HYUNDAI 55011 Inverter Gasoline Generator Instruction Manual

June 8, 2024
HYUNDAI

HYUNDAI 55011 Inverter Gasoline Generator

HYUNDAI-55011-Inverter-Gasoline-Generator-PRODUCT

WARNING
Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.

SAFETY WARNINGS

When using the machine, always observe the enclosed safety warnings as well as additional safety warnings.
The following symbols are used throughout this manual and/or on the machine:

  • Denotes risk of personal injury or damage to the machine.
  • Denotes important information regarding the use of the machine.
  • Read the manual and instructions.
  • Wear hearing protection.
  • Do not use the machine in surroundings where sparks, flames or open fire can be present. Do not smoke near the machine.
  • Do not expose the machine to rain or wet conditions (moisture).
  • ONLY operate the machine outdoors in well-ventilated areas.
  • Before use, always earth the machine!

ADDITIONAL SAFETY WARNINGS FOR GENERATORS

Work area safety

  • Place the machine on a solid surface. Do not place the machine on a metal surface.
  • Do not store fuel near the machine.

Electrical safety

  • Before use check whether the power input of the equipment to be connected is less than the maximum output of the generator.
  • Only connect the equipment when the generator is running at full speed. Disconnect the equipment before switching off the generator.

Personal safety

  • Avoid touching hot parts of the machine.
  • Never add fuel when the machine is running. After use let the machine cool down for at least 15 minutes before refuelling.

Power tool use and care

  • Do not use the machine for feeding electrical appliances (as an external power source).
  • Do not place the machine in the blazing sun. Do not expose the machine to temperatures over 40°C. Do not store the machine in humid surroundings.
  • Make sure that the generator has enough fuel when connected to the load.
  • The sound absorber and the air filter function as flame catchers in case of after-burning. Therefore see to it that they are mounted properly and are in good technical condition.
  • Immediately switch off the generator in one of the following situations:
    • hitches or unstable running of the motor
    • decrease of the electrical output
    • overheating of the connected load
    • excessive vibrating of the generator
    • sparking
    • presence of smoke or fire

DESCRIPTION (FIG. A, B)

HYUNDAI-55011-Inverter-Gasoline-Generator-FIG1 HYUNDAI-55011-Inverter-Gasoline-Generator-FIG2

These generator is designed for generating electricity to feed electrical machines or devices. The machine is not supplied with oil and fuel.

  1. Choke
  2. Fuel cap vent lever
  3. Fuel cap
  4. Air filter cover
  5. Starter cord
  6. Ignition switch
  7. Control panel
  8. Spark plug cover
  9. Muffler
  10. Economy switch
  11. Hour meter
    • RESET button
  12. Output indicator
  13. Overload indicator
  14. Oil alarm indicator
  15. AC socket (230 V/50 Hz)
  16. DC circuit protection
  17. 12 V DC input
  18. Earth connector

Package contents

  • Inverter generator
  • Spark plug wrench
  • Instructions
  • Safety instructions
  • Warranty and service conditions

ECONOMY SWITCH (FIG. A, B, C)

HYUNDAI-55011-Inverter-Gasoline-Generator-FIG1 HYUNDAI-55011-Inverter-Gasoline-Generator-FIG2

The economy switch (10) ensures lower fuel consumption. With the economy switch switched on, the motor runs slowly when the connected device is disconnected and automatically returns to the correct speed when the electrical device is reconnected. Disable the economy function when using the DC connection and when using DC and AC simultaneously. With the economy switch in the OFF position, the motor rotates at high speed.

Hour meter (fig. A, B)
The voltage> frequency> speed> total operating time is displayed in succession on the hour meter (11). If the overload indicator (13) illuminates red, the output of the generator can be reactivated with the RESET button (11a) without restarting the motor.

  • Press and hold the RESET button for 1 second until the overload indicator turns off and the output indicator (12) turns green.

After pressing the RESET button 5 times, the motor must be restarted.

BEFORE FIRST USE

Fill with oil (fig. D)
Use 4-stroke motor oil. SAE 10W-30 is recommended for general, all-temperature use. Other viscosities may be used when the average temperature is within the indicated range.

  1. Remove the dipstick (19) from the filling point.
  2. Fill the crankcase with the prescribed amount of oil.
  3. Replace the dipstick.

Fill with fuel (fig. F)
Always use fuel that fulfils the following specifications: unleaded petrol, octane content at least 87.

WARNING

Never add fuel when the machine is on. After use let the machine cool down for at least 15 minutes before refuelling. Never smoke near the machine or the fuel. Never add fuel in the vicinity of sparks, flames or open fire.

  1. Remove the lid (3) from the filler opening.
  2. Pour the fuel carefully into the filler opening. Do not fill the tank beyond the marking.
  3. Place the lid back on the filler opening.

USE

The generator must be earthed before use. This prevents static charges that can lead to electric shock. Safety devices from the connected electrical appliances can also do their work (e.g. leakage current switches). Connect a screened conductor (minimum cross-section 1.5 mm²) to the earth connector (18) and attach the other end to a ground point (e.g. radiator or water pipe).

Starting the motor (fig. A, B, G)HYUNDAI-55011-Inverter-Gasoline-
Generator-FIG1 HYUNDAI-55011-Inverter-Gasoline-
Generator-FIG2

HYUNDAI-55011-Inverter-Gasoline-Generator-FIG7

WARNING

Disconnect all connected devices before starting the engine. For the first use, refilling the tank or after prolonged storage, the ignition switch must first be turned to the ON position for 10 to 20 seconds and then pull the starter cord 10-20 times to fill the carburetor with fuel.

  1. Turn the fuel cap vent lever (2) to the ON position.
    During transport of the machine, the fuel cap vent lever must be in the OFF position..

  2. Turn the key of the ignition switch (6) to the ON position.

  3. Slide (55010) or pull (55011) the choke lever to the CLOSED position.
    Do not move the choke lever to the CLOSED position when the engine is hot or in a high ambient temperature.

  4. Gently pull the starter cord (5) until you feel resistance.

  5. Give a strong pull to the starter cord. Repeat as necessary until the engine starts.

  6. Slide (55010) or push (55011) back the choke.

Switch off

Disconnect all connected devices.

  1. Turn the ignition switch (6) to the OFF position.
  2. Turn the fuel cap vent lever (2) to the OFF position.

Modification to the carburetor when used at high altitude
When used at high altitudes, the standard air-fuel mixture may be too rich. Performance will decrease and fuel consumption will increase. A very rich mixture will also pollute the spark plug and cause a hard start. If the generator is used at high altitudes, the main nozzle must be replaced or the idle screw must be adjusted. If the generator is always used at high altitudes, the carburetor must be adjusted. Please contact your purchase address.

WARNING

If the carburetor has been modified for high altitude use, the air-fuel mixture will be too low for use at low altitudes, causing the engine to overheat and become severely damaged. The carburetor must first be returned to its original state.

DIRECTIONS FOR USE

Direct current (DC) (fig. A, B, H)HYUNDAI-55011-Inverter-Gasoline-
Generator-FIG1 HYUNDAI-55011-Inverter-Gasoline-
Generator-FIG2

HYUNDAI-55011-Inverter-Gasoline-Generator-FIG8

The DC input (17) may only be used to charge a 12V battery.

  1. Set the economy switch to the OFF position.
  2. Connect the charging cable to the battery and then to the DC input (17).

Risk of short circuit or sparks! Always connect the charging cable to the battery first. Always disconnect the cable from the generator.

  • If the cable is connected to a battery in a vehicle, the earth cable must first be disconnected from the battery to prevent short circuits.
  • Do not start the engine of the vehicle as long as the generator is connected to the battery. This causes damage to the generator.
  • Connect the positive terminal to the positive pole of the battery.

An incorrect connection can seriously damage the generator and battery.

WARNING

If the battery liquid comes into contact with the skin, immediately rinse the skin with running water. Neutralize with a mild acid, e.g lemon juice or vinegar. In case of contact with the eyes, rinse the eyes with clean running water for at least 10 minutes and consult a doctor.

DC circuit protection (fig. A, B, I)

HYUNDAI-55011-Inverter-Gasoline-Generator-FIG1 HYUNDAI-55011-Inverter-Gasoline-Generator-FIG2HYUNDAI-55011-Inverter-Gasoline-Generator-
FIG9
Disconnect the battery when the DC circuit protection (16) is activated. Wait a few minutes, press the circuit protection again and reconnect the battery.
Alternating current (AC) (fig. A, B, J)HYUNDAI-55011-Inverter-Gasoline-
Generator-FIG1 HYUNDAI-55011-Inverter-Gasoline-
Generator-FIG2
Start the engine as described above. Check that the output indicator (12) is green. To connect an electrical device or machine, plug the mains plug into an AC socket (15).
Overload protection (fig. A, B, J)
The overload protection (13) interrupts the circuit in case of overload or short circuit of an output. Wait at least 1 minute before operating the reset switch (11a). Alternating current can be used simultaneously with direct current. If both are used at the same time, the total power for AC and DC must not be exceeded: AC: 0.9 kVA, DC: 5 A. Most engines require more than their nominal power when starting.
Output and overload indicator (fig. A, B, J)
During normal operation, the output indicator (12) lights up green. If the generator is overloaded (more than 0.9 kVA). or the connected device causes a short circuit, the green indicator turns off and the red overload indicator (13) lights up. The alternating current is switched off, but the motor continues to run.

Oil alarm system (fig. A, B)
The oil alarm system is designed to prevent damage to the engine due to low oil level. The engine is automatically shut down as soon as the oil level becomes too low.

  • The oil alarm indicator (14) lights up red.
  • Check the oil level when the engine stops and does not restart.

CLEANING AND MAINTENANCE

For good functioning and a long lifespan for the machine, regular cleaning and maintenance is essential.

WORKING

Do not perform any cleaning or maintaining activities while the motor is running. Do not smoke during the below work. Do no work in the vicinity of sparks, flames or open fire.

  • Regularly clean the ventilation slots.

Changing the oil (fig. K)
The oil must be changed after the first 20 operating hours, and then after every 100 hours or 6 months.

  1. Place a receiving bin under the bleeding point (19a).
  2. Remove the dipstick (19) from the filling-point.
  3. Remove the screw from the bleeding point.
  4. Tilt the machine slightly remove all oil.
  5. Re-insert the screw and tighten it securely.
  6. Fill the crankcase with the prescribed amount of oil.
  7. Replace the dipstick.

Checking the oil level (fig. D)
Always check the oil level before starting the motor.

  1. Remove the dipstick (19 ) from the filling-point.
  2. Clean the dipstick.
  3. Insert the dipstick into the filling hole for a few seconds before pulling it out again.
  4. Check the oil-level. The oil level should be at a rate between high and low.
  5. If the level is below this mark, refill the oil.
    • Use a funnel to avoid spilling.
    • For easy filling, tilt the machine slightly backward.
  6. Mount the dipstick.

Cleaning the air filter (fig. L)HYUNDAI-55011-Inverter-Gasoline-
Generator-FIG12
You must clean the air filter every 50 operating hours.

  1. Loosen the fastening screw (20).
  2. Remove the cover (4).
  3. Remove the air filter (21) from the filter holder (22).
  4. Clean the filter with spirit or ethanol.
  5. Squeeze the filter. Do not wringe!
  6. Immerse the filter in clean engine oil.
  7. Squeeze the filter and mount it in place.
  8. Reinstall the filter holder.
  9. Reinstall the cover.

Checking the spark plug (fig. N)HYUNDAI-55011-Inverter-Gasoline-
Generator-FIG14

  1. Remove the spark plug cover (8).
  2. Remove the spark plug cable from the spark plug.
  3. Remove the spark plug with the spark plug wrench.
  4. Clean the electrode with a wire brush.
  5. Check the contact distance (correct value 0.6 – 0.7 mm), and adjust if necessary.
  6. Reinstall the spark plug and the spark plug cover.

Maintenance of the spark arrester (fig. M)HYUNDAI-55011-Inverter-
Gasoline-Generator-FIG13
The spark arrester must be cleaned every 100 operating hours.

  1. Remove the screws, and remover the muffler guard.
  2. Remove the spark arrester.
  3. Clean the spark arrester with a steel brush.
  4. Replace the spark plug and mount the muffler guard.

TRANSPORT AND STORAGE

If the machine is out of use for a longer period of time, the fuel tank must be emptied and the oil must be changed. This prevents problems with restarting.

  • Empty the fuel tank.
  • Change the oil.
  • Cover the machine and place it in a clean and dry environment.

Cleaning
Always try to use your generator in a cool dry place. However, in the event your generator becomes dirty you may clean the exterior with one or more of the following:

  • a damp cloth
  • a soft brush
  • a vacuum
  • pressurized air

Never clean your generator with a bucket of water or a hose. Water can get inside the working pats of the generator and cause a short circuit or corrosion.

MAINTENANCE CHART
Regular maintenance is most important for the best performance and safe operation. Never perform maintenance work while the generator is running

 | ****

Action

| ****

Any use

| Every month or 10 hours| Every 3 months or 50 hours| Every 6 months

or 100 hours

| Every 12

months or 300 hours

---|---|---|---|---|---|---
Spark plug| Check distance of electrode and clean, replace if necessary|  |  | ×|  |
Engine oil| Check level| ×|  |  |  |
Replace|  | ×|  |  |
Airfilter| Check| ×|  |  |  |
Clean, replace if necessary|  |  | ×|  |
Fuel filter| Clean, replace if necessary|  |  |  | ×|
Fuel cock| Clean and adjust when engine is cold|  |  |  |  | ×
Fuel line| Check fuel hose for crack or damage, replace if necessary| ×|  |  | |


Exhaust system

| Check for leakage, retighten or replace gasket if necessary| ×|  |  |  |
Check muffler screen, clean / replace if necessary|  |  |  | ×|
Carburator| Check choke operation| ×|  |  |  |
Cooling system| Check fan damage|  |  |  |  | ×
Starting system| Check recoil starter operation| ×|  |  |  |
Decarbonization| As often as necessary|  |  |  |  | ×
Fittings / fasteners| Check all fittings and fasteners|  |  |  | ×|

TECHNICAL DATA

55010

  • Level of sound pressure at the workplace.

55011

  • Level of sound pressure at the workplace.

Subject to change. Specifications can be changed without prior notice.

GUARANTEE
Refer to the enclosed guarantee conditions for the terms and conditions of the guarantee.

ENVIRONMENT
Your product, accessories and packaging should be sorted for environmental- friendly recycling.
Only for EC countries
Do not dispose of power tools into domestic waste. According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment and its implementation into national right, power tools that are no longer usable must be collected separately and disposed of in an environmentally friendly way.

DECLARATION OF CONFORMITY

ART. NR. HYUNDAI 55010 / HY1000Si
ART. NR. HYUNDAI 55011 / HY2000i

Inverter gasoline generator

Dvize bv declares under its sole responsibility that this product is in conformity with the following standards or standardization documents:

EN 12601:2010, EN 61000-6-2:2005, EN 61000-6-4:2007

According to the provisions of the directives:

2006/42/EC, LVD 2006/95EC & 2014/35/EU, ECD 2004/108/EC & 2014/30/EU, 2000/14/EC amended 2005/88/EC

Testing authority:

TÜV Rheinland LGA Products GmbH, Nürnberg, Germany

Keeper of the technical documentation:

Dvize bv
PO Box 150, 1910AD Uitgeest, The Netherlands
service@dvize.eu, www.hyundaipowerproducts.nl

Dvize bv
P O Box 150
1910AD Uitgeest
The Netherlands
service@dvize.eu
www.hyundaipowerproducts.nl

Imported/Distributed by Dvize bv, The Netherlands Licensed by Hyundai Corporation Holdings, Korea

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals