concept ZV2021 Perfect Air Smart Humidifier User Manual

June 6, 2024
concept

ZV2021

CONSUMER SAFETY INFORMATION
Note: The humidifier, as an electrical appliance, requires supervision during operation.
Note : If moisture is formed on the walls or windows, switch the humidifier off. Excessive humidity in the room may cause damage. Do not block the air inlet or outlet.

PRODUCT DESCRIPTION

  1.  Steam outlet
  2. Water tank cap
  3.  Filter
  4.  Handle
  5. Water tank
  6.  Control indicator
  7.  Base
  8. Base stand
  9.  Sensor
  10.  Power cord
  11.  Backlight

DISPLAY AND CONTROL PANEL

A Steam intensity setting
B Percentage representation of humidity
C Room temperature indicator
D Timer
E Lack of water in the tank
F Plasma
G Hot steam setting indicator
H UV
I NIGHT mode
J AUTO mode
K HEALTH mode
L BABY mode
M Humidity level setting indicator

USE

BEFORE FIRST USE

  1. Make sure the appliance is switched off and disconnected from the mains.

  2.  Place the humidifier on a flat surface at least 60 cm from the floor level and 10 cm from the wall. We do not recommend placing the humidifier on expensive furniture.
    3. Refiling the water tank:
    – Remove the tank from the base upwards.
    – Remove the cap from the water tank and pour fresh cold water into it.
    – DO NOT FILL THE WATER TANK WITH WARM OR HOT WATER, IT MAY CAUSE DAMAGE TO THE WATER TANK
    – After filling the tank, replace the cap and place the tank back on the base. Water flows automatically into the base of the appliance.

  3.  Connect the mains cable to the mains.

OPERATION GUIDELINES

  1.  Plug the humidifier into the socket according to the recommended input voltage. Then the red ON/OFF icon lights up.
  2. Touch the ON/OFF symbol to start the device. Then the display and control panel with indicators light up. The humidifier automatically starts to operate in **AUTO** mode. This symbol appears on the display with the current temperature and humidity.
  3. Press the MODE button to select from three modes: night, health and auto. Press repeatedly to switch between the modes.
    NIGHT mode – When the night mode is activated, the symbol appears on the display and the brightness of the other indicators decreases. The following functions can also be used – heating, UV, plasma and timer. After 15 seconds, the indicators automatically turn off and ON/OFF remains to flash. Touch any indicator to activate the display.

AUTO mode – When the humidifier is switched on, the auto mode is automatically activated and the **AUTO** symbol appears on the display. The humidifier checks the optimal air humidity every minute. If the air humidity is lower than the optimal humidity, the humidifier starts to operate at the highest power; if the humidity in the room is sufficient, the humidifier operates at lower power. Warm mist, UV, plasma and timer functions are available in the auto mode.
NIGHT and AUTO modes: The appliance is automatically set to optimally humidify the air depending on the room temperature. For example: The temperature of the room, in which the appliance  perates, is 24 °C and the optimal humidity is 53 %. The humidifier operates at maximum power until the optimal air humidity is reached. If the air humidity is lower than 53 %, the humidifier will operate at maximum power. When the humidity reaches 53 %, the humidifier automatically reduces the power to the minimum. The humidifier checks the air humidity every minute.

Room
temperature
– see Humidifier (C°)| ≤19| 20| 21| 22| 23| 24| 26| 27| 28| 29| 30| 31| 32| 33| 34| 35| 36| ≥37|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Air humidity
(%)| 65| 60| 58| 57| 55| 53| 45| 43| 40| 38| 37| 36| 35| 34| 32| 31| 30| 25|

HEALTH mode – When the health mode is activated, the symbol appears on the display. The warm mist and UV functions are automatically activated. The humidifier starts to operate at maximum power, the air humidity is automatically set to 60 %. If the air humidity is lower than 60 %, the humidifier will operate at maximum power. When the humidity reaches 60 %, the humidifier automatically reduces the power to the minimum. The humidifier checks the air humidity every minute.
BABY mode – Touch the indicator to activate the BABY mode. The warm mist, plasma and UV functions are automatically activated. The humidifier starts to operate at maximum power, the air humidity is automatically set to 55 %. If the air humidity is lower than 55 %, the humidifier will operate at maximum power. When the humidity reaches 55 %, the humidifier automatically reduces the power to the minimum. The humidifier checks the air humidity every minute.

  1. Press the button to select the desired humidification time. The time can be set between 1-12 hours at intervals of 1 hour, which is added by repeatedly pressing the button. If the timer function is active, the desired hour lights up on the display. To deactivate the timer, press and hold the button until “Co” appears on the display, then release the button and the timer will be deactivated.
  2. Press the to switch on the heated humidification and the indicator appears on the display. The heated humidification starts in 10-15 minutes. To switch this function off, press the button again, the indicator on the display disappears and the humidification will cool down again.
  3. Press the button to start the humidity level setting and the indicator appears on the display, select the desired humidity from 30 to 75 %. The desired air humidity can be set at intervals of 5 %. If the humidity exceeds 75 %, “Co” appears on the display and after three seconds the humidifier automatically switches to the AUTO mode. After setting the desired humidity level, the display shows the current air humidity. Press the button again to view the set value. The humidifier automatically adjusts the amount of steam according to the current humidity. – If the humidity level is set to be 1-10 % higher than the current humidity. The humidifier sets the humidification level to the first level. – If the humidity level is set to be 10-15 % higher than the current humidity. The humidifier sets the humidification level to the fourth level. – If the humidity level is set to be 15 % higher than the current humidity. The humidifier sets the humidification level to the seventh level. If the humidity exceeds the set value, the appliance stops. It starts again when the air humidity drops below the set level. Long press the button to cancel the set values, the humidifier will automatically return to the AUTO mode.
  4. Press the button to activate the plasma function, the indicator appears on the display. Press the button again to deactivate the plasma function. Long press the button to switch on/off the appliance backlight. The appliance produces positive and negative ions using high voltage. Negative ions in much larger quantities than positive ions. These ions are surrounded by molecules of water that ensure their long lifetime. The clusters of ions then surround the viruses floating in the air, breaking the membrane of the virus, which dies instantly.
  5. Press the **UV**switch on the UV function and the indicator in appears on the display. Press the button again to switch the UV function off.
  6. Swipe across the MAX-MIN button to manually adjust the steam release and the number of levels changes on the display. There are 1-7 levels of steam intensity. Swipe the symbol to the right to increase the intensity, swipe the symbol to the left to decrease the intensity. After 5 seconds of inactivity, the intensity is set and the current humidity appears on the display. For NIGHT, HEALTH, BABY and CONSTANT HUMIDITY modes, it is not possible to manually change the steam intensity.
  7. Automatic humidifier shut-off  If there is not enough water in the water tank, the humidifier automatically switches off, the low water indicator appears on the display and the appliance beeps three times (this function is disabled if you have activated the NIGHT mode). Before refilling the water tank, make sure that the humidifier is switched off and disconnected from the mains. Refill the water tank with water and switch on the humidifier. The low water indicator disappears and the humidifier restarts
  8. Regardless of the selected mode, the display and the control panel automatically dim after 15 seconds, press any button to reactivate them.

Note: Always use fresh, distilled or demineralized water to avoid any malfunction.
Adding essential oil To add essential oil, press the aroma tray to remove it. Add 1-3 drops of essential oil to the pad inside. Press the aroma tray again to secure it to the appliance body.

Water filter

  •  Ceramic balls in the filter soften hard water.
  •  Ceramic balls in the filter eliminate water odour.

Ideal relative air humidity:

  • Ideal RH for persons: 45-65 %
  • Ideal RH for therapeutic purposes: 40-55 %
  •  Ideal RH for libraries, galleries, furniture, musical instruments, etc.: 45-60 %

The humidifier uses an ultrasonic high-frequency oscillator to break water into small water droplets of a diameter of approximately 1–5 μm. The ventilation system distributes this water into the dry air, where it evaporates and the desired humidity is reached.

Remote control description

  1. ON/OFF
  2.  NIGHT mode
  3. AUTO mode
  4. BABY mode
  5. HEALTHY mode
  6. Humidity level
  7. Humidifier backlight
  8. Timer
  9. Steam heating
  10.  UV
  11. Plasma
  12.  Steam intensity

Before using the remote control for the first time, remove the plastic film from the battery.

Replacing the remote control battery
The battery is stored in the back lower part of the remote control. Press and pull out the cover with the battery. Replace the battery with a new one. Make sure that the battery is correctly inserted. Slide the cover with the battery back into the remote control.

CLEANING AND MAINTENANCE

Lack of moisture during winter can cause dry skin, nose irritation, frequent colds, sore throat, etc. Humidifiers produce
relative humidity to protect our health. Use the following maintenance instructions in order to get the best out of the
humidifier without damaging it. If you do not follow these guidelines, unwanted microorganisms can grow in water.
DAILY MAINTENANCE

  • Switch the appliance off and disconnect it from the mains prior to cleaning.
  • Open the water tank and the top of the humidifier.
  • Rinse the water tank thoroughly and remove all deposits and dirt. Clean and wipe the water tank with a clean, soft cloth or paper towel.
  •  Fill the water tank with fresh cold tap water as described in the water refill instructions.

WEEKLY MAINTENANCE

  •  Repeat the three above-mentioned daily maintenance steps.
  • Pour about 200 ml of vinegar into the reservoir and leave it for 15 minutes. Then remove the limescale in the tank, especially in the ultrasonic disk, with a soft brush.
  •  Wipe limescale and vinegar residues with a clean, soft cloth.

MAINTENANCE WARNINGS

  • NEVER submerge the appliance main unit into water.
  • Do not use any solvents or other aggressive substances to clean the humidifier.
  •  Clean the inside of the appliance with a soft cloth.
  • Clean the ultrasonic disk only with a soft brush. Clean it at least once a week. You can add 2-5 drops of vinegar to the ultrasonic disk – leave it for about 5 minutes. Then clean with the brush provided.
  •  Use a brush with fine bristles.
  •  If water has remained in the water tank, replace it at least once a week.

CLEANING OF CERAMIC FILTER BALLS
Use 1 litre of clean distilled water to clean the ball filter. If the balls are still dirty, you need to repeat the cleaning more often. For greater cleaning efficiency, immerse the ceramic balls in a glass of vinegar and leave it for 5 minutes. Then rinse the balls thoroughly and let them dry in a dry place for 4-6 hours.
STORAGE

  • Clean and dry the humidifier as described above.
  • It is recommended to store the appliance in its original packaging.
  • Do not expose it to high temperatures.

TROUBLESHOOTING

If your humidifier does not work properly, check the following possible causes.

IProblem Cause Remedy

The humidifier does not
work.| The power cord is not connected.| Plug the power cord into the socket.
The indicator is on, but no
mist is coming out of the
appliance.| There is too much water in the water tank.| Pour some water from the water tank.
No mist| Water level in the water tank is too low.| Fill the water tank with water.
Water is leaking from the water tank.| Check that the water tank is in the correct position.
The temperature of the device is too low.| Place the device at a room temperature for half an hour before use.
Deposit on ultrasonic disk| Clean the ultrasonic disk.
Weak mist output| Too much/too little water in the water tank| Pour out water from the water tank/add water to the water tank.
Deposit on ultrasonic disk| Clean the ultrasonic disk.
Water is too cold| Use water with a room temperature.
The water is not clean.| Clean the water tank and pour fresh, distilled or demineralized water into it.
White dust is formed on
the furniture.| Hard water can deposit a certain
amount of white powder on the
ultrasonic disk. The white powder
is decomposed by ultrasonic
vibrations and blows into the air
along with the mist. White powder
in the air settles on the furniture.| If the problem persists, use distilled water.
Do not forget to clean the ultrasonic disk
and the filter after a short use.
---|---|---
Water accumulates
outside the humidifier or
the surrounding area.| Saturation of moisture.| Switch off the humidifier or set it to a low
mist level.
The device is not levelled and accumulates water.| Unplug it and place it on a flat surface. Aim
the mist nozzle away from objects. Place it
on a waterproof, flat surface at least 60 cm
from the floor.
The mist has an unusual
odour.| The appliance is new.| Open the water tank and leave it in a dark
and cool place for 12 hours.
Water in the water tank is dirty or it
has been there for too long.| Clean the water tank and pour fresh,
distilled or demineralized water into it.
The device generates
unusual noise| The noise in the water tank is
caused by a low water content.| Fill the water tank.
The appliance is not placed on
a flat surface.| Move the appliance to a stable, flat surface.
The appliance has stopped
producing steam.| The air humidity is sufficient.|
The timer symbol is lit on the
display.| Refill the water tank.
The set timer is over.| Switch on the humidifier.
The display shows
incorrect humidity level.| The room is too large.| Move the humidifier to a smaller room.
Steam has gotten into the sensor.| Switch off the humidifier and leave it in place to dry properly before using a dry it again. If the sensor is still not working, contact an authorized service centre.
Control panel does not
work.| Wet hands.| Keep your hand dry. Do not handle the
appliance with wet hands.
Control panel malfunction| Contact your dealer.
Steam is coming out
outside of the steam
outlet.| The water tank is incorrectly
inserted.| Switch off the appliance and make sure that
it is not plugged in. Open the lid and insert
the water tank correctly.
The hot steam function
does not work.| The humidifier is not heated up yet.| Wait a few minutes for the appliance to heat
up to the correct temperature.
The steam is too fine.| Increase the steam release level.
The room is too cold and the steam
cools quickly.| Increase the steam release level and the
room temperature.
The remote control does
not work.| The remote control batteries are
dead.| Replace the batteries.
---|---|---
The remote control is out of range
of the appliance.| Step closer to the appliance and repeat the
action.
The plastic film was not removed
from the battery.| Remove the protective plastic film.
The display shows an error
code “E0”.| The water detector (KB) and
electronics (KB) are disconnected.| Contact your dealer.
The water detector (PDB) is
damaged.| Contact your dealer.
The display shows an error
code “El”.| set The factory setting of the water
detector (PCB) failed.| Follow these steps to reset the device:
1. Switch off the appliance and unplug it from the mains.
2. Remove the water tank.
3. Dry the silver base stand.
4.Plug the appliance into the socket.
5.Press the POWER button twice, then
Press and hold the POWER button again for
2 seconds. ‘Pr and then “PA’ appears on
the display.
6.Unplug the appliance from the mains. The appliance has been reset. The entire process of resetting the appliance must be completed within one minute. If the appliance no longer works, contact your dealer.
The water detector (PDB) is
damaged.| Contact your dealer.
The display shows an error code “Er.| There is too much water in the base.| Switch off the humidifier and unplug it.
Remove the water tank and pour the water out of the base. Check the water tank for leaks. If there is no leak, return the water tank to the appliance.

Instructions for pairing the device

  1. At the beginning of the pairing, you need to be connected to your Wi-Fi-Fi network.
  2.  Before connecting the app to the device, make sure that the Wi-Fi icon on the appliance, which you can press and hold to activate, is flashing.
  3. Next, press “Add device” (Fig. 8) in the app to add a new device and “Add manually” and “Auto scan” (Fig. 9) options will pop up.
  4.  Select the “Auto scan” option and enable the Wi-Fi connection (Fig. 10).
  5. Select your Wi-Fi network to which the device needs to connect to and enter your password (Fig. 10).
  6. This will start the set-up process, which may take some time (Fig. 11).
  7. Your phone will try to connect to the device and it will connect it to your Wi-Fi network (Fig. 11).
  8. Select your device and click “Next” (Fig. 12).
  9. After successful set-up (Fig. 13), click “Done” to enter the device control interface (Fig. 14).

Pairing troubleshooting

  • Check that your Wi-Fi network password is correct.
  •  The device only supports 2.4GHz Wi-Fi networks.
  • The router is overloaded as many other devices are connected.
  • Error while attempting to connect to the device, go back to Fig. 9 and try to manually connect to its Wi-Fi network.

Compatibility:

  • Smart device operating system – Android 5.0 and higher
  • IOS 9.0 and higher
  •  Wi-Fi network -– 2.4 GHz
  •  WPA1 and WPA2 security (WPA2 recommended)

NOTICE: The appliance cannot be operated on IEEE 802.1X-protected Wi-Fi networks (usually corporate Wi-Fi networks).
WIRELESS CONNECTION AND COMPATIBILITY

  •  Jindřich Valenta – CONCEPT shall in no way be liable for any incidental, indirect or consequential damages, or for
    any loss of data or loss due to information leakage during communication via wireless technologies.

  •  Successful wireless communication cannot be 100% guaranteed on all Smart devices and Wi-Fi networks (routers). Due to the variety of devices on the market, there may be cases where the character or specification of a given Smart device or Wi-Fi network (router) makes connection impossible or is somehow disturbed. In addition, a number of factors, including hardware and software configuration, also affect the success of wireless communication via WiFi network. The connection between the appliance and your Wi-Fi network can also be adversely affected by the surrounding Wi-Fi networks, hich can be tuned to the same channel and thus interfere with the connection (e.g. in housing estates,  apartment buildings, etc.). These facts are not a reason to claim the appliance.

  •  The application is owned and operated by a third party (the “Entity”) different from Jindřich Valenta – CONCEPT (the “Seller”). No personal data is transferred to the  ntity by the Seller. When registering for the application, the customer submits personal data directly to the Entity, who becomes the administrator of personal data. The application and the associated protection of personal data are governed by the Entity’s rules.

SERVICE

Extensive maintenance or repair, which requires access to internal parts of the product, has to be performed by a qualified service centre.
ENVIRONMENTAL CONCERNS

  • Packaging materials and old appliances should be recycled.
  •  Packaging materials may be disposed of as sorted waste.
  •  Dispose the plastic bags made of polyethylene (PE) of as sorted waste.

Recycling of the appliance at the end of its lifespan
This appliance is labeled in accordance with European Directive 2012/19/EU concerning used electrical and electronic appliances (Waste Electrical and Electronic Equipment – WEEE). The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead, it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The disposal of such material has to be done according to the recycling regulations. For more detailed information about recycling of this appliance see the authorized local office or service for household waste disposal or the shop, where you purchased the appliance.
The product meets all the necessary requirements of the EU directives applicable to the specific product.
Changes in text, design and technical specifications are subject to change without notice and we reserve the right to change them.

EU Declaration of conformity
Product/model
Type: Air Humidifier ZV2021 SPS-103W  Name and address of
manufacturer: Jindřich Valenta – Concept Vysokomýtská 1800 565 01 Choceň
This declaration of conformity is issued under the sole responsibility of the manufacturer.
The subject of the declaration: The product is intended for households. The product is designed for humidification.
The product described above complies with the relevant harmonization legislation of the European Union:
directive 2014/35/EU (LVD),
directive 2014/30/EU (EMC),
directive 2011/65/EU (RoHS),
directive 2014/53/EU (RED).

Frequency range (MHz) Max. Transmit power (dBm)
2412-2472 MHz ≤ 17,30 dBm

Relevant harmonized standards used:
EN 60335-2-98:2003+A1:2005+A2:2008+A11:2019
EN 60335-1:2012+A11:2014+A13:2017+A1:2019+A14:2019+A2:2019
EN 62233:2008
EN 55014-1:2017
EN 301 489-1 V2.2.3
EN 301 489-17 V3.2.2
EN IEC 61000-3-2:2019
EN 61000-3-3:2013+A1:2019
EN 55014-2:2015
EN 300 328 V2.2.2
EN 62311:2020

Signed and followed by the name:
In: Choceň 8.6.2021
Name and function: Dominik Jehlička, Product engineer SDA Jindřich Valenta – Concept
Vysokomýtská 1800, Choceň Tel.: +420 465 471 400
E-mail:info@my-concept.c

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals