Sanyipace 41110000 Sewer Inspection Camera User Manual
- June 4, 2024
- Sanyipace
Table of Contents
Sanyipace 41110000 Sewer Inspection
**Camera User Manual**
Please contact us at the first time if you got any issue with the product
SanyiMrchan@gmail.com
Attention: The illustrations and screens which in this manual are to explain the operation of this product. Due to the difference in version upgrades and production batches, they might alittle different from the machine you actually use. If the content in this manual does not match your machine, please refer to the machine!
Notice
- Please read the manual carefully before using it.
- Handle it carefully during operation, avoid throwing down or pressing it heavily.
- If the users disassemble or deliberately damage the machine, it will beyond the warranty.
- Please turn off the display and pull out all the connection joints after using it.
- Please copy your information before connecting the TF card.
- Don’t suddenly cut off the power during recording and playing. This may damage the product and video files.
Application:
- pipe dredging machine
- Pipe inspection camera Pipe tool
- underground pipelines, air conditioning pipelines, oil and gas pipelines
- Rescue work in a small space
- For underground exploration
- Underwater riverbed research
- Underground TV
Specification
Camera and cable:
Sensor: 1/3 CMOS
Resolution: 1000TVL
Camera Diameter:22MM * 42MM
Camera Type: with 512HZ Locator
Detect Depth (Cable Length): 20m / 30m / 50M (optional)
LED: 12 pieces of white LED beads(Brightness can be adjustable)Viewable Angle:
145 degree
Camera Material: stainless steel/ IP68 Waterproof
LCD Monitor:
Size:9inch
Monitor input voltage: DC 12V
Display Resolution: 1024*600
Monitor Image: Color
Memory Card: includes 8GB card, (Max support 32 GB card)
Menu language: Chinese /English Optional
Operation Method: Press button
Operate Temperature:-20-60 degree
Storage Temperature:-30-80 degree
Battery Box:
Charger: DC12.6V 1200MA
Charging time: about 5 hours
Battery capacity: Lithium battery 12V 4500mah
Battery working time: about 6-8 hours
LCD Monitor Operation
-
Turn on
Connect all cables, turn on the power switch on battery box and screen power button, then system is starting up
-
Menu setting: (needs to exit recording mode)
press MENU/EXIT button to enter, “<” “>” button to select, REC button to confirm, press MENU/EXIT button to exit operation, can set REC/Photo/Time/Contrast/Brightness/Colorful, Language: Chinese/English/Russian Optional
Recording operation: Press REC button once time to record, press it again to stop
Playback: Press PLAY/+ to enter, press < > to select video, press REC/- to play, press MENU/EXIT to delete, save or preview
Meter Counter Function
Screen will display distance by meter and feet at the same time automatically
Press the clear key first before using this function, it will be countedthe meter when the wire reel rotates, and the data is displayed on the screen in real time.
Camera Probe with Built-in 512hz Locator inside
It transmit a special frequency signal through the built-in chip
Transmit frequency∶512HZ
Output wave∶Sine wave
Transmit Distance: about 5 Meter
512HZ Receiver
The receiver has a built-in induction coil to receive the magnetic signal from the pipeline, and the coil generates an induced current to calculate the direction and position of the transmitter. There are two receiving modes: Far (note: about 5M) and Near (note: about 1 meter). Then adjust the sensitivity knob, peak mode (maximum) or null mode (minimum) to locate the transmitter
Receiver Technical Parameters:
Receiver Frequency: 512HZ
Detect Distance: about 5m
Battery: 3.7V 3000MAH built-in lithium battery
Charger: 5V 1A
Charger time: about 6 hours
Battery Indicator: 3 gear, it is flashing when battery is low
Battery working time: about 10 hours
Signal strength:6 gear
Speaker:Support
Detect Mode : Far/ Near
How to Use Receiver to Detect Camera Position:
- Turn on the detector, set the sensitivity knob to the strongest gear
- Set it to far mode to detect first. When the signal light is on, it means that you have entered into the 512hz locator position within 5 meters.
- Then move forward to the direction of signal. Keep finding and moving to the strongest signal, try slowly reducing sensitivity, until find out the position which is strongest signal when sensitivity is weakest.
- After that, switch the button on the left side of the handle to the near mode, and set the sensitivity knob to the strongest gear to continue detect, keep moving and finding the signal source. when it reach out the strongest signal position, the receiver has entered into the 512hz locator position within 1 meter.
Device Charger
Charger: input 100-240V output 12.6V 1000MA
Note: Charging time: about 5-6 hours It can’t work when the battery is less than 20%
Battery 4500mah
Wire Diagram
Cable Operation
put the cable on the hook, pull to release or push back to coil the cable.
Warranty
We provide one year warranty for the product, and free replacement within7days for any quality problems. From the day you purchased, we provide free maintenance for the normal breakdown, but for the damage caused by operation against the manual, we will charge for the cost fee for the spare parts to maintain even if product is under the warranty.
—–Contact Us—–
Go to our website to download use manual or check more Products: http://sanyipace.com/
Our Email: SanyiMrchan@gmail.com
We support spare parts replacing, please contact us at the first time when you
got issues with our product.
References