SLOAN EAF-3X0 Electronic Sensor Activated Lavatory Faucets
Faucet Variations
-ISM Integral Spout Temperature
Mixer
PRIOR TO INSTALLATION
Prior to installing the Sloan OPTIMA Plus® EAF-3X0 Series faucets, install the items listed below. Also, refer to rough-in illustrations.
- Lavatory/sink
- Drain line
- Hot/Cold water supply lines or pre-tempered water supply line
IMPORTANT:
- ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.
- FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
- KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON COMPRESSION FITTINGS.
Trim Plates
When the EAF faucet is installed on a sink that has three (3) hole punchings,
a trim plate should be used. Trim plates must be specified and ordered
separately.
ETF-312-A Trim Plate for 4” (102 mm) Centerset Sink
ETF-510-A Trim Plate for 8” (203 mm) Centerset Sink
Tools Required for Installation
- 13mm open wrench or nut driver for faucet retainer nut
- 3/4” open end wrench for female end of flex hose
FAUCET ROUGH-IN
INSTALL FAUCET
-
Remove nut, faucet retainer and gasket.
DO NOT remove the o-ring from base of faucet.
DO NOT remove sensor label until step.4 -
Install faucet with o-ring into the center hole in deck or lavatory – 1-5/16” (33 mm) minimum hole required.
NOTE: if installing the faucet on a three (3) hole sink, a trim plate should be installed at this time.
SLIDE GASKET OVER FLEX HOSE(S) AND SECURE
INSTALL STRAINER AND FLEX HOSE ONTO SUPPLY STOP. OPEN SUPPLY STOPS.
IMPORTANT: Flush dirt, debris, and sediment from supply line(s) before connecting flex hose(s).
- Install strainer and flex hose(s) onto supply stop.
- Tighten the flex hose(s) (with strainer in place) securely to the supply stop(s).
- Open supply stop(s).
Note:
If water flows immediately upon opening supply stops, the solenoid is in the
open position, and will be cycled to the closed position during the sensor
startup sequence in Step 5.
CONNECT TO THE POWER SUPPLY (EAF-300 MODELS ONLY)
REMOVE LABEL FROM SENSOR
- Remove label from sensor window
ACTIVATE FAUCET
- Activate Faucet by holding installation instructions approximately 1-1/2” (38 mm) in front of the sensor window until red light appears, then remove instruction sheet. Faucet will run for four (4) seconds and the range will automatically adjust to its environment. Wait ten (10) seconds after water shuts off before using faucet.
- Activate Faucet and check for leaks. If faucet does not function, refer to the Troubleshooting section of this instruction manual.
SET AND FIX TEMPERATURE
- Adjust lever to set temperature.
- Optional – To fix temperature, set lever to the desired position, then remove lever and plug hole with cap
BATTERY REPLACEMENT
Note: Replace battery when RED LED indicator flashes each time faucet is in use or when faucet stops functioning.
- Close supply stop(s).
- Loosen screw with hex wrench and remove cap.
- Move battery retainer tab away from battery. Remove old battery. Dispose of properly. Wait 15 seconds before
- Install new battery.
- Replace cover and tighten screw with hex wrench.
- Insert a new 6V type CR-P2 lithium battery. The RED LED will flash for one (1) minute.
- Wait ten (10) seconds before using faucet
SETTINGS
IR-Click Feature
The IR-Click is a detector located in the sensor window of the faucet spout
that allows the user to place the faucet into the following function modes:
Continuous Run, Temporary Off and Auto Set Range Adjustment.
To use the IR-Click, cover bottom half of sensor with finger, wait 2 seconds
for Orange light, then remove finger. When in programming mode, each touch of
IR-Click will produce a quick Orange flash.
Function | Press Button | LED Signal |
---|---|---|
Temporary OFF (2 min) | 1. 1 time for 2 seconds |
2. 2 times (double push)
| 1. LED Orange (1)
2. LED Red pulsating flashes
Reset:| 1 time or will reset automatically after 2 mins|
Continuous Run 2 min default setup
(adjustable from 1-20 min)
| 1. 1 time for 2 seconds
2. 1 time for 3-5 seconds
| 1. LED Orange (1)
2. Water flows after releasing
Reset:| 1 time or will reset automatically after 2 mins|
Auto Set Range Adjustment
Details Shown in Next Section
| 1. 1 time for 2 seconds
2. 2 times (double touch)
3. 1 time for 4 seconds then hold till requested range is reached
4. Release
| 1. LED Orange (1)
2. LED Red blinks
3. LED Red (1-8)
4. LED Orange (1)
SENSOR RANGE ADJUSTMENT
After inserting the new battery and opening the supply stops, wait 15 seconds, remove and then reinsert the battery.
- IR activation (see page 5). To enter programming mode place finger on IR-Click (covering bottom half of sensor) 1 time for 2 seconds and remove, ORANGE light will come on. Then, place finger 2 times then remove. Light on sensor should blink RED to indicate programming mode.
- Cover IR-Click (bottom half of sensor) until LED flashes RED 4 times – hold IR-Click until LED flashes 1 to 8 times from minimum to maximum range.
- See diagram below. Release when requested range is reached.
- Wait until LED flashes ORANGE
SENSOR RANGE ADJUSTMENT DIAGRAM
12/24 LINE PURGE FEATURE
This feature will operate the faucet every 12 or 24 hours since last use, or
if not used, to prevent stagnant water conditions.
Default purge duration is two minutes.
Consult factory regarding other timing options
Steps to activate purge line feature:
- Activate IR: cover lower part of sensor window with a white card/paper until LED flashes ORANGE to confirm program mode is active.
- Cover lower part of sensor window once more with a white card/paper for approximately 24 seconds (ignore LED indications during this period). Release when requested program is reached. (See LED indications to right.)
HOT LIMIT STOP ADJUSTMENT
- Close supply stop(s).
- Loosen screw with hex wrench and remove cap.
- Adjust temperature to desired limit
- Adjust screw to meet limit setting
- Replace cover and tighten screw with hex wrench.
- Open supply stop(s).
- Wait ten (10) seconds before using faucet.
OPERATION
As the user’s hands enter the beam’s effective range, the beam is reflected back into the sensor receiver and activates the solenoid valve allowing water to flow from the faucet. Water will flow until the hands are removed or until the faucet reaches its automatic time out setting.
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean
faucets that may dull the luster and attack chrome or special decorative
finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or
towel.
While cleaning the bathroom tile, protect the faucet from any splattering of
cleaner. Acids and cleaning fluids will discolor or remove chrome plating.
PARTS LIST
SLOAN® LIMITED WARRANTY SUMMARY
Sloan Valve Company (“Sloan”), warrants its products against defects in
materials and workmanship, excluding damage caused by matters beyond Sloan’s
reasonable control. Instructions for filing claims can be found in the Limited
Warranty which can be obtained at www.Sloan.com or by requesting a free copy
by telephone at 888.756.2614. Sloan will repair or replace your defective
product, or provide a refund, as your exclusive remedy. This is only a general
summary of Sloan’s Limited Warranty so it is important to note that the
specific terms, conditions, limitations and exclusions, including the duration
of warranty coverage for your particular Sloan product, are contained in the
actual Sloan Limited Warranty. The Limited Warranty is subject to applicable
laws in your country, state, province or other jurisdiction—and disputes
arising under the Limited Warranty are to be resolved by binding arbitration
unless you provide Sloan with an opt-out notice no later than 30 days after
your purchase date. In case of a conflict with this summary, the terms and
conditions set forth in the complete Limited Warranty will prevail.
pose of resale. This warranty does not cover the life of batteries.
THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
Sloan
10500 Seymour Avenue
Franklin Park, IL 60131
P: 847-671-4300 / 800-9-VALVE-9
F: 847-671-4380 /
800-447-8329
customer.service@sloanvalve.com
sloan.com
References
- Water-Efficient Commercial Bathroom Products | Sloan
- Water-Efficient Commercial Bathroom Products | Sloan
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>