MW NTU-1700 Series 1700W High Reliable True Sine Wave with UPS DC-AC Power Inverter Owner’s Manual
- June 8, 2024
- MW
Table of Contents
MW NTU-1700 Series 1700W High Reliable True Sine Wave with UPS DC-AC
Power Inverter
OVERVIEW
Features
- Built-in UPs function (AC by-pass)
- True sine wave output (THD<3%)
- High surge power up to 3400WN
- Temperature-controlled cooling fan
- AC output voltage and frequency selectable by DIP S.W
- -25C~+7o’C wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
- Protections
- Input Reverse polarity/ DC low alarm / DC low shutdown/Over voltage
- Output: Short circuit/Overload/Over temp.
- Battery over-discharge protection (low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Remote controller
- (IRC1, IRC2, and IRC3 accessories are sold separately, please refer to: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1)
- Support RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately)
- Carry handle accessory available(Order NO.: DS-Carry handle, sold separately)
- Conformal coating
- 3 years warranty
Applications
- Home and office appliance
- Power tools
- Portable equipment
- Vehicle
- Yacht
- Off-grid solar power system
- Wireless network
- Telecom or datacom system
Description
NTU-1700 is a 1700W highly reliable off-grid true sine wave DC-AC power inverter with built-in UPS function(AC by-pass). Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high quality fan with low acoustic noise, 3400W peak power, adjustable AC output voltage and frequency, -25+70C wide operating temperature range, complete protection features, and etc. Combined with batteries, the NTU-1700 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, induction stove, air conditioner, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment. and etc.
Model Encoding
SPECIFICATION
__
MODEL NO.
| NTU-1700-112| NTU-1700-124| NTU-1700-148| NTU-1700-212|
NTU-1700-224| NTU-1700-248
---|---|---|---|---|---|---
= US, GFCI, UN| = EU, CN, AU, UK, UN
__
__
__
__
__
AC OUTPUT
| RATED POWER(Continuous)| 1500W| 1700W
OVER RATED POWER(3 Min.)| 1750W| 2000W
PEAK POWER(10 Sec.)| 2250W| 2550W
SURGE POWER(30 Cycles)| 3000W| 3400W
AC VOLTAGE| Default setting set at 110VAC| Default setting set at 230VAC
100 / 110 / 115 / 120Vac selectable by DIP S.W| 200 / 220 / 230 / 240Vac
selectable by DIP S.W
FREQUENCY| Default setting set at 60±0.1Hz| Default setting set at
50±0.1Hz
50/60Hz selectable by DIP S.W| 50/60Hz selectable by DIP S.W
WAVEFORM **Note.1| True sine wave (THD<3%)
AC REGULATION| ±3.0% at rated input voltage
FRONT PANEL LED**| Please see page 5
__
__
__
DC INPUT
| DC VOLTAGE| 12Vdc| 24Vdc| 48Vdc| 12Vdc| 24Vdc| 48Vdc
VOLTAGE RANGE (Typ.)| 10 ~ 16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc| 10 ~
16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc
DC CURRENT (Typ.)| 150A| 75A| 37.5A| 170A| 85A| 42.5A
NO LOAD DISSPATION (SAVING MODE)(Typ.) Note.2| Default disable, auto
detect AC output load≦10W will be changed to saving mode
<8W
OFF MODE CURRENT DRAW| ≦1mA
EFFICIENCY (Typ.) Note.1| 89%| 90%| 91%| 89%| 92%| 93%
BATTERY TYPES| Lead Acid or li-ion
PROTECTION| DC INPUT| FUSE (INTERNAL)| 40A6| 40A3| 25A3|
40A6| 40A3| 25A3
__
LOW
| ALARM| 11±0.3Vdc| 22±0.5Vdc| 44±1Vdc| 11±0.3Vdc| 22±0.5Vdc| 44±1Vdc
SHUTDOWN| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc
RESTART| 12.5±0.3Vdc| 25±0.5Vdc| 50±1Vdc| 12.5±0.3Vdc| 25±0.5Vdc|
50±1Vdc
__
HIGH
| ALARM| 15.5±0.3Vdc| 31±0.5Vdc| 62±1Vdc| 15.5±0.3Vdc| 31±0.5Vdc|
62±1Vdc
SHUTDOWN| 16.5±0.3Vdc| 33±0.5Vdc| 66±1Vdc| 16.5±0.3Vdc| 33±0.5Vdc|
66±1Vdc
RESTART| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc
BAT. POLARITY| By internal fuse open
AC OUTPUT| OVER TEMPERATURE| Protection type : Shut down o/p
voltage, re-power on to recover
OUTPUT SHORT| Protection type : Shut down o/p voltage, re-power on to
recover
OVER LOAD (Typ.)| 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10
sec.
Protection type : Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER| 15A| 10A
GFCI PROCTECTION| UL458 (Only for “GFCI” AC socket, by request)| None
__
FUNCTION
| REMOTE CONTROL| CONNECTOR| Power ON-OFF remote control by
front panel dry contact connector(by RELAY), Open : Normal work ; Short :
Remote off
ACCESSORY| Remote controller sold separately, Order No.: IRC1,IRC2,IRC3
RS-232 COMMUNICATION| RS-232 ~ RJ11 Type connector (Please refer to page
4 for more details)
AC UPS MODE| AC INPUT RANGE| 100/110/115/120Vac±16%, recover±13%|
200/220/230/240Vac±16%, recover±13%
FREQUENCY RANGE| 45 ~ 65Hz
TRASFER TIME(Typ.)| 10ms inverter AC by pass
__
ENVIRONMENT
| WORKING TEMP.| -25 ~ +70℃(Refer to “Derating curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-
condensing
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
__
__
__
__
__
__
__
__
__
SAFETY
& EMC
(Note.5)
| SAFETY STANDARDS| CB IEC62368-1,Dekra BS EN/EN62368-1,UL458, E13,EAC TP TC 004,AS/NZS 62368.1 approved
(Please refer to next page“AC output socket” table for more details)
WITHSTAND VOLTAGE| DC I/P – AC I/P:3.0KVac DC I/P – AC O/P:3.0KVac AC
O/P – FG:1.5KVac
__
__
EMC EMISSION
| Parameter| Standard| Test Level / Note
Radiated| FCC for 112,124,148 only(expect for Type-UN)| Class A
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)| Class A
Conducted| FCC for 112,124,148 only(expect for Type-UN)| Class A
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)| Class A
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
__
__
__
__
EMC IMMUNITY
| BS EN/EN55024, BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2
EFT / Burst| BS EN/EN61000-4-4| Level 2, 1KV
Surge| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line 2KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 2
Magnetic Field| BS EN/EN61000-4-8| Level 1
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
95% interruptions 250 periods
OTHERS| MTBF| 421.9K hrs min. Telcordia TR/SR-332
(Bellcore) ; 45.3K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 40018470mm (LWH)
PACKING| 4.63Kg; 2pcs/ 12Kg/ 1.76CUFT
NOTE|
- Efficiency, AC regulation and THD are tested by 1350W load, linear load at 12.5Vdc/25Vdc/50Vdc input voltage
- No load disspation at non-saving mode(Typ.): 112/124/148 for 16W, 212/224/248 for 29W.
- All parameters not specified above are measured at rated load, 25C of ambient temperature and set to factory setting.
- Internal pre-start circuit, the setup time is 8s.
- The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimeraspx
AC Output Socket
DERATING CURVE
IRC1/2/3 Remote Controller (Accessory sold separately)
- IRC1/IRC2/IRC3 is the monitoring and control unit.
- IRC1/IRC2/IRC3 can decode the RS-232 signals sent by the inverter series and display through digital meters.
- Note: Part of the control signals will not function properly due to different compliance of each model.
- Please refer to for more detail: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1
Support RS-232 Communication
- The internal data of single NTU-1700 can read through RS-232.
- Please refer to for more detail: http://www.meanwell.com/manual.html
- RJ11-RS232 Communication cable should be ordered separately, Order No.: DS-RJ11-R$232
Remote ON-OFF Control (Built-in)
Remote ON-OFF | AC Output Status |
---|---|
Open | power inverter ON |
Short | power inverter OFFC |
AC Output Voltage. Frequency, Power saving mode selectable by DIP SW
- Output voltage and frequency setting factory settings are either 110Vac/60Hz or 230Vac/50 Hz, users are able to adjust the voltage and frequency, through the DIP switch of position 1,2,3,4 on the panel.
AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW
SW1| SW2| SW3| SW4
OFF| OFF :| 100Vac or 200Vac|
ON: 50Hz
|
ON: Saving mode
OFF| ON :| 110Vac or 220Vac
ON| OFF :| 115Vac or 230Vac|
OFF: 60Hz
| OFF: Non-Saving mode
ON| ON :| 120Vac or 240Vac
LED STATUS
Normal work
Abnormal status
MECHANICAL SPECIFICATION
R.C Connector: JST B-XH or equivalent
Remote Control | Mating Housing | Terminal |
---|---|---|
Pin 1,2 Open: Normal work | JST XHP |
or equivalent
| JST SXH-001T
or equivalent
Pin 1,2 Short: Remote off
Remote port connector (RJ11)
Assignment | Rx | GND | Tx |
---|---|---|---|
Remote port | 2 | 3 | 4 |
DB9 | 3 | 5 | 2 |
Accessory List
Communication cable (Optional accessory, Power inverter, and Communication cable should be ordered separately)
MW’s Order No. | Item | Quantity |
---|
DS-RJ11-RS232
| |
1
Carry handle (Optional accessory, Power inverter and Pull handle should order separately)
MW’s Order No. | Item | Quantity |
---|---|---|
DS-Carry Handle |
1
|
Handle
|
1
2
|
Footpad
|
4
3
|
Screw
|
2
- Handle
- Footpad
TYPICAL APPLICATION
-
Battery Bank
-
Off-Grid DC/AC Solar Inverter (NTU series)
-
AC Outlet
-
utility Input (Shore)
-
AC/DC Battery Chargers (PB/NPBINPP series)
-
Battery Bank
-
Off-Grid AC/DC
-
Power Inverter (NTU series)
-
AC Outlet
-
AC/DC Battery Charger (PB/NPB/NPP series)
-
Battery Bank
-
Off-Grid DC/AC Inverter (NTU series)
-
AC Outlet
INSTALLATION MANUAL
- Please refer to:http://www.meanwell.com/manual.html
- File Name: NTU-1700-SPEC 2022-01-18
- 1700W High Reliable True Sine Wave with UPS DC-AC Power Inverter
Documents / Resources
| MW
NTU-1700 Series 1700W High Reliable True Sine Wave with UPS DC-AC Power
Inverter
[pdf] Owner's Manual
NTU-1700 Series 1700W High Reliable True Sine Wave with UPS DC-AC Power
Inverter, NTU-1700 Series, 1700W High Reliable True Sine Wave with UPS DC-AC
Power Inverter, 1700W High Reliable True Sine Wave, UPS DC-AC Power Inverter,
DC-AC Power Inverter, DC Power Inverter, AC Power Inverter, Power Inverter,
Inverter
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>