MEAN WELL HEP-150-12A 150W Switching Power Supply for Harsh Environment User Guide

June 8, 2024
MEAN WELL

MEAN WELL HEP-150-12A 150W Switching Power Supply for Harsh Environment User Guide
MEAN WELL HEP-150-12A 150W Switching Power Supply for Harsh
Environment

Features

  • Universal AC input / Full range (up to 305VAC)
  • Built-in active PFC function
  • High efficiency up to 94%
  • Finless design, cooling by free air convection
  • -55~+70℃ wide operating range
  • Aluminum case and filling with heat-conducted silicone
  • IP65 design, optional IP68 rated model available
  • Meet 6KV surge immunity level
  • Withstand 10G vibration test
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Operating altitude up to 5000 meters (Note.9)
  • 6 years warranty
    Features

Applications

  • Outdoor telecommunication equipment
  • Outdoor electronic signage and billboard
  • Petroleum plant or mine shaft facility
    Application

Description

HEP-150 is a 150W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment.
The entire series is housed with the aluminum case and fully potted with heat- conducted silicone.
Thanks to state-of-the-art design, the working efficiency is up to 94%, enabling HEP-150 perfectly work between -55℃ and +70℃ under free air convection.

Model Encoding

Model Encoding

A: Standard model, IP65, Vo and Io level can be adjusted through internal potentiometer.
Blank: Optional model, IP68, with fixed Vo and Io level.

SPECIFICATION

MODEL| HEP-150-12| HEP-150-15| HEP-150-24| HEP-150-36| HEP-150-48| HEP-150-54
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 24V| 36V| 48V| 54V
RATED CURRENT| 12.5A| 10A| 6.3A| 4.2A| 3.2A| 2.8A
RATED POWER| 150W| 150W| 151.2W| 151.2W| 153.6W| 151.2W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE Note.5| 10.8 ~ 13.5V| 13.5 ~ 17V| 22 ~ 27V| 33 ~ 40V| 43 ~ 53V| 49 ~ 58V
CURRENT ADJ. RANGE| Can be adjusted by internal potentiometer for A type only
7.5 ~ 12.5A| 6 ~ 10A| 3.8 ~ 6.3A| 2.5 ~ 4.2A| 1.92 ~ 3.2A| 1.68 ~ 2.8A
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±1.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME Note.7| 1000ms,50ms/115VAC       500ms,50ms/230VAC at full load
HOLD UP TIME (Typ.)| 16ms at full load    230VAC /115VAC
INPUT| VOLTAGE RANGE   Note.4| 85~264VAC (277VAC operational) 120~370VDC(390VDC operational)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
EFFICIENCY (Typ.)| 91.5%| 92%| 93%| 93.5%| 94%| 94%
AC CURRENT (Typ.)| 1.7A / 115VAC         0.75A / 230VAC         0.7A / 277VAC
INRUSH CURRENT(Typ.)| COLD START 65A at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
PROTECTION| OVERLOAD| 105 ~ 125%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Constant current limiting, recovers automatically after fault condition is removed


OVER VOLTAGE

| 14 ~ 17V| 18 ~ 21V| 28 ~ 34V| 41 ~ 46V| 54 ~ 63V| 59 ~ 65V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| -55 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -60 ~ +80℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & **EMC| SAFETY STANDARDS ****Note.6,9| UL62368-1, IEC62368-1,IP65 (or IP68 for HEP-150 Blank type), EAC TP TC 004 approved;
Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC       I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, light industry level (surge 6KV), criteria A, EAC TP TC 020
OTHERS| MTBF| 164.1K hrs min.      MIL-HDBK-217F (25℃)
DIMENSION| 2286838.8mm (LWH)
PACKING| 1.15Kg; 12pcs/14.8Kg/0.8CUFT
NOTE**|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
  5. A type only.
  6. Safety and EMC design refer to BS EN/EN60598-1, CNS15233, GB7000.1, FCC part18.
  7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
  8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
  9. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
  10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer: For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)

Block Diagram

Block Diagram

Derating Curve

AMBIENT TEMPERATURE (℃)
Derating Curve

Static Characteristics

INPUT VOLTAGE (V) 60Hz
Static Characteristics

Mechanical Specification

A Type: HEP-150-_A(standard model)
Mechanical Specification
IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
(Can access by removing the rubber stopper on the case.)

Blank: HEP-150(optional model)
Mechanical Specification

Installation Manual

Please refer to: http://www.meanwell.com/manual.html

User’s Manual
_Scan Me

_

Documents / Resources

| MEAN WELL HEP-150-12A 150W Switching Power Supply for Harsh Environment [pdf] User Guide
HEP-150-12A 150W Switching Power Supply for Harsh Environment, HEP-150-12A, 150W Switching Power Supply for Harsh Environment, Power Supply for Harsh Environment, Harsh Environment
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals