hansgrohe AXOR CARLTON Thermostat Mixer Instruction Manual

October 30, 2023
hansgrohe

hansgrohe AXOR CARLTON Thermostat Mixer

Safety Notes

Gloves should be worn during installation to prevent crushing and cutting injuries.
**** The shower system may only be used for bathing, hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/ or sensoric impairments must not use this shower system without proper supervision. Persons under the influence of alcohol or drugs are prohibited from using this shower system.
The hot and cold supplies must be of equal pressures.

Installation Instructions

The fitting must be installed, flushed and tested after the valid norms!

Technical Data

Operating pressure: max. 1 MPa
Recommended operating pressure: 0,1 – 0,5MPa
Test pressure: 1,6MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature: max. 80°C
Recommended hot water temp.: 65°C
Rate of flow by 0,3 MPa: approx. 43 l/min anti-pollution function

Symbol description

| Do not use silicone containing acetic acid!
---|---

Assembly

Assembly
Assembly
Assembly
Assembly
Assembly

Fault Cause Remedy
Insufficient water Supply pressure inadequate Check water pressure (If a

pump has been installed check to see if the pump is working).
Regulator filter dirty| Clean filters
Shower filter seal dirty| Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water pipe, or vice versa, when mixer is closed| Backflow preventers dirty or leaking| Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with temperature set| Thermostat has not been adjusted| Adjust thermostat
Hot water temperature too low| Increase hot water temperature to 42 ºC to 65 ºC
Temperature regulation not possible| Temperature regulator dirty or calcified| Clean temperature regulator, exchange if necessary
For new installations: basic body incorrectly connected (should be: cold right, hot left) or installed with 180º rotation| Install function block turned through 180º
Safety stop button not operating| Spring defective

Button calcified

| Clean spring and/or button, exchange if necessary

Safety Function

The desired maximum temperature for example max. 42º C can be pre-set thanks to the safety function.

Safety Function
Safety Function
Safety Function

Adjustment

After the installation, the output temperature of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat.

Adjustment

  Maintenance

  • To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
  • The mixer is equipped with non return valves. The non return valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year). At this time, please also check the filter (A) situated on the MTC-thermoelement (94282000). After assembling the MTC-thermoelement, it is necessary to check the water temperature at the take off point as described under the headline „adjustment“. Before the adjustment, please check, if the warm water supply is activated and the maximum temperature of the warm water is available at the take off point.

Maintenance
Maintenance
Maintenance
Maintenance
Maintenance

Dimensions

Starck
10710000

Starck X
10716000

Montreux
16810XXX

Carlton
17710XXX

Carlton
17715XXX

Massaud
18740000

Citterio M
34715000

Steel
35710800

Uno
38375000

Citterio
39710000

Citterio
39715000

Bouroullec
19700000

Test certificate

| PA-IX| DVGW| SVGW| ACS| WRAS| MCA| KIWA
---|---|---|---|---|---|---|---
10710000| 9712/II| | X| X| X| X| X
10716000| 9712/II| | | X| | X| X
16810XXX| 9712/II| | | X| | X| X
17710XXX| 9712/II| | X| X| X| X| X
17715XXX| 9712/II| | X| X| X| X| X
18740000| 9712/II| | | X| | X| X
35710800| 9712/II| | X| X| X| X| X
34715000| 9712/II| | | X| | |
37710000| 9712/II| | X| X| X| X| X
37715000| 9712/II| | X| X| X| X| X
38375000| 9712/II| | X| X| X| X| X
39710000| 9712/II| | X| X| X| X| X
39715000| 9712/II| | X| X| X| X| X
19700000| 9712/II| | | X| X| |

Spare parts

Spare parts
Spare parts
Spare parts

Operation

Other Model

Starck
10710000

Starck X
10716000

Montreux
16810XXX

Carlton
17710XXX

Carlton
17715XXX

Massaud
18740000

Citterio M
34715000

Steel
35710800

Uno
38375000

Citterio
39710000

Citterio
39715000

Bouroullec
19700000

Hansgrohe · Postfach 1145 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282 · Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com · Internet: www.hansgrohe.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

hansgrohe User Manuals

Related Manuals