Inovelli Fan & Light Switch LZW36 Manual

June 8, 2024
inovelli

Table of Contents

Inovelli

Fan & Light Switch

SKU: LZW36

Quickstart

This is a
secure
Multilevel Switch
for
.

To run this device please connect it to your mains power supply.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The Inovelli Red Series Fan/Light Switch is a 700 Series Z-Wave in-wall fan + light switch that controls both your fan motor and its attached LED, CFL, & Incandescent bulbs which can be highly customized to your liking at the switch itself with our unique config buttons and advanced firmware. In addition, the Red Series comes with advanced features such as scene support, power monitoring, notifications, local protection, etc. This is the first of its kind that allows homes that only have one wire coming from the fan to the light switch and uses both a light switch and canopy module. Inspired and worked on by our wonderful community.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 5| Lifeline group. Members of this group will receive unsolicited messages related to the status of the switch.
---|---|---
2| 5| Sends On & Off commands to associated devices. (1. Single press UP button sends BasicSet (0xFF) and 2. Single press Down sends BasicSet (0x00)
3| 5| Sends set level commands to associated devices when switch is pressed.(1. Hold & Release Up or Down button sends SwitchMultiLevelSet which keeps associated devices in sync with this device. 2. Single press Up button sends SwitchMultiLevelSet(0xFF) and 4. Single press Down button sends SwitchMultiLevelSet(0x00)
4| 5| Sends start / stop level change to associated devices.(1. Hold Up button sends SW_MULTILEVEL_START_LEVEL_CHANGE (Up)2: Hold Down button sends SW_MULTILEVEL_START_LEVEL_CHANGE (Down) 3. Release Either button sends SW_MULTILEVEL_STOP_LEVEL_CHANGE
5| 5| Sends On & Off commands to associated devices. (1. Single press UP button sends BasicSet (0xFF) and 2. Single press Down sends BasicSet (0x00)
6| 5| Sends set level commands to associated devices when switch is pressed.(1. Hold & Release Up or Down button sends SwitchMultiLevelSet which keeps associated devices in sync with this device. 2. Single press Up button sends SwitchMultiLevelSet(0xFF) and 4. Single press Down button sends SwitchMultiLevelSet(0x00)
7| 5| Sends start / stop level change to associated devices.(1. Hold Up button sends SW_MULTILEVEL_START_LEVEL_CHANGE (Up)2: Hold Down button sends SW_MULTILEVEL_START_LEVEL_CHANGE (Down) 3. Release Either button sends SW_MULTILEVEL_STOP_LEVEL_CHANGE

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Dimming Speed – Light

This changes the speed in which the attached light dims up or down. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed.
Size: 1 Byte, Default Value: 3

SettingDescription

0 – 100 Speed at which light dims up or down (increments)

Parameter 10: Auto Off TimerLight

Automatically turns the light off after this many seconds. When the switch is turned on a timer is started that is the duration of this setting. When the timer expires, the switch is turned off.
Size: 2 Byte, Default Value: 0

SettingDescription

0 Disabled
1 – 32767 Seconds

Parameter 11: Auto Off TimerFan

Automatically turns the fan off after this many seconds. When the fan is turned on a timer is started that is the duration of this setting. When the timer expires, the fan is turned off.
Size: 2 Byte, Default Value: 0

SettingDescription

0 Disabled
1 – 32767 Seconds

Parameter 12: Default Level (Local)Light

Default level for the dimmer when it is powered on from the local switch. A setting of 0 means that the switch will return to the level that it was on before it was turned off.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Sets back to light level prior to switch turning off
1 – 99 Sets light to a certain default dim level (ie: 1-99%) when powered on

Parameter 13: Default Level (Z-Wave)Light

Default level for the dimmer when it is powered on from a Z-Wave command. A setting of 0 means that the switch will return to the level that it was on before it was turned off.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Sets back to light level prior to switch turning off – via Z-Wave Command
1 – 99 Sets light to a certain default dim level (ie: 1-99%) when powered on

– via Z-Wave Command

Parameter 14: Default Level (Local)Fan

Default level for the fan when it is powered on from the local switch. A setting of 0 means that the switch will return to the level that it was on before it was turned off
Size: 1 Byte, Default Value: 0

SettingDescription

0 Sets back to fan level prior to switch turning off
1 – 99 Sets fan to a certain default dim level (ie: 1-99%) when powered on

Parameter 15: Default Level (Z-Wave)Fan

Default level for the fan when it is powered on from a Z-Wave command. A setting of 0 means that the switch will return to the level that it was on before it was turned off.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Sets back to fan level prior to switch turning off – Z-Wave
1 – 99 Sets fan to a certain default dim level (ie: 1-99%) when powered on –

Z-Wave

Parameter 16: State After Power Restored Light

The state the switch should return to once power is restored after power failure. 0 = off, 1-99 = level, 100=previous
Size: 1 Byte, Default Value: 100

SettingDescription

0 Off
1 – 99 Turns on to a certain percentage (1-99%)
100 Returns to previous state the light was in prior to a power outage

Parameter 17: State After Power Restored Fan

The state the switch should return to once power is restored after power failure. 0 = off, 1-99 = level, 100=previous.
Size: 1 Byte, Default Value: 0

SettingDescription

0 Off
1 – 99 Turns on to a certain percentage (1-99%)
100 Returns to previous state the fan was in prior to power outage

Parameter 18: Default LED Strip ColorLight

This is the color of the Light LED strip represented as part of the HUE color wheel. Since the wheel has 360 values and this parameter only has 255, the following equation can be used to determine the color: value/255 * 350 = Hue color wheel value
Size: 1 Byte, Default Value: 170

SettingDescription

0 – 255 Color values

Parameter 19: Default LED Strip IntensityLight

This is the intensity of the LED strip.
Size: 1 Byte, Default Value: 5

SettingDescription

0 – 9 Intensity of the LED strip

Parameter 2: Dimming Speed (From Switch) – Light

This changes the speed in which the attached light dims up or down when controlled from the physical switch. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 99 should keep this in sync with parameter 1.
Size: 1 Byte, Default Value: 99

SettingDescription

0 – 98 Speed at which light dims up and down (from switch)
99 Sync to Parameter 1

Parameter 20: Default LED Strip ColorFan

This is the color of the Fan LED strip represented as part of the HUE color wheel. Since the wheel has 360 values and this parameter only has 255, the following equation can be used to determine the color: value/255 * 350 = Hue color wheel value
Size: 1 Byte, Default Value: 170

SettingDescription

0 – 255 Color values

Parameter 21: Default LED Strip Intensity Fan

This is the intensity of the fan LED strip.
Size: 1 Byte, Default Value: 5

SettingDescription

0 – 9 Intensity of the Fan LED strip

Parameter 22: Default LED Strip Intensity (When OFF)Light

This is the intensity of the Light LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off.
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 9 Intensity of the Light LED strip (when lights are off)

Parameter 23: Default LED Strip Intensity (When OFF)Fan

This is the intensity of the Fan LED strip when the switch is off. This is useful for users to see the light switch location when the lights are off.
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 9 Intensity of the Fan LED strip (when fan is off)

Parameter 24: LED Strip EffectLight

This will allow you to add some sweet effects to your LED Bar (i.e.: pulse, chase, solid, etc). Byte 1 = Color, Byte 2 = Brightness Level, Byte 3 = Effect, Byte 4 = Duration. *Please see website for further instructions on how to set this up
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 4294967295| Please see website instructions to set this up: https://nathanfiscus.github.io/inovelli-notification-calc/
---|---

Parameter 25: LED Strip EffectFan

This will allow you to add some sweet effects to your LED Bar (i.e.: pulse, chase, solid, etc). Byte 1 = Color, Byte 2 = Brightness Level, Byte 3 = Effect, Byte 4 = Duration. *Please see website for further instructions on how to set this up
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 4294967295| Please see website instructions to set this up: https://nathanfiscus.github.io/inovelli-notification-calc/
---|---

Parameter 26: Timeout for LED BarLight

When the LED strip is disabled (Light LED Strip Intensity is set to 0), this setting allows the LED strip to turn on temporarily while being adjusted.
Size: 1 Byte, Default Value: 3

SettingDescription

0 Disabled
1 – 10 Intensity level

Parameter 27: Name: Timeout for LED BarFan

When the LED strip is disabled (Fan LED Strip Intensity is set to 0), this setting allows the LED strip to turn on temporarily while being adjusted.
Size: 1 Byte, Default Value: 3

SettingDescription

0 Disabled
1 – 10 Intensity Level

Parameter 28: Active Power Reports

The power level change that will result in a new power report being sent. The value is a percentage of the previous report. 0 = disabled.
Size: 1 Byte, Default Value: 10

SettingDescription

0 Disabled
1 – 100 Percentage of the previous report

Parameter 29: Periodic Power & Energy Reports

Time period between consecutive power & energy reports being sent (in seconds). The timer is reset after each report is sent
Size: 2 Byte, Default Value: 3600

SettingDescription

0 Disabled
1 – 32767 Seconds

Parameter 3: Ramp Rate

This changes the speed in which the attached light turns on or off. For example, when a user sends the switch a basicSet(value: 0xFF) or basicSet(value: 0x00), this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 99 should keep this in sync with parameter 1.
Size: 1 Byte, Default Value: 99

SettingDescription

1 – 98 Speed at which the light turns on and off
99 Sync to Parameter 1

Parameter 30: Energy Reports

Energy level change which will result in sending a new energy report. Available settings: 1-127 (0.01-1.27 kWh) 0 = disabled.
Size: 1 Byte, Default Value: 10

SettingDescription

0 Disabled
1 – 100 Percentage of the previous report

Parameter 4: Ramp Rate (From Switch)

This changes the speed in which the attached light turns on or off from the physical switch. For example, when a user presses the up or down button, this is the speed in which those actions take place. A setting of 0 should turn the light immediately on or off (almost like an on/off switch). Increasing the value should slow down the transition speed. A setting of 99 should keep this in sync with parameter 1.
Size: 1 Byte, Default Value: 99

SettingDescription

0 – 98 Speed at which the light turns on and off (from switch)
99 Sync to Parameter 1

Parameter 5: Minimum LevelLight

The minimum level that the dimmer allows the bulb to be dimmed to. Useful when the user has a bulb that does not turn on at a lower level.
Size: 1 Byte, Default Value: 1

SettingDescription

1 – 45 Minimum % level the bulb can be dimmed down to

Parameter 6: Maximum LevelLight

The maximum level that the dimmer allows the bulb to be dimmed to. Useful when the user has an LED bulb that reaches its maximum level before the dimmer value of 99.
Size: 1 Byte, Default Value: 99

SettingDescription

55 – 99 Maximum % level the bulb can be dimmed up to

Parameter 7: Minimum LevelFan

The minimum level that the dimmer allows the fan to be dimmed to. Useful when the user has a fan that does not turn on at a lower level.
Size: 1 Byte, Default Value: 1

SettingDescription

1 – 45 Minimum % level the fan can be dimmed down to

Parameter 8: Name: Maximum LevelFan

The maximum level that the dimmer allows the fan to be dimmed to.
Size: 1 Byte, Default Value: 99

SettingDescription

55 – 99 Maximum % level the fan can be dimmed up to

Parameter 9: Invert Switch

Inverts the switch (Tap Down = On, Tap Up = Off). 0 = Disabled, 1 = Enabled
Size: 1 Byte, Default Value: 0

SettingDescription

0 Disabled
1 Enabled

Technical Data

Hardware Platform ZGM130
Device Type Multilevel Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.27
Z-Wave Version 7.13.4
Certification ID ZC12-20060074
Z-Wave Product Id 0x031E.0x000E.0x0001
Electric Load Type Dimmable LEDInductive (e.g. Motor)
Neutral Wire Required ok
Color White
Switch Type Decorator Paddle Push
Z-Wave Scene Type Central Scene
Firmware Updatable Updatable by Manufacturer
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Application Status
  • Association Grp Info V3
  • Association V2
  • Basic V2
  • Central Scene V3
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Meter V3
  • Multi Channel Association V3
  • Multi Channel V4
  • Powerlevel
  • Protection V2
  • Security
  • Security 2
  • Supervision
  • Switch Multilevel V4
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic V2
  • Switch Multilevel V4

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals