aruba 610 Series Campus Access Points Installation Guide

June 9, 2024
aruba

aruba 610 Series Campus Access Points

The Aruba 610 Series Campus Access Points are high-performance, dual-radio tri-band devices that support the IEEE 802.11ax WLAN standard in the 6GHz band (Wi-Fi 6E) as well as the 5GHz and 2.4GHz bands. Additionally,this series delivers capacity with MIMO (Multiple-Input, Multiple-Output) and OFDMA (Orthogonal Frequency Division Multiple Access) technologies while also supporting IEEE 802.11a/b/g/n/ac wireless devices.

Hardware Overview

1 E0 Ethernet Port
2 E1Ethernet Port

Figure 4 Access Point Rear View

aruba610 Series-Campus-Access-Points-3

LED
The LED displays located on the front panel of the access point indicate the system status of the access point.

System Status LED

Table 1: System Status LED

aruba610 Series-Campus-Access-Points-7

  1. Blinking: one second on, one second off, 2 seconds cycle.
  2. Flashing off: mostly on, fraction of a second off, 2 seconds cycle.
  3. Flashing on: mostly off, fraction of a second on, 2 seconds cycle.

Radio Status LED
The Radio Status LED table below is applicable to 2G, 5G, and 6G labels.

Table 2: Radio Status LED

aruba610 Series-Campus-Access-Points-8

LED Display Settings

The LEDs have three operating modes that can be selected in the system management software:

  • Default mode: refer to Table 1 and Table 2.
  • Off mode: all LEDs are off
  • Blink mode: all LEDs blink green (synchronized)

To force the LEDs into off mode or back to software defined mode, press the reset button for a short duration (less than 10 seconds).

Bluetooth Low Energy Radios
610 Series access points are equipped with an integrated BLE and 802.15.4 radio that provide the following capabilities:

  • location and asset-tracking applications
  • wireless console access
  • IoT gateway applications

Console Port
The console port is a Micro-B connector is located on the back of this device. Use the proprietary AP-CBL-SERU cable or AP-MOD-SERU module (sold separately) for direct management of this device when connected to a serial terminal or laptop. For pin-out details, refer to Figure 5.

Ethernet Ports
The 610 Series access points are equipped with two active Ethernet ports (E0 and E1). Both ports are 100/1000/2500/5000 Base-T, auto-sensing MDI/MDX, which supports uplink connectivity when linked by an Ethernet cable. Refer to Figure 6 for a detailed port pin-out.

aruba610 Series-Campus-Access-Points-5

Kensington Lock Slot
The 610 Series is equipped with a Kensington lock slot for additional physical security.

USB Interface
The USB 2.0 interface located on the top of the is 610 Series compatible with selected cellular modems and other peripherals. When active, this port can supply up to 5W/1A to a connected device.

Reset Button
The reset button located on the bottom of the device can be used to reset the access point to factory default settings or turn off/on the LED display.
Use one of the following methods to reset the access point to factory default settings:

  • To reset during normal operation
    • Hold the reset button for more than 10 seconds while the access point is running.
    • Release the reset button.
  • To reset during power up, hold the reset button while the access point is powering up.
    The system status LED will flash again within 15 seconds indicating that the reset is completed. The access point will now continue to boot with the factory default settings. To toggle the LED display between Off and Blinking, during the normal operation of the access point, shortly press and release the reset button using a small, narrow object, such as a paperclip.

Power
Both Ethernet ports support PoE-in, allowing the AP to draw power from an 802.3at/802.3bt PoE power source. When the AP is powered by both E0 and E1 ports simultaneously, the AP can be configured by management software to source PoE power from either port, or to combine power from both ports an 802.3af source may be used.

NOTE
PoE input rating is 57V max|0.3A. 0.3A is per pair of wires in Ethernet cable. Ethernet cable has 4 pair of wires totally.

Before You Begin

Refer to the sections below before beginning the installation process
FCC Statement: Improper termination of access points installed in the United States configured to non-US model controllers will be in violation of the FCC grant of equipment authorization. Any such willful or intentional violation may result in a requirement by the FCC for immediate termination of operation and may be subject to forfeiture (47 CFR 1.80).

Pre-Installation Checklist
Before installing your 610 Series access points, ensure that you have the following:

  • A mount kit compatible with the AP and mount surface

  • Cat5E or better UTP cable with network access Optional items

  • A compatible power adapter with cord

  • A compatible PoE midspan injector with power cord

  • An AP-CBL-SERU console cable

  • An AP-MOD-SERU console module
    Also, make sure at least one of the following network services is supported:

  • Aruba Discovery Protocol (ADP)

  • DNS server with an “A” record

  • DHCP Server with vendor specific options

NOTE

  • Aruba, in compliance with governmental requirements, has designed the 610 Series access points so that only authorized network administrators can change configuration settings. For more information about AP configuration, refer to theAP Software Quick Start Guide.
  • If a power adapter other than the Aruba-approved adapter is used in the US or Canada, it should be NRTL listed, with an output rated 12V DC, minimum 4A, marked “LPS” and “Class 2,” and suitable for plugging into a standard power receptacle in the US and Canada.

Identifying Specific Installation Locations

Use the access point placement map generated by Aruba 650 Series RF Plan software application to determine the proper installation location(s). Each location should be as close as possible to the center of the intended coverage area and should be free from obstructions or obvious sources of interference. These RF
absorbers/reflectors/interference sources will impact RF propagation and should be accounted for during the planning phase and adjusted for in RF plan.
Identifying Known RF Absorbers/Reflectors/Interference Sources
Identifying known RF absorbers, reflectors, and interference sources while in the field during the installation phase is critical. Make sure that these sources are taken into consideration when you attach an access point to its fixed location.

RF absorbers include:

  • Cement/concrete—Old concrete has high levels of water dissipation, which dries out the concrete, allowing for potential RF propagation. New concrete has high levels of water concentration in the concrete, blocking RF signals.
  • Natural Items—Fish tanks, water fountains, ponds, and trees
  • Brick

RF reflectors include:

  • Metal Objects—Metal pans between floors, rebar, fire doors, air conditioning/heating ducts, mesh windows, blinds, chain link fences (depending on aperture size), refrigerators, racks, shelves, and filing cabinets.
  • Do not place an access point between two air conditioning/heating ducts. Make sure that access points are placed below ducts to avoid RF disturbances.

RF interference sources include:

  • Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones)
  • Cordless headset such as those used in call centers or lunch rooms

CAUTION
Portable RF communications equipment should be used no closer than 30 cm (12 inches) to any part of the access point. Otherwise, degradation of the performance of this equipment could result.

Access Point Installation

CAUTION
All Aruba access points should be professionally installed by an Aruba- Certified Mobility Professional (ACMP). The installer is responsible for ensuring that grounding is available and meets applicable national and electrical codes. Failure to properly install this product may result in physical injury and/or damage to property.

  • For indoor use only. The access point, AC adapter, and all connected cables are not to be installed outdoors. This stationary device is intended for stationary use in partly temperature-controlled weather-protected environments (class 3.2 per ETSI 300 019).ls.

Software
Aruba 610 Seriesrequires ArubaOS or Aruba Instant8.10.0.0 or later. For instructions on choosing operating modes and initial software configuration, refer to theAP Software Quick Start Guide.

Aruba access points are classified as radio transmission devices, and are subject to government regulations of the host country. The network administrator(s) is/are responsible for ensuring that configuration and operation of this equipment is in compliance with their country’s regulations. For a complete list of approved channels in your country, refer to the Aruba Downloadable Regulatory Table at https://www.arubanetworks.com/techdocs/DRT/Default.htm.

Verifying Post-Installation Connectivity

The integrated LEDs on the access point can be used to verify that the access point is receiving power and initializing successfully (see Table 1 and Table 2). Refer to the AP Software Quick Start Guide for further details on verifying post-installation network connectivity.

Ethernet

  • l E0: 100/1000/2500/5000 Base-T auto-sensing Ethernet RJ-45 Interfaces
  • l E1: 100/1000/2500/5000 Base-T auto-sensing Ethernet RJ-45 Interfaces

Power

  • Power over Ethernet (IEEE 802.3at and 802.3bt compliant)
  • 12V DC power interface, support powering through AC-to-DC power adapter
  • Maximum power consumption: Refer to datasheet

Environmental

  • Operating
    • Temperature: 0°C to +50°C (+32°F to +122°F)
    • Humidity: 5% to 95% non-condensing
  • Storage
    • Temperature: -40ºC to 70ºC (-40ºF to 158ºF)
    • Humidity: 5% to 95% non-condensing

Regulatory Information
For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number (RMN). The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number RMN is not the marketing name or model number of the product.

The following regulatory model numbers apply to the 610 Series

  • AP-615 RMN: APIN0615

ArubaNetworks provides a multi-language document that contains country- specific restrictions and additional safety and regulatory information for all Aruba access points. This document can be viewed or downloaded at www.arubanetworks.com.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s author-ity to operate this equipment.

CAUTION
Toute modification effectuée sur cet équipement sans l’autorisation expresse de la partie responsable de la conformité est susceptible d’annuler son droit d’utilisation.

Brazil
Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados.
O uso deste equipamento é restrito a ambientes fechados e proibido em plataformas petrolíferas, carros,
trens, embarcações e no interior de aeronaves abaixo de 3.048 m (10.000 pés).

Safety and Regulatory Compliance

RF Radiation Exposure Statement: This equipment complies with RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 7.87 inches (20cm) between the radiator and your body for 2.4 GHz, 5 GHz, and 6GHz operations. This transmitter must not be co- located or operating in conjunction with any other antenna or transmitter.
The device could automatically discontinue transmission in case of absence of information to transmit, or operational failure. Note that this is not intended to prohibit transmission of control or signaling information or the use of repetitive codes where required by the technology.

Industry Canada
This Class B digital apparatus meets all of the requirements of the Canadian Interference-Causing Equipment Regulations.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Eco-nomic Development Canada’s licenceexempt RSS(s). Operation is subject to the following two conditions: (1)

This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
When operated in 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems.

EU & UK Regulatory Conformity
The Declaration of Conformity made under Radio Equipment Directive 2014/53/EU as well as the United Kingdom’s Radio Equpment Regulations 2017/UK is available for viewing at: www.hpe.com/eu/certificates. Select the document that corresponds to your device’s model number as it is indicated on the product label. Compliance is only assured if the Aruba approved accessories as listed in the ordering guide are used.
https://www.arubanetworks.com/assets/og/OG_610Series.pdf.

Wireless Channel Restrictions
5150-5350MHz band is limited to indoor only in the following countries; Austria (AT), Belgium (BE), Bulgaria
(BG), Croatia (HR), Cyprus (CY), Czech Republic (CZ), Denmark (DK), Estonia (EE), Finland (FI), France (FR), Germany (DE), Greece (GR), Hungary (HU), Iceland (IS), Ireland (IE), Italy (IT), Latvia (LV), Liechtenstein (LI), Lithuania (LT), Luxembourg (LU), Malta (MT), Netherlands (NL), Norway (NO), Poland (PL), Portugal (PT), Romania (RO), Slovakia (SK), Slovenia (SL), Spain (ES), Sweden (SE), Switzerland (CH), Turkey (TR), United Kingdom (UK) (NI).

Radio Frequency Range MHz Max EIRP
BLE/Zigbee 2402-2480 10 dBm
  2412-2472 20 dBm
  5150-5250 23 dBm
  5250-5350 23 dBm
Wi-Fi 5470-5725 30 dBm
  5725-5850 14 dBm
  5945-6425 23 dBm

CAUTION

Lower power radio LAN product operating in 2.4 GHz and 5 GHz bands. Please refer to the ArubaOS User Guide/Instant User Guide for details on restrictions.

European Union and United Kingdom
This device is limited for indoor use. Use in trains with metal-coated windows (or similar structures made of materials with comparable attenuation characteristic) and aircraft is permitted. Operations in the 6GHz band are blocked by firmware for some countries pending adoption of spectrum. Refer to Aruba DRT release notes for details.

Open Source Code
This product includes code licensed under the GNU General Public License, the GNU Lesser General Public License, and/or certain other open-source licenses.
A complete machine-readable copy of the source code corresponding to such code is available upon request. This offer is valid to anyone in receipt of this information and shall expire three years following the date of the final distribution of this product version by Hewlett Packard Enterprise Company.
To obtain such source code, send a check or money order in the amount of US $10.00 to:

Hewlett Packard Enterprise Company
Attn: General Counsel
6280 America Center Drive
San Jose, CA 94089
USA

Warranty
This hardware product is protected by an Aruba warranty. For more details, visit www.hpe.com/us/en/support.html

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals