STUDER X-Connect Pre-Wired Frame User Guide

June 9, 2024
STUDER

quick guide
xconnect

designed and assembled
by studer in Switzerland

Introduction

Congratulations !
You just purchased the xconnect, a mounting frame to assemble a multi-xtender system. The xconnect will offer you a flexible and economical solution for high power systems based on inverters from the xth product range. Indeed, it will make the cabling of centralized, parallel, 3-phase or even parallel + 3-phase systems much easier.

General Information

Exclusion of liability
Studer disclaims all responsibility and liability for damage, costs or losses resulting from an installation that does not comply with the instructions, a faulty operation or inadequate maintenance. The use of studer equipment is in any case under the responsibility of the customer.

Read carefully the safety and operation instructions / Installation must be entrusted to qualified personnel / Check the user manual online / Need help ?

STUDER X-Connect Pre-Wired Frame - sambol 2| STUDER X-Connect Pre-Wired Frame - sambol 3| | STUDER X-Connect Pre-Wired Frame - qr code
---|---|---|---

https://eqrcode.co/a/Ecznzt

Mounting and installation

Storage and content

STUDER X-Connect Pre-Wired Frame - Fig 1

  1. Pre-installed DC circuit breakers
  2. Pre-installed DC fuses
  3. Pre-installed DIN rails

Mounting place
The batteries should only be installed by qualified personnel.

STUDER X-Connect Pre-Wired Frame - sambol 5

Cabling possibilities

**Cabling flexibility**
The xconnect has been designed to offer a large range of cabling possibilities in order to best adapt to each environment.
Four Ø 50 mm holes on each side of the frame enable input and output cabling (AC and/or DC) by either plugs/sockets or glands or installation channels. These  inputs/outputs can likewise be carried out downwards via channels. If this later solution is chosen, the installer will take care not to seal the apertures down of the fixing frame. These apertures allow on one side the cables input and on the other side the xtender ventilation air entrance.
Studer Innotec highly recommends the installation of plugs/sockets at the input/output of the system.
This allows a simple and secure by-pass of the system during maintenance operations.
The output cabling as well as the glands (or 400VAc plug and socket) are not supplied with the xconnect.

STUDER X-Connect Pre-Wired Frame - Fig 2

Multi units

Multi xconnect systems
It is possible to combine up to 9 xtender inverter-chargers (3 xconnect systems) allowing to reach a total power of 72kW.

Compatible with :

Wiring

STUDER X-Connect Pre-Wired Frame - Fig 3

Assembly

STUDER X-Connect Pre-Wired Frame - Fig 4

STUDER X-Connect Pre-Wired Frame - Fig 5

STUDER X-Connect Pre-Wired Frame - Fig 6

Maintenance and recycling

Maintenance and recycling
Except for the periodic check of the connections (tightening, general condition), the rcc does not require any particular maintenance. To dispose of this product, please use the service for the collection of electrical waste and observe all obligations in force in the place of purchase.

Serial Number :
Installed by :
Date :
Signature :

Call our specialists +41 27 205 60 80
or visit studer-innotec.com/support
Studer Innotec SA
rue des Casernes 57
1950 Sion, Switzerland
info@studer-innotec.com

© All rights reserved
Studer Innnotec SA – V1.0

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals