namron 600W Glassovn Panel Instruction Manual

June 9, 2024
NAMRON

namron 600W Glassovn Panel

GLASSOVN PANEL

600W/800W/1000W

220-240V~ 50-60Hz IP24

List heater in modern design, suitable for most environments.
Electronic thermostat with program setting. Bright LCD display placed at the top of the heater for easy operation.
Delivered with wall bracket. Indoor use only.

Effect: 600W/800W/1000W
Operating voltage: 220-240V~50-60Hz
IP Rating: IP24
Electronic LCD display and thermostat.
Included 1.6 m cable and plug.

ASSEMBLY OF THE HEATER

  1. Drill holes in the wall. Distance between holes: See the form (a).
  2. Attach the clips onto the wall.
  3. Push the heater into the clips and use screws to thighten the clips.

a


600W

800W

1000W

| 13cm 26cm 32cm





USE WITHOUT PROGRAM

  1. Turn on the “POWER SWITCH”, the display will show the room temperature and day symbol **(FIG. 1).

**

  1. Press “ON/OFF”, the heater will be in standby mode. Press “ON/OFF” again to start heating, and the heating symbol will appear.
  2. Press “+” or “-” to set the temperature you want. After you have set the temperature you want, the display will go back to show the room temperature after a few seconds. The temperature can be adjusted between 5°C~35°C. Factory default setting is 20°C.

USE WITH WEEKLY PROGRAM

  1. Turn on the “POWER SWITCH”, the display will show the room temperature and day symbol (FIG. 1).
  2. Press “ON/OFF”, the heater will be in standby mode. Press“ON/OFF” again to start heating, and the heating symbol will appear.
  3. Press “PROG” , to adjust the day and clock setting (FIG.2).

Press “PROG” the day symbol will blink , press “+”or “-“ to set the day of the week ,1 is Monday -7 is Sunday . Press “PROG” again and the time will blink, press “+” or “-” to set the time of the day. Press “PROG” when finished to end
the clock setting.
NOTE: If you don`t press any key during the process, the blinking will be stopped in10seconds. The heater will work in the wrong program period.

  1. Press “PROG” for 3 seconds under working mode, the display will show the weekly program setting (FIG.3).

  2. Press “+” or “-” to choose the day you want to set the program, the day symbol will blink for the relevant day.

  3. Press “PROG” again and the hour will blink, press “+” or “-” to choose the hours you want to set the program ,7:16 means 7am to 4pm.The time zone symbol will appear. ( **FIG4.)

**

  1. Press “PROG” again and the temperature will blink, press “+” or “-”to choose the temperature you want to set the program, 25:17 means 25°C in the program period and 17°C outside the program period.
  2. Press “PROG” and the day symbol will blink, to continue the rest of the days in the week you want to set the program. Press “MOON” to choose default setting temperature for the hours you have not programed, default setting temperature is 15°C.
  3. Press “TIMER” button after program setting, the heater will directly start the weekly program working mode (FIG.4), the clock symbol will appear on the display.
    NOTE: The time setting should be done before the program setting, so the heater can work under correct program period.

Window open remind| In case of a window is open in the room, the heater has a window opening remind function. If the temperature drops more than 5°C within 10minutes, the window symbol on the LCD display will be blinking rapidly, press any key on the display can stop it. Then the heater will be working as the previous program. If it it blinking continually over 10 minutes, the heater will be automatically work as Anti-frost mode ( 10°C), until someone presses any key on the display, then the heater will work as the previous program.
---|---
Power cut remind| In case of a power outage, the display will start to blinking indicating that a power outage has occurred. Press any key on the thermostat to stop the blinking.

Note: The heater has a 24hour memory function. If the power is back within 24hour, the heater will work in the same program and time as previous setting.

Child Lock| The thermostat could be locked by holding down both “+”and “-“ buttons for 3 seconds. Repeat the same procedure to unlock the thermostat again.
Reset the thermostat to default setting|  Press “ON/OFF” for 5 seconds, the heater will revert to default setting.
Information for first time use| The heater should be set to maximal temperature for 30 minutes to burn the element clean. Some smell may occur.

MÅL / MEASURES

CORRESPONDING PRODUCT

BEN TIL PANELOVN: EL. NR: 5401373
HEATER FEET: EL. NR: 5401373

MOUNTING OF FEET

Wall standing heater: Before using the heater, the feet, must be fitted to the unit. These must be attached to the base of the heater using the 2 self- tapping screws provided

DO NOT COVER

SAFETY

Do not cover the heater surface, the heater can become very hot and must be placed at a safe distance from flammable material. Disconnect power during maintenance. If using an extension cord it must be as short as possible and be extended when the oven is on

Information requirment for the electric local space heaters

Model identifier(s):5401387

Item| Symbol| Value| Unit| Item| Unit
Heat output| Type of heat input, for electric storage local space heaters only (select one)

Nominal heat output

|

Pnom

|

0.5-0.6

|

kW

| manual heat charge control, with integrated thermostat|

No

Minimum heat output (indicative)|

Pmin

|

0.50

|

kW

| manual heat charge control with room and/or outdoor temperature

feedback

|

No

Maximum continuous heat output|

Pmax,c

|

0.60

|

kW

| electronic heat charge control

with room and/or outdoor temperature feedback

|

No

Auxiliary electricity consumption|  |  |  | fan assisted heat output| No
At nominal heat output| elmax| N/A| kW| Type of heat output/room temperature control (select one)
At minimum heat output| elmin| N/A| kW| single stage heat output and no room temperature control| No
In standby mode| elSB| 0.00016| kW| Two or more manual stages, no room temperature control| No
 |  |  |  | with mechanic thermostat room temperature control| No
 |  |  |  | with electronic room temperature control| No
 |  |  |  | electronic room temperature control plus day timer| No
 |  |  |  | electronic room temperature control plus week timer| Yes
 |  |  |  | Other control options (multiple selections possible)
 |  |  |  | room temperature control, with presence detection| No
 |  |  |  | room temperature control, with open window detection| Yes
 |  |  |  | with distance control option| No
 |  |  |  | with adaptive start control| No
 |  |  |  | with working time limitation| No
 |  |  |  | with black bulb sensor| No
Contact details| Namron AS – Nedre Kalbakkvei 88B, N-1081 Oslo – NORWAY
Model identifier(s):5401388

Item| Symbol| Value| Unit| Item|
Heat output| Type of heat input, for electric storage local space heaters only (select one)

Nominal heat output

|

Pnom

|

0.67-0.8

|

kW

| manual heat charge control, with integrated thermostat|
Minimum heat output (indicative)|

Pmin

|

0.67

|

kW

| manual heat charge control with room and/or outdoor temperature

feedback

|
Maximum continuous heat output|

Pmax,c

|

0.80

|

kW

| electronic heat charge control

with room and/or outdoor temperature feedback

|
Auxiliary electricity consumption|  |  |  | fan assisted heat output|
At nominal heat output| elmax| N/A| kW| Type of heat output/room temperature control (select one)
At minimum heat output| elmin| N/A| kW| single stage heat output and no room temperature control|
In standby mode| elSB| 0.00016| kW| Two or more manual stages, no room temperature control|
 |  |  |  | with mechanic thermostat room temperature control|
 |  |  |  | with electronic room temperature control|
 |  |  |  | electronic room temperature control plus day timer|
 |  |  |  | electronic room temperature control plus week timer|
 |  |  |  | Other control options (multiple selections possible)
 |  |  |  | room temperature control, with presence detection|
 |  |  |  | room temperature control, with open window detection|
 |  |  |  | with distance control option|
 |  |  |  | with adaptive start control|
 |  |  |  | with working time limitation|
 |  |  |  | with black bulb sensor|
Contact details| Namron AS – Nedre Kalbakkvei 88B, N-1081 Oslo – NORWAY
Model identifier(s):5401389

Item| Symbol| Value| Unit| Item| Unit
Heat output| Type of heat input, for electric storage local space heaters only (select one)

Nominal heat output

|

Pnom

|

0.85-1.0

|

kW

| manual heat charge control, with integrated thermostat| __

No

Minimum heat output (indicative)|

Pmin

|

0.85

|

kW

| manual heat charge control with room and/or outdoor temperature

feedback

| __

No

Maximum continuous heat output|

Pmax,c

|

1.00

|

kW

| electronic heat charge control

with room and/or outdoor temperature feedback

| __

No

Auxiliary electricity consumption|  |  |  | fan assisted heat output| No
At nominal heat output| elmax| N/A| kW| Type of heat output/room temperature control (select one)
At minimum heat output| elmin| N/A| kW| single stage heat output and no room temperature control| No
In standby mode| elSB| 0.00016| kW| Two or more manual stages, no room temperature control| No
 |  |  |  | with mechanic thermostat room temperature control| No
 |  |  |  | with electronic room temperature control| No
 |  |  |  | electronic room temperature control plus day timer| No
 |  |  |  | electronic room temperature control plus week timer| Yes
 |  |  |  | Other control options (multiple selections possible)
 |  |  |  | room temperature control, with presence detection| No
 |  |  |  | room temperature control, with open window detection| Yes
 |  |  |  | with distance control option| No
 |  |  |  | with adaptive start control| No
 |  |  |  | with working time limitation| No
 |  |  |  | with black bulb sensor| No
Contact details| Namron AS – Nedre Kalbakkvei 88B, N-1081 Oslo – NORWAY

 

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals