FIBARO Roller Shutter 4 FIBEFGR-224 Manual
- June 1, 2024
- FIBARO
Table of Contents
- FIBARO
- FIBARO Roller Shutter 4
- SKU: FIBEFGR-224
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 20: Switch type
- Parameter 24: Buttons orientation
- Parameter 25: Outputs orientation
- Parameter 40: First button – scenes sent
- Parameter 41: Second button – scenes sent
- Parameter 150: Calibration
- Parameter 151: Operating mode
- Parameter 152: Venetian blind – slats full turn time
- Parameter 156: Time of up movement
- Parameter 157: Time of down movement
- Parameter 158: Virtual limit switch. The pot protection
- Parameter 159: Favorite position – opening level
- Parameter 160: Favorite position – slat angle
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FIBARO
FIBARO Roller Shutter 4
SKU: FIBEFGR-224
Quickstart
This is a
secure
Window Control (endpoint aware)
for
Europe.
To run this device please connect it to your mains power supply.
SmartStart enabled products can be added into a Z-Wave network by scanning the
Z-Wave QR Code present on the product with a controller providing SmartStart
inclusion. SmartStart product will be added automatically within 10 minutes of
being switched on in the network range.
To add the device to the Z-Wave network using SmartStart:
1. To use SmartStart your controller needs to support Security S2 (see the
controller’s manual).
2. Enter the full DSK string code to your controller. If your controller is
capable of QR scanning, scan the QR code placed on the label on the bottom of
the box.
3. Power the device (turn on the mains voltage).
4. LED will start blinking yellow, wait for the adding process to end.
5. Successful adding will be confirmed by the Z-Wave controller’s message
and the device’s LED indicator:
• Green – successful (non-secure, S0, S2 non-authenticated),
• Magenta – successful (Security S2 Authenticated),
• Red – not successful.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The FIBARO Roller Shutter 4 – equipped with the Z-Wave 800 chip – is a device designed to control roller shutters, awnings, blinds, curtains and pergolas. The roller shutter enables precise positioning of roller shutters or blind slits. The device is equipped with energy monitoring. It enables the control of connected devices either via the Z-Wave network or a directly connected switch. FIBARO focussed on easy installation and an intuitive initial design. There are more inputs for N and L cables, so there is no need to use connection terminals. The shape and dimensions of the device allow easy and quick installation in flush-mounted boxes. The button and diode are easily accessible. Equipped with plug-in connectors, it enables even faster installation – no screwdriver required. Three extra connection cables for connecting the switch are included. The integrated bridge provides a simple bridging option for phase and neutral. It is not necessary to use Wago connectors to connect wires. You save space in the box and reduce installation time thanks to the push-in wire connection.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
1. Switch off the mains voltage (disable the fuse).
2. Remove the device from the wall switch box.
3. Switch on the mains voltage.
4. Press and hold the PROG button to enter the menu.
5. Wait for the LED indicator to glow yellow.
6. Quickly release and click the PROG button again.
7. During the factory reset, the LED indicator will blink yellow.
8. After few seconds the device will be restarted, which is signalled with
the red LED indicator colour.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Installation
1. Switch off the mains voltage (disable the fuse).
2. Open the wall switch box.
3. Connect with the following diagram.
4. Verify if the device is connected correctly.
5. Arrange the device in a wall switch box.
6. Close the wall switch box.
7. Switch on the mains voltage.
Legend:
L… Life
N…Neutral
S1… Switch 1
S2… Switch 2
O1… Output 1
O2… Output 2 ”
Switch Configuration Monostable switches – click to move
– Parameter 20 value 0
– Roller blind, Awning, Pergola or Curtain – Parameter 151 Value 0
– Venetian blind – Parameter 151 value 1 or 2
Favorite position – available
Monostable switches – hold to move
– Parameter 20 value 1
– Roller blind, Awning, Pergola or Curtain – Parameter 151 Value 0
– Venetian blind – Parameter 151 value 1 or 2
Favorite position – available
If you hold down the switch longer than slats movement time + additional 4
seconds (default 1,5s+4s =5,5s) the device will go limit position. In that
case releasing the switch will do nothing.  
Single monostable switch
– Parameter 20 value 2
– Roller blind, Awning, Pergola or Curtain – Parameter 151 Value 0
– Venetian blind – Parameter 151 value 1 or 2
Favorite position – available
Bistabile switches
– Parameter 20 value 3
– Roller blind, Awning, Pergola or Curtain – Parameter 151 Value 0
– Venetian blind – Parameter 151 value 1 or 2
” Favorite position – unavailable
Single bistabile switch
– Parameter 20 value 4
– Roller blind, Awning, Pergola or Curtain – Parameter 151 Value 0
– Venetian blind – Parameter 151 value 1 or 2
Favorite position – unavailable
Three-state switch
– Parameter 20 value 5
– Roller blind, Awning, Pergola or Curtain – Parameter 151 Value 0
– Venetian blind – Parameter 151 value 1 or 2
Favorite position – unavailable
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
1. Power the device.
2. Identify the PROG button or the S1/S2 switches.
3. Set the main controller in (Security/non-Security Mode) add” mode (see the
controller’s manual).
4. Quickly, click PROG button three times. Optionally, click S1 or S2 three
times.
5. If you are adding in Security S2 Authenticated, input the PIN Code (label
on the device, also underlined part of the DSK on the label on the bottom of
the box).
6. Wait for the LED indicator to blink yellow.
7. Successful adding will be confirmed by the Z-Wave controller’s message
and the device’s LED indicator:
• Green – successful (non-secure, S0, S2 non-authenticated),
• Magenta – successful (Security S2 Authenticated),
• Red – not successful
Exclusion
1. Make sure the device is powered.
2. Identify the PROG button or the S1/S2 switches.
3. Set the main controller in remove mode (see the controller’s manual).
4. Quickly, click PROG button three times. Optionally, click S1 or S2 three
times within 10 minutes of powering up the device.
5. Wait for the removing process to end.
6. Successful removing will be confirmed by the Z-Wave controller’s message
and the device’s LED indicator – Red.
7. Removing the device from the Z-Wave network doesn’t cause factory reset.
Product Usage
Calibration
Calibration is a process during which a device learns the position of the
limit switches and a motor characteristic.
Calibration is mandatory in order for the device to correctly recognize a
roller blind position.
The procedure consists of an automatic, full movement between the limit
switches (up, down, and up again).
Automatic calibration using the menu:
1. Press and hold PROG button to enter the menu.
2. Release button when the device glows blue.
3. Quickly click the button to confirm.
4. The device will perform the calibration process, completing full cycle –
up, down and up again. During the calibration the LED blinks blue.
5. If the calibration is successful, the LED indicator will glow green, if
the calibration is failed, the LED indicator will glow red.
6. Test whether the positioning works correctly.
Automatic calibration using the parameter
1. Set parameter 150 to 3.
2. The device will perform the calibration process, completing full
cycle – up, down and up again. During the calibration the LED
blinks blue.
3. If the calibration is successful, the LED indicator will glow green,
if the calibration is failed, the LED indicator will glow red.
4. Test whether the positioning works correctly.
Manual positioning of slats in venetian blinds mode
1. Set parameter 151 to 1 (90″°) or 2 (180″°), depending on the rotation
capability of the slats.
2. By default, time of transition between extreme positions is set to 15 (1.5
seconds) in parameter 152.
3. Turn slats between extreme positions using up or down switch:
• If after full cycle a blind starts moving up or down – decrease value of
parameter 152,
• If after full cycle the slats does not reach end positions -” increase
value of parameter 152,
4. Repeat previous step until satisfactory positioning is achieved.
5. Test whether the positioning works correctly. Correctly configured slats
should not force the blinds to move up or down.
Operating
The device allows for connecting switch to the S1 and S2 terminals.
These may be monostable or bistable switches.
Switch buttons are responsible for managing the blind’s movement.
Description:
” UP – Switch connected to the S1 terminal
” DOWN – Switch connected to the S2 terminal
General tips:
• You can perform/stop movement or change direction using switch/es
• If you set flowerpot protection option the down movement action will
perform only to defined level
• If you control only a venetian blind position (not slats rotation) the
slats will back to their previous position (in aperture level 0-95%).
Favorite position
Your device has a built-in mechanism for setting favorite positions. You can
activate it by double-clicking on the monostable switch(es) connected to the
device or from the mobile interface (mobile app).
Favorite roller blind position
You can define the favorite position of the blinds. It can be set in parameter
159. The default value is set to 50%.
Favorite slats position
You can define the favorite position of the slats angle. It can be set in
parameter 160. The default value is set to 50%.
Pot protection
Your device has a built-in mechanism to protect, for example, flowers on the
windowsill. This is the so-called virtual limit switch.”
You can set its value in parameter 158. The default value is 0 – this means
that the roller blind will move between the maximum end positions.
LED indicators
The built-in LED shows the current status of the device. When the device is
powered: Green: Device added to Z-Wave network (non-secure, S0, S2 not
Authenticated)
Megenta: Device added to Z-Wave network (Security S2 Authenticated)
Red: Device not added to the Z-Wave network
Blinking Cyan: Update in progress
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 1 | Lifeline |
---|---|---|
2 | 5 | Window Covering |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 20: Switch type
This parameter determines with which switches types and in which mode the S1
and S2 inputs operate
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Monostable switches – click to move |
---|---|
1 | Monostable switches – hold to move |
2 | Single monostable switch |
3 | Bistable switches |
4 | Single bistable switch |
5 | Three-state switch |
Parameter 24: Buttons orientation
This parameter allows reversing the operation of the buttons.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | default |
---|---|
1 | revered |
Parameter 25: Outputs orientation
This parameter allows reversing the operation of O1 and O2 without changing
the wiring (e.g. in case of invalid motor connection).
Size: 1 Byte, Default Value: 0
SettingDescription
0 | default |
---|---|
1 | reversed |
Parameter 40: First button – scenes sent
This parameter determines which actions result in sending scene IDs assigned
to them. Values can be combined (e.g. 1+2=3 means that scenes for single and
double click are sent). Enabling scenes for triple click disables entering the
device in learn mode by triple clicking.
Size: 1 Byte, Default Value: 15
SettingDescription
0 | No scene active |
---|---|
1 | Key pressed 1 time |
2 | Key pressed 2 times |
4 | Key pressed 3 times |
8 | Key hold down and key released |
15 | All scenes active |
Parameter 41: Second button – scenes sent
This parameter determines which actions result in sending scene IDs assigned
to them. Values can be combined (e.g. 1+2=3 means that scenes for single and
double click are sent). Enabling scenes for triple click disables entering”
the device in learn mode by triple clicking.
Size: 1 Byte, Default Value: 15
SettingDescription
0 | No scene active |
---|---|
1 | Key pressed 1 time |
2 | Key pressed 2 times |
4 | Key pressed 3 times |
8 | Key hold down and key released |
15 | All scenes active |
Parameter 150: Calibration
To start automatic calibration, select the value 3. When the calibration
process is successful, the parameter takes the value 1. When automatic
calibration fails, the parameter takes the value 2. If the transitions times
for the device are changed manually in the parameter (156/157), the parameter
150 will takes the value 4.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Device is not calibrated |
---|---|
1 | Autocalibration successful |
2 | Autocalibration failed |
3 | Calibration process |
4 | Manual calibration |
Parameter 151: Operating mode
This parameter allows you to adjust the operation, depending on the
connected device. In the case of venetian blinds, the angle of rotation of the
slats must also be selected.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Roller blind, Awning, Pergola, Curtain |
---|---|
1 | Venetian blind 90″° |
2 | Venetian blind 180″° |
Parameter 152: Venetian blind – slats full turn time
For Venetian blinds the parameter determines time of full turn cycle of the
slats. The parameter is irrelevant for other modes.
Size: 2 Byte, Default Value: 15
SettingDescription
0 – 65535 | Time to turn (0,1s) |
---|
Parameter 156: Time of up movement
This parameter determines the time it takes to reach full opening.
The value is set automatically during the calibration process. It should be
manually set in case of problems with the autocalibration.
Size: 2 Byte, Default Value: 600
SettingDescription
0 – 65535 | Time to turn (0,1s) |
---|
Parameter 157: Time of down movement
This parameter determines the time it takes to reach full closure.
The value is set automatically during the calibration process. It should be
manually set in case of problems with the autocalibration.
Size: 2 Byte, Default Value: 600
SettingDescription
0 – 65535 | Time to turn (01s) |
---|
Parameter 158: Virtual limit switch. The pot protection
This parameter allows you to set a fixed minimum level of lowering the
shutter. For example, to protect a flowerpot located on a windowsill.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 99 | Position % |
---|
Parameter 159: Favorite position – opening level
This parameter allows you to define your favorite aperture level.
Size: 1 Byte, Default Value: 50
SettingDescription
0 – 99 | Position % |
---|---|
255 | Functionality disabled |
Parameter 160: Favorite position – slat angle
This parameter allows you to define your favorite position of the slat
angle. The parameter is used only for venetian blinds.
Size: 1 Byte, Default Value: 50
SettingDescription
0 – 99 | Position % |
---|---|
255 | Functionality disabled |
Technical Data
Dimensions | 46 x 36x 20 mm |
---|---|
Weight | 28 gr |
Hardware Platform | ZG23 |
EAN | 5902701703899 |
IP Class | IP 20 |
Voltage | 230V |
Device Type | Window Covering Endpoint Aware |
Generic Device Class | Multilevel Switch |
Specific Device Class | Motor Control Device (B) |
Firmware Version | 08.00 |
Z-Wave Version | 07.12 |
Certification ID | ZC14-23120375 |
Z-Wave Product Id | 0x010f.0x0304.0x1000 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Ss Basic
- Application Status
- Switch Multilevel
- Meter
- Transport Service
- Association Grp Info
- Device Reset Locally
- Central Scene
- Zwaveplus Info
- Supervision
- Configuration
- Alarm
- Manufacturer Specific
- Powerlevel
- Protection
- Firmware Update Md
- Association
- Version
- Indicator
- Multi Channel Association
- Security
- Security 2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>