BANNER CL50 Pro Column Light User Guide

June 4, 2024
BANNER

BANNER CL50 Pro Column Light

IO-Link Data Map

This document refers to the following IODD file: Banner_Engineering- CL50RGBIOL-20210903-IODD1.1.xml. The IODD file and support files can be found on www.bannerengineering.com under the download section of the product family page.

Communication Parameters

The following communication parameters are used.

Parameter Value
IO-Link revision V1.1
Process Data In length N/A
Process Data Out length 3-bytes
Bit Rate 38400 bps
Minimum cycle time 20 ms
Port class A
SIO mode No
Smart sensor profile N/A
Block parameterization Yes
Data Storage Yes

IO-Link Process Data In (Device to Master)

Not applicable.

IO-Link Process Data Out (Master to Device)

Run Mode


Subindex| Name| Number of Bits| Data Values
1| Color 1| 4| 0 = Green, 1 = Red, 2 = Orange, 3 = Amber, 4 = Yellow, 5 = Lime Green, 6 = Spring Green, 7 = Cyan, 8 = Sky Blue, 9 = Blue, 10 = Violet, 11 = Magenta, 12 = Rose, 13 = White, 14 = Custom 1, 15 = Custom 2
2| Color 2| 4| 0 = Green, 1 = Red, 2 = Orange, 3 = Amber, 4 = Yellow, 5 = Lime Green, 6 = Spring Green, 7 = Cyan, 8 = Sky Blue, 9 = Blue, 10 = Violet, 11 = Magenta, 12 = Rose, 13 = White, 14 = Custom 1, 15 = Custom 2
3| Animation| 3| 0 = Off, 1 = Steady, 2 = Flash, 3 = Two Color Flash, 4 = Intensity Sweep
4| Pulse Pattern| 3| 0 = Normal, 1 = Strobe, 2 = Three Pulse, 3 = SOS, 4 = Random
5| Speed| 2| 0 = Medium, 1 = Fast, 2 = Slow
6| Color 1 Intensity| 3| 0 = High, 1 = Low, 2 = Medium, 3 = Off, 4 = Custom
7| Color 2 Intensity| 3| 0 = High, 1 = Low, 2 = Medium, 3 = Off, 4 = Custom
8| Audible State| 2| 0 = Off, 1 = On, 2 = Pulsed, 3 = SOS Pulse
Octet 0|  |  |  |  |  |  |  |
---|---|---|---|---|---|---|---|---
Bit Offset| 23| 22| 21| 20| 19| 18| 17| 16
Subindex| 8| 7| 6
Value| 1| 0| 0| 0| 0| 0| 0| 0
Example| Audible State: On| Color 2 Intensity: High| Color 1 Intensity: High
Octet 1|  |  |  |  |  |  |  |
---|---|---|---|---|---|---|---|---
Bit offset| 15| 14| 13| 12| 11| 10| 9| 8
Subindex| 5| 4| 3
Value| 1| 0| 0| 0| 0| 0| 1| 1
Example| Speed: Fast| Pulse Pattern: Normal| Animation: Two Color Flash
Octet 2|  |  |  |  |  |  |  |
---|---|---|---|---|---|---|---|---
Bit offset| 7| 6| 5| 4| 3| 2| 1| 0
Subindex| 2| 1
Value| 0| 0| 0| 1| 0| 0| 0| 0
Example| Color 2: Red| Color 1: Green

These parameters can be read from and/or written to an IO-Link model of the CL50 Pro.

Index| Sub index| Name| Length| Value Range| Default| Access Rights| Data Storage?| AOI
---|---|---|---|---|---|---|---|---
0| 1-16| Direct Parameter Page 1 (incl. Vendor ID & Device ID)| | | | rw| |
1| 1-16| Direct Parameters Page 2|  |  |  | rw|  |
2|  | Standard Command|  | 130 = Restore Factory Settings|  | wo|  |
3-11|  |  |  |  |  |  |  |
12|  | Device Access Locks
0| Parameter (write) Access Lock| Boolean| 0 = off, 1 = on| 0| rw| y|
1| Data Storage Lock| Boolean| 0 = off, 1 = on| 0| rw| y|
2| Local Parameterization Lock| Boolean| 0 = off, 1 = on|  | rw| y|
3| Local User Interface Lock| Boolean| 0 = off, 1 = on|  | rw| y|
13-15|  |  |  |  |  |  |  |
16|  | Vendor Name string|  | Banner Engineering Corporation|  | ro|  |
17|  | Vendor Text string|  | More Sensors. More Solutions.|  | ro|  |
18|  | Product Name string|  | CL50|  | ro|  |
19|  | Product ID string|  | CL50PKQ|  | ro|  |
20|  | Product Text string|  | CL50 Pro|  | ro|  |
21|  | Serial Number|  |  |  | ro|  |
22|  | Hardware Revision|  |  |  | ro|  |
23|  | Firmware Version|  |  |  | ro|  |
24|  | App Specific Tag (user defined)|  |  |  | rw| y|
25-35|  |  |  |  |  |  |  |
36|  | Device Status| 8-bit uinteger| 0 = Device is OK, 1 = Maintenance required, 2 = Out of specification, 3 = Functional check, 4 = Failure, 5..255 = Reserved|  | ro|  |
37| 1-6| Detailed Device Status| Array[6] of 3- octet|  |  | ro|  |
38-63|  |  |  |  |  |  |  |
75|  | Additional Settings (subindex access supported)
1| Custom Intensity (0 – 100%)| 8-bit uinteger| 0-100| 100| rw| y|
2| Custom Flash Rate (0.5 – 20)| 8-bit uinteger| 0.5-20| 15| rw| y|
4| Restrict To Gamut| Boolean| 0=Off, 1=On| 0| rw| y|
5| Reserved| 7-bit uinteger|  | 0|  |  |
76|  | Custom 1 (subindex access supported)
1| Red| 8-bit uinteger| 0-255| 255| rw| y|
2| Green| 8-bit uinteger| 0-255| 255| rw| y|
3| Blue| 8-bit uinteger| 0-255| 255| rw| y|
77|  | Custom 2 (subindex access supported)
1| Red| 8-bit uinteger| 0-255| 255| rw| y|
2| Green| 8-bit uinteger| 0-255| 255| rw| y|
3| Blue| 8-bit uinteger| 0-255| 255| rw| y|

IO-Link Events

Events and Error Types are acyclic transmissions from the IO-Link device to the IO-Link master. Events can be error messages and/or warning or maintenance data.

Event Types

Code| Type| Description
0 (0x0000)| Notification| No malfunction
20480 (0x5000)| Error| Device hardware fault/Device exchange
20753 (0x5111)| Error| Primary supply voltage under-run/Check tolerance of power supply
Error Types

Code| Additional Code| Name| Description
128 (0x80)| 0 (0x00)| Device application error – no details| Service has been refused by the device application and no detailed information of the incident is available
17 (0x11)| Index not available| Access occurs to a not existing device
18 (0x12)| Subindex not available| Access occurs to a not existing subindex
32 (0x20)| Service temporarily not available| Parameter is not accessible because of the current state of the device application
35 (0x23)| Access denied| Write access on a read-only parameter
48 (0x30)| Parameter value out of range| Written parameter value is outside its permitted value range
49 (0x31)| Parameter value above limit| Written parameter value is above its specific value limit
51 (0x33)| Parameter length overrun| Written parameter length is above its predefined length
52 (0x34)| Parameter length underrun| Written parameter length is below its predefined length
53 (0x35)| Function not available| Written command is not supported by the device application
54 (0x36)| Function temporarily unavailable| Written command is not available because of the current state of the device application
65 (0x41)| Inconsistent parameter set| Parameter inconsistencies were found at the end of the block parameter transfer, device plausibility check failed

© Banner Engineering Corp. All rights reserved

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals