SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the product. Failure to do so could lead to electric shock, fire or other injuries that could be hazardous or even fatal.

  • Be sure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker.
  • Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
  • This product must be installed in accordance with local, state, and national electrical codes.
  • Installation work shall be completed by a licensed installer that is familiar with the construction and operations of the product.

CAUTION:

  • Building supply input: 120-277 Vac 60Hz
  • Minimum 90 degrees Celcius supply conductors.
  • This product can only be dimmed with standard 0-10V low voltage dimming systems

NOTICE:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

WARNING

  • Risk of fire or electric shock. LED Kit installations require knowledge of luminary electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Disconnect power at fuse or circuit breaker before installing or servicing.
  • No user-serviceable parts inside. To avoid electrical shock, do not disassemble the product.
    • This product is not intended for use in emergency light fixtures or exit signs. Not for use where exposed directly to the weather or water.
    • This product contains a chemical known to the state of California to cause cancer, birth defects or other reproductive harm.

PACKAGE CONTENTS

Before beginning assembly of the product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product. Estimated Assembly Time: 40 minutes

INSTALLATION INSTRUCTIONS

  • Ceiling Mount Installations
  • Multiple Fixture Installations
  • Suspension, Surface, Recessed, and Wall Mounting installations

GENERAL INSTALLATION INSTRUCTIONSENERGETIC LIGHTING E1LAL Series CCT
Selectable LED Linear Architectural Lighting Fixture FIG
1

  1. Undo screws to remove the end cap from the female side of the linear fixture
  2. Remove the end cap
  3. Undo the screw of the knockout and remove the desired size knockout.

Save end caps and screws for later use.

ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural
Lighting Fixture FIG 2

Lift Linear fixture up to already installed suspension cables. Snap fixture mounting clips onto the linear fixture.
Note: the open female side in the illustration is to be lined up to the suspension cable that has the power feed for the fixture.

  • Feed the power supply cable through the wire brushing, then through the knockout plate after you have already knocked a hole out for cable and wire brushing.ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural Lighting Fixture FIG 3
    • Insert the five lead wires into the female quick connector.( Use the pre-connected wires as a guide to match up the color wires.
  • Once wire connections are complete secure endcaps and knockout plates with screws for the sealed fixture.ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural Lighting Fixture FIG 4
  • Adjust the suspension cable along the fixture itself and screw it down for the desired location on the fixture.ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural Lighting Fixture FIG 5
    • Optional but not required to zip tie both aircraft cable and power feed together.

INSTALLATION FOR MULTIPLE FIXTURESENERGETIC LIGHTING E1LAL Series CCT
Selectable LED Linear Architectural Lighting Fixture FIG
6

  1. Undo screws to remove the end cap from the female side of the linear fixture
  2. Remove the end cap
  3. Undo the screw of the knockout and remove the desired size knockout.

Save end caps and screws for later use.

  • Feed the power supply cable through the wire brushing, then through the knockout plate after you have already knocked a hole out for cable and wire brushing.
  • Insert the five lead wires into the female quick connector.( Use the pre-connected wires as a guide to match up the color wires.

ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural
Lighting Fixture FIG 7

Secure the bracket lever & loop to the fixture to the female side of the fixture and the hook to the male side of the fixture.
After securing the latching system assembly, loop the latch arm over the hook and press down flat until both ends are secured for a seamless fit.
Note : When linking more than three fixtures or L,T, X, Y, and V connectors the corresponding Male and Female sides correspond with the Latching hook and lever system.
Wire connectors are found at both ends under the knockout plates, note that fixture sections must be oriented so that male and female connectors are adjacent to each other at the junction.

Once secured place down knockout plates and secure them with the screw.
Note : When linking more than three fixtures or L, T, X, Y, and V connectors the corresponding Male and Female sides correspond with the Latching hook and lever system.

INSTALLATION FOR CANOPY SUSPENDED MOUNTINGENERGETIC LIGHTING E1LAL Series
CCT Selectable LED Linear Architectural Lighting Fixture FIG
9

  1. Secure (A) mounting bracket to the junction box with two mounting screws.

  2. Screw in a stud in the (A) Mounting bracket.

  3. Feed (E) 5 wire cable through (B1) cord grip on (B) canopy, connect supply wires to (E) 5 wire cable matching the color of the wires. Secure all connections with wire nuts.

  4. Lock (E) 5 wire cables in place with cord grip.
    Carefully tuck all connected wires inside of junction box, bring canopy up and over (A1) mounting bolt. Secure (D1) threaded nipple onto (A1) mounting bolt, then screw on (D2) lock collar up against (B) canopy.

  5. Screw on (G) fixture clip onto (F) aircraft cable Lock.

  6. Adjust (C) aircraft cable length by pushing down on (F) cable lock’s release tab spring-loaded mechanism and then pull the bare end of (C) aircraft cable through (F) cable lock’s exit hole.

Canopy with Power Feed Kit:ENERGETIC LIGHTING E1LAL Series CCT Selectable
LED Linear Architectural Lighting Fixture FIG 11

  • Canopy with Power Feed Kit:
  • A Mounting Bracket
  • B Canopy
  • C Aircraft Cable
  • D1 Threaded Nipple
  • D2 Lock Collar
  • F Cable Lock
  • G Fixture Clip

Canopy Installation IndexENERGETIC LIGHTING E1LAL Series CCT Selectable
LED Linear Architectural Lighting Fixture FIG 10

INSTALLATION FOR DIRECT CEILING MOUNTING KIT

Direct Ceiling Kit:

  • D1 Lock Collar
  • D2 Threaded Nipple
  • C Aircraft Cable
  • F Cable Gripper
  • G Fixture Clip
  • H1 Toggle Gripper
  • H2 Bolt

ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural
Lighting Fixture FIG 13

  1. Follow the toggle installation of figure 1. to secure the ceiling.
  2. Screw (G) onto the Cable gripper (F) Figure 2
  3. Adjust aircraft cable (C) by pushing down on the cable gripper’s spring-loaded mechanism (F) you can bring down the fixture to the desired length. Pulling on the bare end of the Aircraft cable (C) lifts the fixture clip (G) to be in a higher position.
INSTALLATION FOR SURFACE CEILING MOUNTING KIT

Surface Ceiling Kit:ENERGETIC LIGHTING E1LAL Series CCT Selectable LED
Linear Architectural Lighting Fixture FIG 14

  • A Junction Plate
  • B1 Toggle Gripper
  • B2 Bolt
  • C1 Lock Collar
  • C2 Standoff
  1. Follow the toggle installation of figure 1. to secure the to ceiling.

  2. Undo screws to remove the end cap from the female side of the linear fixture

  3. Remove the end cap

  4. Undo the screw of the knockout and remove the desired size knockout.

  5. Knock out a metal place for wire brushing into knockout plate
    Save end caps and screws for later use.

  6. Connect the power feed to the junction box for stand-alone fixtures you can remove the quick connectors, and for two or more fixtures continue to plug in the wires to the quick connectors.

  7. Cover the junction hole with the junction plate provided.ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural Lighting Fixture FIG 17

  8. Lift the fixture to the ceiling and leave the female side open for the power feed to slide through the knockout plate, connect wires to their counterpart or into the quick connectors. Tuck away any wires or power feed and install the end cap.ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural Lighting Fixture FIG 18

  9. Once wires are tucked away.

  10. Remove the lens and find the standoff screw holes for the standoff to be screwed directly through the LED Panel. Once properly screwed and secured. Carefully reinstall the lens back to the fixture.

INSTALLATION FOR RECESSED MOUNTING KIT

Surface Ceiling Kit:

  • A Recess mounting bracket
  • B1 Mounting screw
  • B2 Wall anchors
  • C recessed bracket screws

ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural
Lighting Fixture FIG 20

  1. Undo screws to remove the end cap from the female side of the linear fixture

  2. Remove the end cap

  3. Undo the screw of the knockout and remove the desired size knockout.
    Save end caps and screws for later use.

  4. Feed the power supply cable through the wire brushing, then through the knockout plate after you have already knocked a hole out for cable and wire brushing.

  5. Insert the five lead wires into the female quick connector.(Use the pre-connected wires as a guide to match up the color wires.)
    Note : See page 5 if installing multiple lighting fixtures.

  6. Screw in wall anchors (B2) and mounting screws (B) then place (A) in the fixture through the standoff knockout near the knockout plate. Then removed lens and screw in recessed bracket (C)

INSTALLATION FOR WALL MOUNTING KITENERGETIC LIGHTING E1LAL Series CCT
Selectable LED Linear Architectural Lighting Fixture FIG
21

  1. Undo screws to remove end cap from the female side of the linear fixture

  2. Remove the end cap

  3. Undo the screw of the knockout and remove the desired size knockout.
    Save end caps and screws for later use.

  4. Feed the power supply cable through the wire brushing, then through the knockout plate after you have already knocked a hole out for cable and wire brushing.

  5. Insert the five lead wires into the female quick connector.(Use the pre-connected wires as a guide to match up the color wires.)

  6. Screw in wall anchors and then place wall bracket over and use mounting screws to fully secure the bracket to the wall.

  7. Then use bracket screws to secure the fixture clip to the wall bracket.ENERGETIC LIGHTING E1LAL Series CCT Selectable LED Linear Architectural Lighting Fixture FIG 22

  8. Two options for power feed connections. First, through the knockout on the top. Secondly is to drill a hole 3” inched from the end of the female side. Using the wall surface kit.

  9. Either way, lift the fixture up to the clips and secure the clips and fixture together.

  CARE AND MAINTENANCE

Clean with a mild, non-abrasive glass cleaner and soft cloth. Do NOT use solvents or cleaners containing abrasive agents. When cleaning the fixture, make sure the power is turned off, and any liquid spray should be applied to the cleaning cloth and not sprayed directly onto the fixture itself.

TROUBLESHOOTING

WARRANTY

This fixture is warranted to perform free from defects for five(5) years. If it fails to do so, you may return it with proof of purchase to 13445 12th St., Chino, CA 91710 for replacement.

www.energeticlighting.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Energetic Lighting User Manuals

Related Manuals