Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- High efficiency up to 94%
- Fanless design, cooling by free air convection
- -55-‘+70°C wide operating range
- Aluminum case and filling with heat-conducted silicone
- IP65 design, optional IP68 rated model available
- Meet 6KV surge immunity level
- Withstand 100 vibration test
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Operating altitude up to 5000 meters (Note.9)
- 6 years warranty
Applications
- Outdoor telecommunication equipment
- Outdoor electronic signage and billboard
- Petroleum plant or mine shaft facility
Description
HEP-185 is a 185W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 94%, enabling HEP-185 perfectly work between -55°C and +70°C under free air convection.
Model Encoding
SPECIFICATION
MODEL| HEP-185-12▢| HEP-185-15▢| HEP-185-24▢|
HEP-185-36▢| HEP-185-48▢| HEP-185-54▢
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 24V| 36V| 48V| 54V
RATED CURRENT| 13A| 11.5A| 7.8A| 5.2A| 3.9A| 3.45A
RATED POWER| 156W| 172W| 187.2W| 187.2W| 187.2W| 186.3W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p| 150mVp-p|
200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE Note.5| 10.8 ~ 13.5V| 13.5 ~ 17V| 22 ~ 27V| 33 ~
40V| 43 ~ 53V| 49 ~ 58V
CURRENT ADJ. RANGE| Can be adjusted by internal potentiometer for A type
only
6.5 ~ 13A| 5.75 ~ 11.5A| 3.9 ~ 7.8A| 2.6 ~ 5.2A| 1.95 ~ 3.9A| 1.72 ~ 3.45A
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±1.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME Note.7| 1000ms,50ms/115VAC 500ms,50ms/230VAC at
full load
HOLD UP TIME (Typ.)| 16ms at full load 230VAC /115VAC
INPUT| VOLTAGE RANGE **Note.4| 85~264VAC (277VAC operational)
120~370VDC(390VDC operational)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at
full load
EFFICIENCY (Typ.)| 91.5%| 92%| 93.5%| 93.5%| 94%| 94%
AC CURRENT**
(Typ.)
| 12V| 1.8A / 115VAC 0.8A / 230VAC 0.7A / 277VAC
15V ~ 54V| 2.1A / 115VAC 1A / 230VAC 0.8A / 277VAC
INRUSH CURRENT(Typ.)| COLD START 65A at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
PROTECTION| OVERLOAD| 105 ~ 125%
Protection type : Constant current limiting, recovers automatically after
fault condition is removed
SHORT CIRCUIT| Constant current limiting, recovers automatically after
fault condition is removed
OVER VOLTAGE| 14 ~ 17V| 18 ~ 21V| 28 ~ 34V| 41 ~ 46V| 54 ~ 63V| 59 ~ 65V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to
recovery
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
ENVIRONMENT
| WORKING TEMP.| -55 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -60 ~ +80℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along
X, Y, Z axes
SAFETY & **EMC**
| SAFETY STANDARDS **Note.6,9| UL62368-1, IEC62368-1, IP65 (or
IP68 for HEP-185 Blank type), EAC TP TC 004 approved ;
Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55024, light industry level (surge 6KV), criteria A, EAC TP TC 020
OTHERS| MTBF| 164.1K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 2286838.8mm (LWH)
PACKING| 1.15Kg; 12pcs/14.8Kg/0.8CUFT
NOTE**| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load
regulation.
4. Derating may be needed under low input voltages. Please check the static
characteristics for more details.
5. A type only.
6. Safety and EMC design refer to BS EN/EN60598-1, CNS15233, GB7000.1, FCC
part18.
7. Length of set up time is measured at cold first start. Turning ON/OFF the
power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in
combination with final equipment. Since EMC performance will be affected by
the complete installation, the final equipment manufacturers must re-qualify
EMC Directive on the complete installation again.
9. The water protection level test for the IP68 rating is performed 1000mm
below the surface of the water for 1 month.
10. The ambient temperature derating of 3.5℃/1000m with fanless models and of
5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
※ IP65 rated. Output voltage and constant current level can be adjusted
through internal potentiometer.