ABESTORM Guardian SNS65 120 Pints Crawl Space Dehumidifiers User Manual
- June 9, 2024
- ABESTORM
Table of Contents
- Guardian SNS65 120 Pints Crawl Space Dehumidifiers
- Warranty Registration
- Safety Notes
- Identification
- Electrical Supply
- Principle of Operation
- Installation
- Key Function
- Indicator Lights
- Remote Control Instructions
- Operating Instructions
- Guardian SNS65 Diagram
- Maintenance
- Dehumidifier Storage
- Ducting Installation
- Troubleshooting
- Water Pump Matainence and Application
- Limited Warranty
- Limited Warranty Exclusions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Guardian SNS65 120 Pints Crawl Space Dehumidifiers
User’s Manual
Guardian SNS65
Abestorm Solutions INC.
Add: 8605 SANTA MONICA BLVD#/9525
WEST HOLLYWOOD, California,90069 USA
E-mail: saales@abestorm.com
Note: as we keep upgrading our product, we reserve the right to modify the product without notice in advance.
Warranty Registration
Congratulations on purchasing a new Guardian Dehumidifier. Your new
dehumidifier comes with an extensive warranty plan. To register, simply fill
out and return the warranty form provided in the dehumidfier box.
Be sure to note your dehumidifier serial number as you will need it for
registration.
Safety Notes
- The Guardian Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances). If non-grounded wiring is used, all inability reverts to owner and the warranty is voided.
- Guardian Dehumidifiers should only be maintained and repaired by a qualified technician.
- Guardian Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level. Operating the unit in any other orientation could allow water to flood electrical components.
- Always unplug dehumidifier before moving.
- If there is a chance that water flooded the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting.
- To ensure proper operation, neither the inlet nor discharge should be positioned against a wall The inlet requires a minimum of 6′ clearance and the discharge requires a minimum of 6′ clearance.
- For better use of the dehumidifier, both air inlet and air outlet should be facing the open area of the space.
- Do not insert your fingers or any object into the inlet or discharge.
- All work on the dehumidifier should be done with the unit “off’ and unplugged.
- Do not use water to clean the exterior of the machine. To clean unit, unplug from power, then use a damp cloth to wipe exterior.
- Do not stand on the machine or use it as a device to hang clothes.
Identification
For future reference, write down the model, serial number, and date of
purchase for your dehumidifier.
This is extremely helpful if you need to seek assistance in the future. The
data label on the side of your unit has the key characteristics of your
specific machine.
Model Number: Guardian SNS65
Serial Number: —————— Date of Purchase: ——————
For additional questions concerning your dehumidifier, the following options are available:
- Contact your installing contractor
- E-mail: sales@abestorm.com
Electrical Supply
Power Supply: 115 V, 60 Hz AC, Single Phase
Outlet Requirement: 3-Prong, GFCl
Circuit Protector: 15 Amp
WARNING:
240 Volts AC may cause serious injury from electric shock.
To reduce risk of injury:
- Disconnect electrical power before servicing
- Only plug unit into grounded electrical circuit
- Do not use an extension cord.
- Do not use a plug adapter
Principle of Operation
The Guardian Series Dehumidifier utilizes its integral humidistat to monitor the conditioned space. When the relative humidity goes above the selected set point, the dehumidifier will energize. Air is drawn across an evaporator coil, which is cooler than the dew point of air. This means moisture will condense out of the air. The air is then reheated through the condenser coil and distributed back into the room.
Installation
The area to be controlled should be sealed with a vapor barrier. If unit is
installed in a crawlspace, all vents should be sealed.
WARNING:
Do not install your dehumidifier in a corrosive environment. Some liquid vapor
barriers dry via “solvent evaporation”. Always make sure that barrier is
completely dry and area is throughly ventilated before installing
dehumidifier.
Step #1: Place dehumidifier on a level surface.
Do not place directly on vapor barrier. For example, use blocks, or pavers to
create a level surface.
If the unit is handled in such a manner that the compressor did not remain in
the upright position, you will need to place it on a level surface, then wait
a minimum of 2 hours before turning “on”.
Step #2: Set Up Drain Line.
The included drain line attaches to unit via a compression type fitting on the
discharge end of the unit. To attach drain line, remove the compression nut
and slide it over the end of the hose to be at tached to unit. Slide
compression nut side of hose over the insert on the compression fitting com
pletely. Tighten compression nut.
Step #3: Plug unit into 15 amp grounded circuit.
Key Function
-
Power Key
• Use this button to turn the dehumidifier on and off. Press once to turn machine on. You will hear one beep and the light will illuminate green. Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a one minute fan delay on shutdown. -
Arrow Buttons
• Use the up and down arrow button to set the desired humidity setpoint on the display screen.
The setpoint can be any number between 36- 90%. Creating a setpoint means that when the indoor humidity is lower than the set point, the machine will stop automatically. Conversely, when the indoor humidity is higher than the set level, the unit will operate. NOTE: The humidty levels displayed are approximate only (+/- 5%) -
Continuous Mode
• To switch into continuous mode, simply use the down arrow to set the humidity below 36%. The Cont. light should illuminate green on the display board to indicate that you have successfully switched into continuous mode. The display screen will show “CO”,
• When set to continuous, the dehumidifier will run constantly, regardless of the humidity level.
To stop the machine, turn the unit off or switch back to normal humidistat operation. If you would like to switch back to normal humidistat operation, simply move the setpoint above 36%. -
Central Control
• This mode is not applicable on the Guardian SNS65.
• Central Control light should off at all times when not connected to the AC. -
Manual Drain Button
• For extended storage or movement of the machine, press the “Drain” button to remove water from the integral pump’s reservoir.
Indicator Lights
-
Humidity Display Screen
• The display screen has two functions:
• When the unit is powered on, it shows the humidity of the space.
• While setting the desired humidity level, the screen will show the set humidity. After a brief delay, the display will revert to current humidity level. -
Power Indicator Light
• This light indicates that the unit is properly powered on and ready to operate. Always make sure the unit is “off” prior to performing any service.
• When the power light is blinking, it means that the unit has reached the humidity setpoint. -
Continuous Mode/Auto Defrost Light
• When this light illuminates green, it indicates that the dehumidifier is set to continuous operation mode.
• When the light glows red, it means the unit is in auto defrost mode and clearing the evaporator coil of any ice buildup. -
Compressor Light
• When the compressor light glows red, it indicates the compressor has been initiated but is currently warming up.
• Once the compressor light switches to green, it indicates the compressor is in working status.
Remote Control Instructions
Guardian Dehumidifiers can be controlled using an optional remote accessory.
The Guardian Remote Control connects to your Sentinel Series Dehumidifier via
a 25’ CAT 5 cable. The remote control contains an integrated sensor which
gives you multiple options for remotely controlling your unit, in addition to
monitoring the conditions surrounding the dehumidifier.
One application for the remote control is to install the dehumidifier in one
room with the conditioned air ducted into a second room that contains the
remote. For example, the dehumidifier could be installed in a laundry room and
ducted into a living room. The remote would then be mounted in the living
room so the remote sensor can control the humidity and provide easy controls
for the user.
Another useful application for the remote control is if the dehumidifier is in
area that’s difficult to access on a regular basis. For instance, if your
dehumidifier is installed in your crawl space, the remote could be mounted in
your living space or garage. This provides you with an easy way to monitor
the dehumidifier.
-
On/O ff (Power)Button
Press the on/off button and the machine will start running (one beep). Press the button again to the turn the machine off. -
Up Button ▲ /Down Button ▼
Use the Up and Down arrow buttons to adjust the humidity level. -
Mode M
Use the Mode button to switch between dehumidification and aducted application.
• The symbol on the display board indicates the sensor on the remote control is being utilized.
• The symbol on the display board indicates the sensor on the dehumidifier is being utilized. -
Temperature T
Press the temperature button to display the current temperature on the screen. Press the button again to turn off the display. -
Continuous C
Press this button to switch the unit into continuous mode. Cont. will appear on the display to indicate continuous mode. -
Drain Pump P
Use this button if the unit will not be in use for an extended period of time. Pressing the drain pump button will remove water from the pump reservoir, so the unit can be safely moved or stored. THIS FUNCTION IS ONLY AVAILABLE ON THE Guardian SNS65,Guardian SNS90.
NOTE: Symbols indicated above will only appear when the dehumidifier is powered on.
Operating Instructions
-
Start the Machine
Press the power key to turn the machine on. -
Adjust the Settings
Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%). -
Stop the Machine
Press the power key again and the machine will stop. Note the fan will continue to operate for 1 minute after the unit has turned off. NOTE: Do not disconnect the power cord to force unit to stop. Always use the power button. -
Water Drainage
During normal operation, the Guardian SNS65 will automatically drain by the force of gravity. If you want to move or store your machine, wait at least 10 minutes to allow the machine to completely defrost, then lean unit gently towards drain to ensure that it is completely drained.
Guardian SNS65 Diagram
Maintenance
WARNING:
Always unplug the unit before doing any maintenance.
Cleaning the machine body
Use a soft damp cloth to clean exterior of unit. Do not use any soap or
solvents.
Replacement filter and steps
- As shown in the figure above, tilt the filter into the filter slot.
- Push the filter upwards until it touches the top of the air filter slot.
- Push the bottom of the filter into the filter groove.
- Let the filter slide down freely.
Cleaning the filter
-
Unplug the unit. ****
-
Push up the filter.
-
Clean the filter mesh by vacuuming
or washing with warm water (no soap or solvents). -
Be sure filter is completely dry before restarting unit.
Coil Maintenance
- Once per year, clean the coils with an approved coil cleaner.
- Coil cleaner should be a self rinsing, foaming cleaner such as WEB® Coil Cleaner.
Dehumidifier Storage
If the unit will be stored for an extended period of time, complete the following steps:
- Turn off the unit and allow to dry.
- Wrap and secure the power cord.
- Cover the filter mesh.
- Store in a clean, dry space.
Ducting Installation
- Maximum length for ducting= 6’
Note: The supply duct adapter is standard on all units.
|
---|---
Removing Supply Duct Adapter
If it is necessary to remove the adapter, place hand at bottom of adapter and
use your fingers to pull out and down on base of adapter This will lift hooks
out of cover holes.| Installing Supply Duct Adapter
To install adapter, line up with holes on the side of unit and push up from
base of adapter.
|
Flex Duct Installation
Rotate the flex duct counter- clockwise.| Flex Duct Removal
Rotate flex duct clockwise.
Troubleshooting
Symptom | Cause | Solution |
---|---|---|
Machine Won’t Run | Power Supply | Verify that there is power to the outlet and |
that the plug is properly installed in outlet
Room Temperature Over 105°F (Display HI) or Below 33°F(Display LO)| The unit
is outside the operating temperature range. Modify the room conditions so the
temperature is between 33°F-105°F and operation will commence.
Low Air Flow| Air Filter is Clogged| Clean the filter mesh according to
instructions listed in manual.
Air Inlet or Outlet is Blocked.| Clear the blockage from inlet or outlet.
Loud Noise| Machine Is Not Level| Move the dehumidifier to flat, firm ground.
Filter Mesh is Blocked| Clean the filter mesh according to instructions listed
in manual.
Trouble Code E:1| El =Humidity Sensor Issues| Check to ensure that wire is
connected at both ends. If no issues are visible, the sensor may be faulty.
Trouble Code E: 4| Pump has failed| Verify that the pump is working. If so,
unplug the unit for two minutes, then restart.
Trouble Code: HI or LO| Room Temperature Over 105°F or Below 33°F(Display LO)|
The unit is outside the operating temperature range. Modify the room
conditions so the temperature is between 33°F-105°F and operation will
commence. lf room conditions are within temperature range, replace defective
sensor.
Pump Alarm- Trouble Code E4
If a pump alarm is shown on the display, complete the following steps:
-
Reset the unit by disconnecting the power cord and then reconnecting it.
NOTE: UNIT WILL NOT FUNCTION UNTIL ERROR CODE HAS BEEN CLEARED. -
Manually check to see if pump is operational by pressing the drain button. Check if the pump energizes and de-energizes properly. Additionally, check to see if any water purged from the system.
-
If you haven’t cleaned the system recently, check the discharge line for an obstruction, then clean the balance of the pump system (see “Maintenance” on page 7 for details).
-
Replace the hoses and/or pump, if maintenance alone isn’t sufficient.
Water Pump Matainence and Application
Normal use of water pump
-
Determine whether the forced drainage function is useful
When the power is on, press the “Drain” button, the water pump runs normally, the pumping water is normal, there is no vibration and noise, and the water flows smoothly. -
Determine whether the automatic drainage function of the water pump water level line is useful
Press the “ ” button, the machine will perform dehumidification work. When the water level in the water collector reaches a certain height, the floating ball rises, and the water pump automatically enters the water pumping state, without vibration and noise, and the water flows smoothly. -
Turn on the power and run the dehumidifier
If there is no abnormality in the forced drainage function and the automatic drainage function, the user can rest assured to use this equipment. If the water pumping is abnormal, the machine will display an error code of “E4”, at this time, the user can simply repair the pump failure by himself. When the user is unable to repair, contact the manufacturer via email or phone.
Usage of gravity drainage pipe(It can choose gravity drain or pump drain with the working environment)
For gravity drainage, the dehumidifier should be placed on a plane with a
certain height. Pull out the screw tooth rubber plug at the outlet of the
water collector of the dehumidifier, and plug in the water pipe.
The condensate dripping from the coil will be discharged along the water pipe,
which can be collected into the water storage container or discharged out of
the room (Note: the water pipe should not be higher than the dehumidifier and
should be discharged towards the ground).
**Water pump function**
- Solve the inconvenience that gravity drainage can only place the machine at a fixed height, it can be put in various places in the house for work.
- The drainage pipe can be laid at will, without space restriction, up to 19.6 ft.
- It can be allowed to pump water automatically when it reaches a certain water level, or it can be pumped manually at any time, which is more flexible and convenient.
- The advantages of the water pump itself, low noise, low vibration, small size, long life, self-priming function, simple maintenance and easy replacement.
- Use the rubber stopper plug the drain hole when you use the pump drain.
The fault judgment and maintenance method of the water pump
Problem judgment when “E4” error code appears:
- The drainage hose is blocked or bent and deformed by foreign matter.
- The drainage height exceeds the standard.
- Water level switch failure.
- Water pump failure or expiration of service life.
- Internal water pump hose is blocked or bent and deformed by foreign matter.
Pump repair method
- Use a Phillips screwdriver to unscrew the five screws on the water pump panel, you can see the fixed state of the water pump.
- Use a Phillips screwdriver to loosen the four screws of the water pump fixing bracket.
- Pull out the hose fixed in the water storage box, and take out the water pump for replacement.
- Install the new water pump to its original position according to the above steps.
Guardian SNS65 Spare Parts
All Sentinel Models-Parts
Part#| Description
S-100| Remote Control Package(cable + remote)
S-101| Remote Control
S-102| Remote Control Cable,25′
S-107| Fiexible Supply Duct,72″
S-108| Main Control Board
S-109| Display Board
S-110| RH/Temperature Sensor
Guardian SNS65 Parts
Part#| Description
S-500| Fan Motor
S-501| Complete Fan Assembly
S-502| Fan Capacitor
S-503| Compressor
S-504| Compressor Capacitor
S-505| Coil Assembly
S-508| RH/Temperature Sensor Cable
S-509| Display Cable
S-510| CAT 5 Prot Internal Cable
S-513| Foot, adjustable
S-514| Condensate Pump Assembly
Guardian SNS65 Filters
Part#| Description
S-517| MERV-8 Filter
Limited Warranty
This limited warranty starts from the date of purchase. Abestorm Solutions
Inc. warrants to the original purchaser that this Abestorm product is free
from manufacturing defects in material or workmanship for the limited warranty
period of:
Six (6) Month parts and labor. This includes the shipments charges for
replacement parts or unit.
One (1) year parts and labor. This does not include the shipment charge
to send the defective product back to be repaired or replaced.
Three (3) years parts and labor on Refrigeration System ONLY (Compressor,
Condenser, and evaporator). Transportation cost, not included.
Five (5) years parts on Refrigeration System ONLY (Compressor, Condenser,
and evaporator). Transportation cost, not included.
This limited warranty is valid only on products purchased from the
manufacturer or Abestorm authorized dealer and operated, installed, and
maintained according to the instructions included in this user guide or
furnished with the product. Abestorm Solutions Inc will not provide in- home
service during or after the warranty period. You may be responsible for the
shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact Abestorm at
888-276-9833 or
sales@abestorm.com. A proof of purchase or order
number is required to receive warranty service. During the applicable warranty
period, a product will be repaired or replaced at the sole option of Abestorm.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:
- Damage occurs in uses for which this product was not intended for.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty. ****