INSTALLATION INSTRUCTIONS
LR100Y6K-EM
YALE ELECTRIC LATCH RETRACTION DEVICE KIT
MODELS: 6100ED RIM
Retrofit Installation Note: 42″ or 48″ exit devices that have been modified to
fit a 36″ or smaller opening may not have the required space to fit the
standard E. L. R. assembly. Always verify the distance from the end of the
touchpad to the end rail and, if necessary, consult with the factory for
appropriate selection.
Remove the Device End Cap and Cover from exit device. Replace the existing
Cover End Cap with the provided replacement End Cap packaged with ELR kit.
If present, remove mechanical dogging assembly. Use the provided Template to
add required mounting hole. Drill clearance as indicated for a 8-32 screw .
Countersink the opposite side of rail extrusion.
Slide the ELR assembly into the
rail extrusion over the Dogging Arm within the device. Loosen the Catch Screw
if required to allow for the ELR to be inserted over Dogging Arm. Fasten the
ELR assembly to the rail extrusion of device as illustrated below using the
provided mounting screws from ELR kit.Once kit is
secured to the device depress the Push Pad and tighten the Catch Screw on ELR
kit to secure the Locking Pin in place. Release Push pad and energize the ELR
to verify operation. Re-install Cover with new Endcap and Device End Cap.
NOTE Retro-Fitting Vertical Rod Devices:
Before retro-fitting an electric latch assembly into a vertical device, the
following must be done to ensure proper alignment. Disconnect the vertical
rods from the device head. Once the ELR is properly installed energize it so
that the push pad is dogged down, by doing so it will allow for proper
alignment for the vertical rods. Finally reconnect the vertical rods to the
device and make the proper adjustments.