FIBARO Blind Control Insert FIB_FGR-221 Manual
- June 8, 2024
- FIBARO
Table of Contents
- Fibaro Group
- Blind Control Insert
- SKU: FIB_FGR-221
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Fibaro Group
Blind Control Insert
SKU: FIB_FGR-221
Quickstart
This is a ****
Window Control
for
Europe.
To run this device please connect it to your mains power supply.
To include the device into the network, turn the controller into the inclusion mode and then press the Up or Down button of the device three times during 1.5 seconds. The LED will become green for 3 seconds and then turn off. The device is now ready to work.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The Fibar Insert Motor Control allows controlling motors for jalousies and blinds both via Z-Wave wirelessly and locally utilizing a traditional wall switch. The device is placed in a wall box right behind the normal switch. The switch is not longer directly connected to the load but acts as input device for the Fibar insert that is controlling the load. The solution works with all switch design with or without neutral position as long as there is enough space in the wall box behind the switch. The device is just 15 mm height. The available space depends on the size of the traditional switch, the dimensions of the wall box and the amount of additional cabling placed in this box. This device is designed for a 3 wire system and needs a neutral wire in the wall box.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Installation
The motor control insert is designed to fit into standard circular European wall boxes with 60 mm diameter. With its 15 mm height, it can be also mounted behind traditional wall switches. This wall switch serves as an external control switch to controll loads. The relays are realized in the insert.
The inserts contacts N and L are connected directly with the mains distribution of the power network. The three wires of the motor are connected like shown in the figure below.
The motor control can be operated locally using a switching paddle installed on the wall box. To connect the switching paddle with the insert it has to be connected with the insert contacts S1, S2 and Sx. Attention: There must not be mains-power connected to the insert contacts. This would immediately lead to a destruction of the insert..
The local operation can be realized by a double switching paddle (bistable) or a double button (monostable). The connected switch type must be selected according to the inclusion by setting the configuration parameter 14. The local switch is connected with the motor control insert as shown in the schematics. If a bistable switch is connected it has to stay connected until the motor control insert is included into the Z-Wave network.
Attention: The switch insert has an automatic endposition identification. This requires that the insert is connected with a tube motor with endposition switches. A test operation without motor leads to a wrong behavior.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Blinking red/green LED indicates that the device is in factory reset state. Once the controller is turned into inclusion mode tripple click one of the buttons on the device will include the device. A green blinking of LED will indicate successfull inclusion that will be turned off shortly afterwards. The device is excluded by tripple click to one of the buttons when the controller is in exclusion mode.
Exclusion
Blinking red/green LED indicates that the device is in factory reset state. Once the controller is turned into inclusion mode tripple click one of the buttons on the device will include the device. A green blinking of LED will indicate successfull inclusion that will be turned off shortly afterwards. The device is excluded by tripple click to one of the buttons when the controller is in exclusion mode.
Product Usage
The shutter control insert allows you to control 230 V tubular motors. The actuator can directly be operated by the local switching paddle. If the switch is a conventional button, every button impulse will switch the device on or off. Using a switching paddle instead of a button the operation is the same with the exception that the switching paddle has to be switched back into the OFF status afterwards manually. One switching paddle of the double switch drives the motor in the one and the other paddle in the other end position.
The device is also able to report status changes to a controller (communication pattern 2) and to remotely operate other devices (communication pattern 5). The dimmer can be controlled by every Z-Wave device (communication pattern 1, 4 and 7). To operate other devices a second switch which does not operate the dimmer is needed.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
3| 1|
---|---|---
2| 16| external Switch No 2
1| 16| external Switch No 1
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: All on/off function
Enables or disabled the all on / all off function
Size: 1 Byte, Default Value: ff
SettingDescription
00 | neither ALL ON nor ALL OFF are active |
---|---|
01 | only ALL OFF is active |
02 | only ALL ON is active |
ff | ALL ON and ALL OFF are active |
Parameter 10: Turn Off Roller position function
activates the turn off roller positioning function
Size: 1 Byte, Default Value: 00
SettingDescription
00 | enabled |
---|---|
01 | disabled |
Parameter 14: Type of Switch
Defines the type of switch attached to the device
Size: 1 Byte, Default Value: 00
SettingDescription
00 | mono-stable switch |
---|---|
01 | bi-stable switch |
Parameter 20: Favorite position state
defines the favorite position of the blind
Size: 1 Byte, Default Value: 16
SettingDescription
Parameter 30: General Alarm Set
This defines the behavior in case of general alarms
Size: 1 Byte, Default Value: 03
SettingDescription
00 | Deactivated, devices does not react to alarms |
---|---|
01 | Blind will go down in case of alarm |
02 | Blind will go up in case of alarm |
Parameter 31: Flood Alarm Set
This defines the behavior in case of flood alarms
Size: 1 Byte, Default Value: 02
SettingDescription
00 | Deactivated, devices does not react to alarms |
---|---|
01 | Blind will go down in case of alarm |
02 | Blind will go up in case of alarm |
Parameter 32: Smoke Alarm Set
This defines the behavior in case of smoke alarms
Size: 1 Byte, Default Value: 03
SettingDescription
00 | Deactivated, devices does not react to alarms |
---|---|
01 | Blind will go down in case of alarm |
02 | Blind will go up in case of alarm |
Parameter 33: Temperature Alarm Set
This defines the behavior of in case of temperature alarms
Size: 1 Byte, Default Value: 01
SettingDescription
00 | Deactivated, devices does not react to alarms |
---|---|
01 | Blind will go down in case of alarm |
02 | Blind will go up in case of alarm |
Technical Data
Dimensions | 0.0420000×0.0370000×0.0160000 mm |
---|---|
Weight | 26 gr |
Hardware Platform | ZM3102 |
EAN | 5902020528036 |
Device Type | Window Covering No Position/Endpoint |
Generic Device Class | Multilevel Switch |
Specific Device Class | Multiposition Motor Switch |
Firmware Version | 01.03 |
Z-Wave Version | 03.14 |
Certification ID | ZC08-11080006 |
Z-Wave Product Id | 010f.0300.0103 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Basic
- Configuration
- Switch Multilevel
- Version
- Switch All
- Multi Channel Association
- Basic Window Covering
- Manufacturer Specific
- Powerlevel
- Association
- Switch Binary
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>