INOX PD97ES Electrified Mortise Lockset for Sliding Door Instruction Manual
- June 4, 2024
- INOX
Table of Contents
INOX PD97ES Electrified Mortise Lockset for Sliding Door
PD97ES Components List
| Part Lists| Passage| Entry| Patio/Exit|
Storeroom
---|---|---|---|---|---
A| X Series Trim / Surface Pull| 1 EA| 1 EA| 1 EA| 1 EA
B| Cylinder & Keys| –| 1 EA| –| 1 EA
C| Thumbturn| –| 1 EA| 1 EA| –
D| Mortise Lock & Faceplate| 1 EA| 1 EA| 1 EA| 1 EA
E| Strike Plate with Dust Box| 1 EA| 1 EA| 1 EA| 1 EA
- 5 – Compression Inserts
- 2 – M4x1-3/8” (35mm) Machine Screw
- 2 – Safety Lock Washer
- 2 – M4.2x19mm Self Tapping Screw for Metal Door
- 2 – M4x19mm Wood Screw for Wood Door
- 1 – 3mm Allen Key
- 1 – Wave Washer
- 4 – M4x19mm Self Tapping Screw
- 4 – M4x19mm Wood Screw
- 1 – 3mm Allen Key
- 2 – M4x30mm Combo Screw
- 3 – M4x6mm Machine Screw
- 4 – M4x14 Machine Screw
- 1 – pc of 2P Extension Wire
- 1- pc of 3P Extension Wire
- 1 – pc of 4P Extension Wire
Installation Instructions
PD97ES Electrified Mortise Lockset for Sliding Door with Autolocking and Monitoring Switches with X Series Trim / Surface Pulls
PD97ES = PD97PT-ATL+ REX + DBM + DPS
- PD97PT-ATL = PD97 with Built-in Power Contacts and Auto-locking
- REX = Request-to-Exit Monitoring Switch
- DBM = Deadbolt Monitoring Switch
- DPS = Door Position Switch
This product has been tested and certified for UL1034 and UL294.
It is intended to be installed in accordance with the installation wiring
diagram, mechani- cal assembly drawings provided with each product, the local
authority having jurisdiction (AHJ) and the National Electric Code, NFPA 70.
When installed in fail secure mode, the local authority shall be consulted
with regard to the use of possible panic hardware to allow emergency exit from
the secure area.
PD97ES Electrified Mortise Lockset with Sensors
WARNING:
Make sure the connected relay has a timed function to control the power
supply. PD97ES lock only requires 3~6 seconds of continuous power to engage or
retract the deadbolt. Continuous power longer than needed will damage the
motor. The range of the power supplying duration is subject to the soft close
or weatherstripping conditions on the sliding door.
Autolocking
- When the sliding door closes, a Built-in Door Position Switch (DPS) provides a signal to the Strike PCB, which triggers a wire connected to the Relay REX input port to send power to the strike.
- The strike will transfer power to the lock via the Power Contacts, which then activates the built-in motor to engage the deadbolt into the strike, enabling the door opening to be locked automatically.
- A built-in deadbolt monitoring switch (DBM) will confirm once the deadbolt is fully engaged into the strike.
Abnormality Checking and Relocking
In an autolocking cycle, if Deadbolt Monitoring Switch (DBM) does not sense the deadbolt is set in the proper position, a new signal will be sent to relay for the power contact to actives the motor to dis-engage then re-engage the deadbolt. This checking and relocking operation will be repeated automatically up to three (3) times, or until deadbolt is detected in correct position.
Alarm
- After 3 relocking operations, if DBM switch still cannot detect the deadbolt is situated in the right position, an integrated speaker will chime 60 seconds to notify the user that the opening has failed to lock.
- Once the door is reopened, the auto-locking and alarm functions will reset.
To ensure this function is activated properly, please ensure the Purple and
Orange wires are properly connected to the Relay REX Input port. Please refer
to wiring diagram.
DPS and DBM sensors have been programmed internally to support this function.
There is no need to connect the DPS/DBM to any monitoring device to support
this function.
Optional Accessories
Accessories are shown for reference only and not evaluated for UL294 or UL1034. Make sure the connected relay has a timed function to control the power supply.
Installation Instructions for Passage Function:
- Install mortise lockcase in door prep.
- Install the compression inserts on both sides.
- Install the outside X series trim with spindle, do not tighten the set screws. 3A. Alternative Option: Install outside surface pull without spindle and do not tighten the set screws.
- Install outside X series trim, do not tighten the set screws.
- Install the inside rose cover. XGT is threaded, XGS requires a set screw. NOTE: After the lever is installed, fully tighten the set screws on both the inside and outside trims. See Section C-C. NOTE: XGS square roses needs to be aligned prior to tightening the set screw on bottom of rose cover. See Section D-D.
- Install armored faceplate with M4x6mm screws.
Installation Instructions for Entry Function:
- Install mortise lockcase in door prep. NOTE: DO NOT tighten faceplate screws until the cylinder has been installed.
- Screw on outside cylinder escutcheon ring with spacer.
- Install mortise cylinder. NOTE: Key slot on cylinder should be on lower center position. See section A-A. Using a screwdriver, tighten the screws on the lockcase to position the cylinder into place. See Section B-B.
- Mount inside privacy thumbturn rose with M4x19mm screws. Mount rose cover and clear washer before mounting thumbturn piece. Use Allen Key to tighten set screws.
- Install the compression inserts on both sides.
- Install outside X series trim, do not tighten the set screws
- Alternative Option: Install outside surface pull without spindle and do not tighten the set screws.
- Install inside X series trim and tighten the M4x1-3/8” screws.
- Install the inside rose cover. XGT is threaded, XGS requires a set screw. NOTE: After the lever is installed, fully tighten the set screws on both the inside and outside trims. See Section C-C. NOTE: XGS square roses needs to be aligned prior to tightening the set screw on bottom of rose cover. See Section D-D.
- Install armored faceplate with M4x6mm screws.
Installation Instructions for Storeroom Function:
- Install mortise lockcase in door prep. NOTE: DO NOT tighten faceplate screws until the cylinder has been installed.
- Screw on outside cylinder escutcheon ring with spacer.
- Install mortise cylinder. NOTE: Key slot on cylinder should be on lower center position. See section A-A. Using a screwdriver, tighten the screws on the lockcase to position the cylinder into place. See Section B-B.
- Install the compression inserts on both sides.
- Install outside X series trim, do not tighten the set screws.
- Alternative Option: Install outside surface pull without spindle and do not tighten the set screws.
- Install outside X series trim, do not tighten the set screws.
- Install the inside rose cover. XGT is threaded, XGS requires a set screw. NOTE: After the lever is installed, fully tighten the set screws on both the inside and outside trims. See Section C-C. NOTE: XGS square roses needs to be aligned prior to tightening the set screw on bottom of rose cover. See Section D-D.
- Install armored faceplate with M4x6mm screws.
Installation Instructions for PD97ES Strike:
WARNING:
Make sure the connected relay has a timed function to control the power
supply. PD97ES lock only requires 3~6 seconds of continuous power to engage or
retract the deadbolt. Continuous power longer than needed will damage the
motor. The range of the power supplying duration is subject to the soft close
or weatherstripping conditions on the sliding door.
- Install reinforcement plate behind the door frame cut out, secure the plate with machine screws and tighten.
- Connect the red/black/white Molex receptor to the power and output relays.*
- Connect the orange/blue Molex receptor to the Input REX port of the relay.
- Connect purple/yellow/green/grey Molex receptor to a monitoring device.
- Connect the black/black Molex receptor between deadbolt and main PCB unit on the strike to enable the deadbolt sensor to active autolocking. See Section E-E.
- Install the dust box.
- Install the buckle plate and tighten the screws.
Electrical rating for this product = Lock / Strike Rated 10-26VDC 1.5 Amps.
Installation Instructions for Patio Function:
-
Install mortise lockcase in door prep. NOTE: DO NOT tighten faceplate screws until the cylinder has been installed.
-
Mount inside privacy thumbturn rose with M4x19mm screws. Mount rose cover and clear washer before mounting thumbturn piece. Use Allen Key to tighten set screws.
-
Install the compression inserts on both sides.
-
Install outside X series trim, do not tigthen the set screws.
-
Alternative Option: Install outside surface pull without spindle and do not tighten the set screws.
-
Install outside X series trim, do not tighten the set screws.
-
Install the inside rose cover. XGT is threaded, XGS requires a set screw. NOTE: After the lever is installed, fully tighten the set screws on both the inside and outside trims.
See Section C-C. NOTE: XGS square roses needs to be aligned prior to tightening the set screw on bottom of rose cover. See Section D-D. -
Install armored faceplate with M4x6mm screws.
PD97ES Wiring Diagram
This product for UL compliance shall be used with UL Listed access control and burglar alarm control panels / peripheral devices. Accessories are shown for reference only and not evaluated for UL294 or UL1034.