Rating Voltage | Rating Frequency | Motor Power | Light Power |
---|---|---|---|
AC220 -240V | 50 Hz | 200W | 2*1.5W |
AC220-240V | 50 Hz | 230W | 2*1.5W |
Installation
installation
Please do not contact the steel and wires inside the wall in order to avoid
electric shock.
- The range hood must have to earth. It has a 3- pin plug. The plug must be connected to a socket with earthing. The earthing could offer an electrical circuit to avoid electric shock in case of electricity leakage.
- Please make sure the electricity supply system in your home (current, voltage, connecting wires) can meet the requirements of range hood’s normal supply load.
- Please do not use high capacity fuse in electrical circuits and select the correct ones as required on rating label.
Preparation and confirmation before installation
-
CD Wall strength
The wall that the range hood is placed must be hard enough to bear the weight of range hood. -
Height of mounting
The suitable height of mounting shall be 350-400mm above the cooking stove. The real installation height is subject to the construction of kitchen and user’s height. The installation instruction of gas stove has given the suitable installation distance, please take it into consideration. -
Before mounting the hood to the wall
-
Install the fixing plate to a certain position of chimney by using 4- ST4 screws.
-
Install the two dampers to a certain position of the chimney by using 2- M4*12 washer screws.
install the fixing hanger
Measure the installing height of the fixing hanger first, and then make a
mark of the hook holes on the wall. And then drill holes, place inflatable
colloidal particles into them, and install the fixing hanger.
lnstall the chimney cover
Lock the hang board and chimney cover by two pieces of tapping screws
(410mm). And then install the chimney cover to the top of hood. Finally,
install two pieces of tapping screws (410mm) on the side of chimney cover.
Install the hood (a single chimney cover)
The hood should be aligned to the fixing hanger on the wall (pay attention
that hood’s horizontal and vertical status). And then put down the hood-drill
holes on every marked place-place inflatable colloidal particles-hang the
hood-lock the hang board by 4*40mm tapping screws.
Product installation (single hood)
- Aim at the hanger and hang the range hood up on the wall. Mark the position of hanger and two screws on body.
- Put down the range hood–d ri 11 holes on the marks as mentioned above— insert plastic expansion bolts in the holes—Hang the range hood
u p—Fix hanger with screws (4*40mm screws) —Fix the product within the body by two screws—Connect the other end of the exhaust pipe to air outlet.
Exhaust pipe connecting to the wall outside
The other head of exhaust pipe shall be connected to the flue or the hole of
the external wall (the diameter of hole shall be 85mm).
Confirmation of installation
After installation, connect to power supply and turn on the range hood. Check
if all functions of range hood are working normally; no abnormal vibration and
no resistance to leaves of air outlet.
Function Operation
- Control Panel (subject to the real product)
Attention
- Voltage and frequency must comply with the requirements of the product. Supply socket must have reliable earthing.
- Make sure the installation of product is not connected to the steel and wires inside the wall in order to avoid electric shock.
- The wall must have sufficient strength to support the weight of range hood.
- Range hood shall be installed in a horizontal level.
- The distance between the exhaust hole and air outlet on the wall shall be less than 1.5m. When install the exhaust pipe, the air outlet shall not be too high to avoid oil flowing backward.
- Rang hood shall be used when gas or other fuels burning. The room must be well ventilated.
- Do not bark rang hood directly. Gas burning without cooking or burning on the pan is forbidden.
- The air exhaust from range hood should not be exhausted to the flue of burning gas or other fuels.
- In case power cord is damaged, it shall be repaired by professional personnel or sent back to the appointed maintenance centre of our company for repair.
- Power supply must be cut off before changing lamps. New lamps must be the same specification as the current ones.
- Clean the oil on filter regularly. And clean the oil on wind wheel and volute or other components if necessary. If not follow the instruction in manual to clean range hood, it might cause fire hazard.
- Wear rubber gloves when clean range hood in order to prevent the injury of metal.
- It should be careful when clean the impeller to prevent deformation of impeller or rubbing off the counterweight, which might affect the balance, cause noise and vibration.
- It is strictly to prevent water seepage into switches, motor, lamps and other electric components when clean range hood.
- Nonprofessional personnel are forbidden to change the internal wiring.
Maintenance
- Suggestion
- Clean the surface of shell every three days.
- Clean the oil on filter regularly
- Full maintenance shall be done every half year. It should not be implemented by nonprofessional personnel.
- When doing internal maintenance, the following steps shall be followed:
- Shut off power supply.
- Take off filter and clean by soft brush. Put it back in place after drying for next maintenance.
- Pull out smoke cover oblique upwards. Unscrew air inlet cover and air frame and take it off. Loosen the knob clockwise. Hold the wheel axle and pull out the impeller. Immerge the impeller into cleaning fluid for around 10 minutes.
- Clean the oil on the impeller with soft brush. Nonprofessional personnel are not allowed to implement.
- Put impeller back in place. Tighten the knob counterclockwise. Then install air inlet board, air inlet cover and smoke cover in order.
- To keep the range hood working in good condition for long term, please keep maintenance regularly.
Common faults and solutions
If there are any abnormal phenomena happen during operation, please stop using and unplug the power cord and check the faults. Nonprofessional persons are not allowed to dismantle the machine. The common faults and solutions are as follows:
Fault | Reason | Solution |
---|
Lamp not on, but motor is working
| Poor wire connection| Repair or change the wires
Lamp is damaged| Change the lamp
Poor connection between lamp and socket| Repair or change
The quarlz lamp transformer burns out| Change transformer
Lamp is not on and motor isn’t working
| Poor connection between plug and socket| Repair or change
Power cord is broken| Change the power cord
Fuse of power board is broken| Change fuse
Lamp is on, motor is not working
| Thermal cutout of motor is working| Wait for a while and turn on again
Condenser burns| Change the condenser
Motor burns| Change the motor
Faults of power board and control board| Contact maintenance center
Strong vibration, noise increases
| Check if the hanging is strong enough| Hang the range hood firmly
The connecting pieces of the fixed screws
are loose
| Tighten the screws
Volute standing fixed screws are loose| Tighten the screws
Motor fixed screws are loose| Tighten the screws
Impeller instalation is not in place| Install in place
Impeller is damaged and balance piece is lost| Change the impeler
Poor suction
| Too much oil on fitter| Clean the filter
The air convection in the kitchen is too big or
space sealing is too tight
| Reduce air convection, open doors
and windows moderately
Higher instalation height| Adjust to appropriate height
Exhaust pipe is too long or too many circles| lnsial according to the manual
Outdoor wind is too strong| Non technical faults