SLOAN 0816452 G2/Ecos Single Flush Instruction Manual
- June 9, 2024
- SLOAN
Table of Contents
- PRIOR TO INSTALLATION
- TOOLS REQUIRED FOR INSTALLATION
- VALVE ROUGH-IN
- ALTERNATIVE WATER CLOSET INSTALLATION
- FOR COMPLETE VALVE INSTALLATION START HERE. FOR RESS RETROFIT
- INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO SUPPLY PIPE
- FLUSH OUT SUPPLY LINE
- INSTALL VACUUM BREAKER FLUSH CONNECTION
- INSTALL FLUSHOMETER
- WHEN RETROFITTING AN EXISTING VALVE, START HERE. REMOVE COMPONENTS FROM
- G2/ECOS FLUSH VOLUME
- ASSEMBLE FLEX TUBE DIAPHRAGM TO G2/ECOS ASSEMBLY
- TIGHTEN LOCKING RING
- REMOVE TAB TO ACTIVATE SENSOR MODULE
- TEST SENSOR OPERATION
- ADJUST CONTROL STOP AND INSTALL VANDAL RESISTANT STOP CAP
- OPERATION
- RANGE ADJUSTMENT (ADJUST ONLY IF NECESSARY)
- BATTERY REPLACEMENT
- CARE AND CLEANING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SLOAN 0816452 G2/Ecos Single Flush Instruction Manual
PRIOR TO INSTALLATION
Prior to installing the Optima Plus flushometer, install the items listed below as illustrated in the Rough-in Diagram. (New installations only.)
- Closet or Urinal fixture
- Drain line
- Water supply line
Important:
- ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.
- WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
- WHEN INSTALLING A FLUSHOMETER, IT IS IMPORTANT THAT THE FLUSH MODEL MATCHES THE REQUIREMENTS OF THE PLUMBING FIXTURE.
- FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
The Optima Plus is designed to operate with 15 to 80 PSI (104 to 552 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for pressure requirements. Most Low Consumption water closets (1.6 gallon/6 liter) require a minimum flowing pressure of 25 psi (172 kPa).
TOOLS REQUIRED FOR INSTALLATION
- Slotted screwdriver to adjust control stop.
- Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench for couplings.
- Strap wrench (supplied) to install Optima Plus to valve body.
- 7/64” hex wrench (supplied) to secure Optima Plus cover to base plate.
VALVE ROUGH-IN
Typical Water Closet Installation
Model 8110/8111 Reference for RESS-C Retrofit
High Rough-in Water Closet Installation
Models 8113, 8115 & 8116
Typical Urinal Installation
Models 8180 & 8186 Reference for RESS-U Retrofit
Model 8115 & 8116 valves are designed for installations where the water supply is roughed-in 24” – 27” (610mm – 686 mm) above the top of the water closet. For new installations, Sloan strongly recommends the use of our Model 8111 which has a shorter installation height
Model | “X” | “Y” |
---|---|---|
8113 | 16” (406 mm) | 21” (533 mm) |
8115 | 24” (610 mm) | 29” (737 mm) |
8116 | 27” (686 mm) | 32” (813 mm |
Squat Toilet Water Closet Installation Model 8137
ALTERNATIVE WATER CLOSET INSTALLATION
When installing the Sloan G2 Electronic Flushometer in an ADA compliant stall:
Per ADA Guidelines (section 604.9.4) it is recommended that the grab bars be
split or shifted to the wide side of the stall. For alternative installations,
lower water supply rough-in to 10” (254 mm), or use the H-1018-A 1-1/2” offset
adapter (not supplied) to lower the overall height. The Sloan H-1018-A 1” NPT
x 1-1/2” offset adapter kit (sold separately) is designed to lower a G2
Flushometer 1-1/2” when the space above the top of the Flushometer conflicts
with grab bar clearance. Mount the grab bar at the 36” (914 mm) maximum
allowed height (top of grab bar at 36”)
FOR COMPLETE VALVE INSTALLATION START HERE. FOR RESS RETROFIT
INSTALLATION, START AT STEP 6. INSTALL OPTIONAL SWEAT SOLDER ADAPTER (ONLY IF YOUR SUPPLY PIPE DOES NOT HAVE A MALE THREAD)
- A Measure from finished wall to C/L of Fixture Spud. Cut pipe 1¼” (32 mm) shorter than this measurement. Chamfer O.D. and I.D. of water supply pipe.
- B Slide Threaded Adapter fully onto pipe.
- C Sweat solder the Adapter to pipe
IMPORTANT
With the exception of Control Stop Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling!
IMPORTANT
Protect the chrome or special finish of Sloan Flushometers DO NOT USE toothed tools to install or service these valves. Use a Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed spud wrench to secure all couplings. Also see “Care and Cleaning” section of this manual.
IMPORTANT
LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED ON FIXTURES OR FLUSHOMETERS
IMPORTANT
This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.
INSTALL COVER TUBE, WALL FLANGE AND CONTROL STOP TO SUPPLY PIPE
-
A Measure from finished wall to first thread of Adapter or threaded supply pipe (dimension “X”). Cut Cover Tube to this length.
-
B Slide Cover Tube over pipe. Slide Wall Flange over Cover Tube until against wall.
-
C Thread Control Stop onto pipe. Tighten with a wrench.
-
D Tighten Set Screw with a 1/16” hex wrench. DO NOT install Vandal Resistant Stop Cap at this time
FLUSH OUT SUPPLY LINE
-
A Open Control Stop
-
B Turn on water supply to flush line of any debris or sediment
-
C Close Control Stop
INSTALL VACUUM BREAKER FLUSH CONNECTION
NOTE
If cutting Vacuum Breaker Tube to size, note that Critical Line (C/L) on Vacuum Breaker must typically be 6” (152 mm) above fixture. Consult Code for details.
- A Slide Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud Flange over Vacuum Breaker Tube.
- B Insert Tube into Fixture Spud.
- C Hand tighten Spud Coupling onto Fixture Spud.
INSTALL FLUSHOMETER
- A Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece into Control Stop. Tighten Tailpiece Coupling by hand
- B Align Flushometer directly above the Vacuum Breaker Flush Connection by sliding the Flushometer Body IN or OUT as needed. Tighten Vacuum Breaker Coupling by hand.
NOTE
Maximum adjustment of the Sloan Adjustable Tailpiece is 1/2” (13 mm) IN or OUT from the standard 4-3/4” (121 mm) (centerline of Flushometer to centerline of Control Stop). If roughing-in measurement exceeds 5-1/4” (133 mm), consult factory for longer tailpiece
- C Align Flushometer Body and securely tighten first the Tailpiece Coupling (1), then the Vacuum Breaker Coupling (2), and finally the Spud Coupling (3). Use a wrench to tighten these couplings in the order shown.
WHEN RETROFITTING AN EXISTING VALVE, START HERE. REMOVE COMPONENTS FROM
EXISTING FLUSHOMETER (RESS RETROFIT INSTALLATIONS ONLY)
- A Remove Control Stop Cap.
- B Turn off water supply at Control Stop. Push Valve Handle to relieve water pressure.
- C Remove Outside and Inside Covers and old Inside Parts Kit.
- D Remove old Handle Assembly and Gasket.
- E Install Chrome Handle Cap with Gasket to handle opening on Flushometer Body. Tighten Chrome Handle Cap securely
NOTE
An extra H-553 Tail O-ring is included in the event leakage occurs if the
valve is repositioned during the installation of the new Optima Plus. USE ONLY
AS NEEDED.
G2/ECOS FLUSH VOLUME
The Flush Volume of the G2/ECOS is controlled by the Regulator in the Flex Tube Diaphragm Kit. Regulators are identified by color.
IMPORTANT
LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED
ON FIXTURES OR FLUSHOMETERS.
ASSEMBLE FLEX TUBE DIAPHRAGM TO G2/ECOS ASSEMBLY
-
A Make sure Flush Volume Regulator is Installed Past O-ring
-
B Insert diaphragm into hole in base of G2/ECOS Assembly. O-ring must be fully inserted into the hole.
-
C Push Diaphragm securely against underside of G2/ECOS Assembly. Place entire Assembly onto the Valve Body.
NOTE
Sensor Lens must face directly forward. Rotating the Sensor to either side will decrease the Sensor’s ability to detect a target.
TIGHTEN LOCKING RING
- A Thread Locking Ring onto Valve Body.
B Use Strap Wrench provided to tightly secure Locking Ring.
IMPORTANT
The Locking Ring must be installed down past the valve body threads by at least one thread. If difficulty is experienced installing the Locking Ring, turn the Locking Ring back and forth, each time working it further down the threads. The Locking Ring will act as a thread chaser in the event there has been a build-up of matter on the threads of the old valve body.
If retrofitting the Optima Plus onto a †Zurn valve body, a special Locking Ring must be used (identified by a machined groove around the ring).
Order the Optima Plus with the “Z” variation to receive the unit supplied with this Ring.
REMOVE TAB TO ACTIVATE SENSOR MODULE
- A Remove all removable objects in sensor view area and remove the Tab located over the Override Button to activate the Sensor Module. The sensor module will perform the start-up routine for one minute with LED blinking.
- B After the start-up routine is complete, for the first ten (10) minutes of operation, a Visible LED Light flashes in the Sensing Window of the Optima Plus Flushometer when a user is detected.
NOTE
The start-up routine will be 1 minute long and allows the sensors to adapt to
the surrounding environment. It is VERY IMPORTANT that no non-permanent
targets (i.e. persons, buckets, covers, etc) are present at this time. The
start-up routine consists of a long (3 seconds) LED light ON, followed by slow
LED light blinking in for 1 minute. At the end of the routine the sensor will
show ONE long (2 seconds) LED light ON for lithium battery or TWO long (2
seconds each) LED light ON pulses for alkaline to complete the routine. Only
at this time can the non-permanent objects be present.
The brands and/or products names referenced herein may be subject to trademark rights of their respective owners. Use of the brands and names is for identification purposes only and does not imply affiliation with or endorsement by Sloan.
TEST SENSOR OPERATION
The G2/ECOS has a factory set sensing range:
Water Closet Models – 22” to 42” (559 mm to 1067 mm) Urinal Models – 15” to
30” (381 mm to 762 mm)
The factory setting should be satisfactory for most installations. If a
range adjustment is required, refer to the Range Adjustment instructions on
this page.
- A Test Sensor with Cover in Place.
- B Step away from Sensor and listen for “CLICK.”
- C Step away from Sensor and listen for “CLICK.” *16 seconds-BT Water Closet Models
ADJUST CONTROL STOP AND INSTALL VANDAL RESISTANT STOP CAP
- A Open Control Stop COUNTERCLOCKWISE ½ turn from closed position.
- B Activate Flushometer by placing hand in front of Optima Plus Sensor Lens for ten (10) seconds (or press override button) and then moving it away.
- C Adjust Control Stop after each flush until the rate of flow delivered properly cleanses the fixture.
IMPORTANT
The flushometer is engineered for quiet operation. Excessive water flow creates noise, while too little water flow may not satisfy the needs of the fixture. Proper adjustment is made when plumbing fixture is cleansed after each flush without splashing water out from the lip AND a quiet flushing cycle is achieved.
IMPORTANT
The Control Stop should never be opened to the point where the flow from the valve exceeds the flow capability of the fixture. In the event of a valve failure, the fixture must be able to accommodate a continuous flow from the valve.
- D Install Control Stop Cap onto Control Stop. For RESS retrofit applications, reuse Stop Cap from existing valve. In complete valve installations, a new Stop Cap is provided. For G2 models, follow the instructions packaged with the Free Spinning Vandal Resistant Stop Cap.
OPERATION
-
A continuous, INVISIBLE light beam is emitted from the G2/ ECOS Sensor.
-
After the user enters the beam’s effective range for 8-16 seconds, (22 to 42 inches (559 mm to 1067 mm) for closet installations and 15 to 30 inches (381 mm to 762 mm) for urinal installations), the beam is reflected into the Scanner Window to activate the Output Circuit. Once activated, the Output Circuit continues in a “hold” mode for as long as the user remains within the effective range of the sensor.
-
When the user steps away, the loss of reflected light initiates an electrical “one-time” signal that activates the flushing cycle to flush the fixture (1 second for urinal, 3 seconds for closet). The Circuit automatically resets and is ready for the next user.
RANGE ADJUSTMENT (ADJUST ONLY IF NECESSARY)
The G2/ECOS has a factory set sensing range:
Water Closet Models – 22” to 42” (559 mm to 1067 mm) Urinal Models – 15” to
30” (381 mm to 762 mm) The Factory setting should be satisfactory for most
installations. If the range is too short (i.e., not picking up users) or too
long (i.e., picking up opposite wall or stall door) the range can be adjusted.
Note: Water does not have to be turned off to adjust range.
Make sure to remove all the non-permanent targets in sensor view area. Push manual override button for 20-30 seconds. the LED in the G2 sensor starts slow blinking. Release the button during the LED blinking. (For BT models, press manual override again for 20-30 seconds).The G2 will enter into distance setting mode. The setting mode will run for one minute.
When further assistance is required, please contact Sloan Technical Support at: +1.888.SLOAN.14 (+ 1.888.756.2614) or visit us online at: sloan.com
NOTE: To automatically check battery strength, troubleshoot, diagnose and report issues with a wireless device, use the Sloan Smart Phone APP. The APP is available free-of-charge at the Apple iPhone APP store for iOS devices or the Google Play APP store for Android devices. For more information about the APP and its capabilities please visit Sloan.com.
To communicate with your flushometer, wave your hand 3 times in front of
sensor within 10 seconds to activate your product or press and hold the
override button for 12 seconds.
IMPORTANT
WHEN ADJUSTING RANGE FOR URINAL SENSOR, MAKE SURE TO SET-UP A PROPER TARGET IN FRONT OF URINAL SENSOR.
BATTERY REPLACEMENT
When required, replace batteries with four (4) AA-Size Batteries.Note: Water
does not have to be turned off to replace batteries Loosen the two (2) Screws
on top of unit. Remove the complete Cover Assembly. Lift the Sensor Module
from its Plate. Unplug the Electrical Connector from Battery Compartment
Cover. Loosen the Retaining Screw on Battery Compartment Cover and remove
Battery Compartment Cover. Install four (4) AA-Size Batteries exactly as
illustrated.Install Battery Compartment Cover and secure with Retaining Screw.
Note: Water only has to be turned off to replace batteries for Sloan
Optima MC models
IMPORTANT
NEVER INSTALL MIXED BATTERY TYPES: (CARBON ALKALINELITHIUM), PRIMARY AND SECONDARY CELLS (NON RECHARGEABLE VS RECHARGEABLE) REPLACE ALL 4 BATTERIES AT THE SAME TIME WITH FRESH BATTERIES FAILURE ON THE ABOVE CAN REDUCE BATTERY LIFE, CAUSE BATTERY LEAKAGE, AND RESULT IN PRODUCT DAMAGE
Make certain that Battery Compartment Cover is fully compressed against Gasket
to provide a seal; Do Not overtighten. Plug the Electrical Connector into the
Battery Compartment Cover. Reinstall the Sensor Module onto the Plate.
Reinstall the complete Cover Assembly onto the Plate. Tighten the two (2)
Screws on top of the unit.
IMPORTANT
LAWS AND REGULATIONS PROHIBIT THE USE OF HIGHER FLUSHING VOLUMES THAN LISTED ON FIXTURES OR FLUSHOMETERS.
NOTE
THE EBV-46-A BEAM DEFLECTOR IS NO LONGER REQUIRED OR AVAILABLE FOR THE G2/ECOS
TROUBLESHOOTING (when servicing solenoid, rotating locking ring, servicing diaphragm, servicing vacuum breaker or spud, turn off water supply at control stop)
CARE AND CLEANING
DO NOT use abrasive or chemical cleaners to clean flushometers as they may dull the luster and attack the chrome or special decorative finishes. Use ONLY soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, the Flushometer should be protected from any splattering of cleaner. Acids and cleaning fluids can discolor or remove chrome plating
References
- Water-Efficient Commercial Bathroom Products | Sloan
- Water-Efficient Commercial Bathroom Products | Sloan
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>