fan toggle, light
toggle, and season toggle buttons on your paired remote or wall control for 10
seconds.
NOTE: You will need to re-pair your remote or wall controls to the fan
following a factory reset. A factory reset will also disconnect the fan from
your home Wi-Fi network and will require you to add the fan using the Modern
Forms Smart Fans app.
Please refer to the FAQ section of our app for further guidance. For all other
questions, please contact our dedicated Fan Support specialists. Contact
information can be found at the front of the instructions.
FR-W2304-62L
Lucid Instructions 35
Certificate of Warranty
Congratulations on your new purchase.
Your new Modern Forms Smart Fan is engineered to make life easier every day.
Modern Forms creates future-forward fans and luminaires that provide energy
savings and outstanding efficiency. Our dedication to doing things the right
way goes beyond our love for amazing products. Modern Forms Smart FansTM
warrants any of its outdoor rated ceiling fan products that they are to be
free from defects in material and workmanship for a period of one (1) year
from the date of purchase; outdoor painted finishes are warranted for two (2)
years; LED light modules and electronic components are warranted for five (5)
years; DC motors and stainless steel finishes are warranted for lifetime under
normal use to the first non-dealer purchaser.
Although Modern Forms uses the best available materials and does extensive
testing for finish endurance, some fading or chalking may occur and is
considered normal. For coastal locations, some corrosion and/or deterioration
is considered “normal wear” in this environment. Therefore, any finish claim
due to coastal environment conditions is not applicable to our warranty. If a
product is defective, all efforts will be made to correct the problem in the
field. If the problem cannot be resolved, an RGA number will be issued. Modern
Forms obligation is expressly limited to repair or replacement, without
charge, at the Modern Forms factory after prior written return authorization
has been granted. Modern Forms obligation under this warranty shall not extend
beyond the distributor’s initial purchase price of the product and accordingly
any consequential damages or labor costs arising out of a defect are expressly
excluded. This warranty shall not apply to products that have been altered,
improperly installed, mishandled or misused. Notice of a defect in writing
must be received by Modern Forms within five (5) years from the date of
purchase (or according period of time as outlined by material). Excluded from
warranty are any 3rd party component which carries its own manufacturer’s
warranty. Note: Modern Forms product warranty applies only to purchases from
authorized Modern Forms distributors. THERE ARE NO WARRANTIES WHICH EXTEND
BEYOND THE DESCRIPTION ON THE FACE HEREOF INCLUDING WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The Bluetooth ® word
mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any
use of such marks by Wangs Alliance Corporation is under license. Other
trademarks and trade names are those of their respective owners.
Felicidades por tu nueva compra.
Su nuevo ventilador moderno de formas modernas está diseñado para facilitarle
la vida cada día. Modern Forms crea ventiladores y luminarias para el futuro
que proporcionan ahorros de energía y eficiencia excepcional. Nuestra
dedicación a hacer las cosas de la manera correcta va más allá de nuestro amor
por los productos asombrosos. Modern Forms garantiza a cualquiera de sus
productos para ventiladores de techo con clasificación exterior que estén
libres de defectos en materiales y mano de obra por un período de un (1) año
desde el fecha de compra; Los módulos de luz LED están garantizados por cinco
(5) años; Los motores de CC y los acabados de acero inoxidable están
garantizados de por vida bajo el uso normal para el primer comprador no
distribuidor.
Aunque Modern Forms utiliza los mejores materiales disponibles y realiza
pruebas exhaustivas para la resistencia del acabado, puede producirse cierto
desvanecimiento o parloteo y se considera normal. Para las ubicaciones
costeras, cierta corrosión y / o deterioro se considera “desgaste normal” en
este entorno. Por lo tanto, cualquier reclamación de acabado debido a las
condiciones del entorno costero no se aplica a nuestra garantía. Si un
producto es defectuoso, se harán todos los esfuerzos para corregirlo. El
problema en el campo. Si el problema no se puede resolver, se emitirá un
número RGA. La obligación de Modern Forms se limita expresamente a la
reparación o el reemplazo, sin cargo, en la fábrica de Modern Forms después de
que se haya otorgado una autorización previa por escrito.La obligación de
Formas modernas bajo esta garantía no se extenderá más allá del precio de
compra inicial del producto por
36 Lucid Instructions
FR-W2304-62L
parte del distribuidor y, en consecuencia, cualquier daño consecuencial o
costo de mano de obra que surja de un defecto se excluye expresamente. Esta
garantía no se aplicará a los productos que hayan sido alterados, instalados
incorrectamente, mal manejados o mal utilizados. La notificación de un defecto
por escrito debe ser recibida por Modern Forms dentro de los cinco (5) años a
partir de la fecha de compra (o según el período de tiempo indicado en el
material). Quedan excluidos de la garantía todos los componentes de terceros
que tengan la garantía de su propio fabricante. Nota: la garantía del producto
Modern Forms se aplica solo a las compras de los distribuidores autorizados de
Modern Forms. NO HAY GARANTÍAS QUE SE EXTIENDAN MÁS ALLÁ DE LA DESCRIPCIÓN DE
SU CARACTERÍSTICA, INCLUIDAS LAS GARANTÍAS DE COMERCIABILIDAD Y ADECUACIÓN
PARA UN PROPÓSITO PARTICULAR. La marca denominativa y los logotipos Bluetooth
® son marcas registradas propiedad de Bluetooth SIG, Inc. y cualquier uso de
dichas marcas por parte de Wangs Alliance Corporation se realiza bajo
licencia. Otras marcas comerciales y nombres comerciales pertenecen a sus
respectivos propietarios.
Félicitations pour votre nouvel achat.
Votre nouveau ventilateur intelligent Modern Forms est conçu pour vous
simplifier la vie au quotidien. Modern Forms crée des ventilateurs et des
luminaires d’avant-garde qui permettent des économies d’énergie et une
efficacité exceptionnelle. Notre engagement à bien faire les choses va au-delà
de notre amour pour les produits étonnants. Modern Forms garantit à tous ses
produits pour ventilateurs de plafond pour extérieur qu’ils ne doivent
présenter aucun défaut de matériau ou de fabrication pendant un (1) an date
d’achat; Les modules d’éclairage à LED sont garantis pendant cinq (5) ans; Les
moteurs à courant continu et les finis en acier inoxydable sont garantis à vie
dans les conditions normales d’utilisation par le premier acheteur non
revendeur.
Bien que Modern Forms utilise les meilleurs matériaux disponibles et effectue
des tests approfondis pour l’endurance de la finition, des décolorations ou
des craies peuvent se produire et sont considérés comme normaux. Pour les
zones côtières, une certaine corrosion et / ou détérioration est considérée
comme une «usure normale» dans cet environnement. Par conséquent, toute
réclamation liée à la finition en raison des conditions de l’environnement
côtier ne s’applique pas à notre garantie. Si un produit est défectueux, tous
les efforts seront déployés pour y remédier. Le problème sur le terrain. Si le
problème ne peut pas être résolu, un numéro RGA sera attribué. L’obligation de
Modern Forms est expressément limitée à la réparation ou au remplacement, sans
frais, dans l’usine de Modern Forms après autorisation écrite préalable du
retour. L’obligation de Modern Forms au titre de cette garantie ne s’étendra
pas au-delà du prix d’achat initial du produit par le distributeur. En
conséquence, tout dommage indirect ou tout coût de main-d’oeuvre résultant
d’un défaut est expressément exclu. Cette garantie ne s’applique pas aux
produits modifiés, mal installés, manipulés ou utilisés de manière
inappropriée. Modern Forms doit recevoir un avis écrit du défaut dans un délai
de cinq (5) ans à compter de la date d’achat (ou selon la période précisée
dans les informations fournies). Sont exclus de la garantie tout composant
tiers bénéficiant de la garantie du fabricant. Remarque: la garantie des
produits Modern Forms ne s’applique qu’aux achats auprès des distributeurs
agréés Modern Forms. IL N’Y A AUCUNE GARANTIE QUI ALLAIT AU-DELÀ DE LA
DESCRIPTION FACE AU PRESENT, INCLUANT LES GARANTIES DE QUALITÉ MARCHANDE ET
D’ADÉQUATION À UN USAGE PARTICULIER. La marque et les logos Bluetooth ® sont
des marques déposées appartenant à Bluetooth SIG, Inc. et toute utilisation de
ces marques par Wangs Alliance Corporation est sous licence. Les autres
marques et noms commerciaux appartiennent à leurs propriétaires respectifs.
FR-W2304-62L
Lucid Instructions 37
38 Lucid Instructions
FR-W2304-62L
FR-W2304-62L
Lucid Instructions 39
FR-W2304-62L modernforms.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>