3-Wire (No Neutral Required) Switch Compatibility & Wiring Configurations
Switch Model Numbers
- CSWONBLBWF1NN/ST1P
- CSWONBLPWF1NN/ST1P
- CSWONBLTWF1NN/ST1P
- CSWDMBLBWF1NN/ST1P
- CSWDMOCBWF1NN/ST1P
Requirements
- Ground wire is required (Wire is usually green, green with a yellow stripe, or copper)
- Wi-Fi 802.11 b/g/n @ 2.4 GHZ is required
- Minimum Load 15 Watts
- If you are using less than 15 Watts, non-dimmable LED bulbs, or C by GE or Cync Smart Bulbs on the circuit, you will need to use the included Bulb Adaptor. Use the optional Fixture Adaptor (available separately) where the Bulb Adaptor will not fit. Contact Customer Support at 1-844302-2943 for details.
Compatibility
- Rating 120V AC 60Hz
- Neutral wire is not required (Wire is usually white or grey and is not required)
- Works with halogen, incandescent, and LED bulbs, including Cync/C by GE Smart Bulbs
- Not for use with ceiling fans
- LED up to 1.25 amps (150 Watts)
- Incandescent/halogen up to 5 amps (450 Watts)
Wiring Configuration | Compatible | User Experience |
---|---|---|
3-Way Install | Yes | Two switches on the same circuit controlling the same |
light(s). All switches on the circuit
must be a Cync Smart Switch.
4-Way/Multi-Way Install| No| Four or more switches on the same circuit
controlling the same light(s). Having more
switches on the circuit requires more syphoned current from the load which
will cause
inconsistent functionality and a poor experience. Due to the instability of
this setup, this
install is not compatible.
California 3-Way| Yes| See wiring diagram below for details.
Dead End 3-Way| Yes| See wiring diagram below for details.
Knob and Tube Wiring| No| This wiring setup is not compatible or supported due
to the risk of lower grade copper,
and the potential of deterioration/snapping of the wires.
Mixing different switch brands
with Cync Smart Switches on
the same circuit.| No| All switches on the same circuit must be a Cync Smart
Switch. Our switches will not
function properly if they are mixed with a basic on/off switch, or a non-Cync
Smart
Switch on the same circuit.
Mixing Cync Dimmers and Cync
On/Off Switches on the same circuit| No| Mixing 3-Wire Dimmers and 3-Wire
Switches on the same circuit is not compatible. They
all need to be either all 3-Wire Dimmers or 3-Wire Switches.
Light Bulb/Fixture
Compatibility| Compatible| User Experience
---|---|---
CFL| Yes| For dimmers, select non-dimmable load since CFL’s cannot dim.
Florescent Fixtures with
Electronic Ballasts| No| Not compatible due to high capacitance and high
switching frequency within the
ballast circuitry which may cause interference with our switches.
Magnetic Ballasts| No| Not compatible due to high capacitance in the circuit
from starting circuitry that may
cause interference with our switches.
LED Drivers| No| Due to the variety of types and different specifications of
LED Drivers, we cannot
guaruntee compatibility with our switches.
Fans| No| Our 3-Wire Switches are not compatible for fan switches. If you have
neutrals in your
switch box, we recommend our Fan Speed Smart Switch.
Pool Lights and/or Pumps| Yes, but| If it is within our current switch rating
(120V 60HZ 1/4HP motor) and protected with a
GFCI.
Single Pole
3-Way
California 3-Way
Dead End 3-Way
3 Wire (No Neutral Required) Switch Compatibility and Wiring
Configuration Guide
Documents / Resources
| GE
Lighting CSWONBLBWF1NN-ST1P Smart Dimmer Light Switch Motion
Sensor
[pdf] Instructions
CSWONBLBWF1NN-ST1P, Smart Dimmer Light Switch Motion Sensor, Switch Motion
Sensor, Motion Sensor, Dimmer Light Switch, Light Switch, Switch
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>