SLOAN EBF-415 Washbasin Mixer Tap Instructions

June 9, 2024
SLOAN

SLOAN-OAN-EBF-415-Washbasin-Mixer-Tap-LOGO

SLOAN EBF-415 Washbasin Mixer Tap

SLOAN-OAN-EBF-415-Washbasin-Mixer-Tap-PRODUCT-IMAGE

Parts & Accessories

EBF-415 Deck Mount, battery
ETF-410 Deck Mount, hardwired

SPOUT ASSEMBLY| SLOAN-OAN-EBF-415-Washbasin-Mixer-
Tap-01|
---|---|---
Description| | Code No.      Part No.| |
Spout Assembly EBF-415/ETF-410| 0315250| EFP1019A|
Sensor & Cable Assembly| 3315431| EFP114A|
Spout Mounting Kit| 0315311| EFP117A|
TRIMPLATE OPTIONS| BELOW DECK ASSEMBLIES|
Description| | Code No.          Part No.| Description| Code No.| Part No.|
4”| 3365468| ETF312A|
Control Box No Turbine| 0367039| EFP39A|
8”| 3365024| ETF510A|
Control Box Turbine 0.5 gpm| 0367040| EFP40A|
SPRAYHEAD OPTIONS|
Control Box Turbine 1.5 gpm| 0367011| EFP11A|
Description| Type| Code No.       Part No.|
Quick Connect Spout Hose 24”| 0367025| EFP25|
0.35 GPM/1.3 Lpm| MLM| 33620002| EFP119|
Control Box Cover w/Screw| 0367010| EFP10A|
0.5 GPM/1.9 Lpm| MLM| 33620001| EFP120|
Solenoid Assembly| 0367103| EFP103A|
SLOAN-OAN-EBF-415-Washbasin-Mixer-Tap-02 SLOAN-OAN-
EBF-415-Washbasin-Mixer-Tap-03 SLOAN-OAN-
EBF-415-Washbasin-Mixer-Tap-04|
Battery Pack| 3324113| EFX8A|
Double Inlet Tee Filter Assembly| 0367028| EFP28A|
BDM & Single Inlet Tee Filter Assembly Kit| 0367099| EFP99A|
BDT & Single Inlet Tee Filter Assembly Kit| 0367100| EFP100A|
Replacement Filter Pack-(5) Filter(5) Large O-rings (5) Small O
-rings| 0367101| EFP101A|
24 VAC Power Harness Assembly| 0367098| EFP98A|
110V/6 VDC Power Supply| 0362006| SFP6|
100-240 VAC/6 VDC Power Supply| 0362016| SFP36|
120/24 VAC Power Supply| 0365534PK| ETF-233|
120/24 VAC Power Supply (Canada) Plug-in| 0365879| ETF-416|
120/24 VAC Power Supply (Box Mount)| 0345370PK| EL-248-40|
Extension Cable| 0362017| SFP37|
Splitter Cable| 0362018| SFP38|
Gang Adapter Kit| 0362035| SFP35A|
Faucet to Module Ext. Cable*| 0367113| EFP113-A|

TROUBLESHOOTING INSTRUCTIONS FOR OPTIMA SENSOR ACTIVATED LAVATORY FAUCETS WITH THE NEW OPTIMA CONTROL BOXES AND THE SLOAN CONNECT SMARTPHONE APP.
NOTE: To automatically check battery strength, troubleshoot, diagnose and report faucet issues with a
wireless device, use the Sloan Smart Phone APP. The APP is available free-of- charge at the Apple iPhone APP store for iOS devices or the Google Play APP store for Android devices. For more information about the APP and its capabilities please visit www.Sloan.com.

FAUCET TROUBLESHOOTING GUIDE

LED indicator light in the IR (infrared) sensor is red
  1. Battery power is low.
    Install four (4) new AA sized alkaline batteries. Check that the orientation of each battery matches the positive (+) and negative (–) symbols shown in the bottom of the battery compartment. Re-attach battery compartment to control module. Green LED will illuminate. If the Green LED does not illuminate, remove battery compartment for 10 seconds and return into place.

Faucet DOES NOT function.

  1. Batteries not installed or are exhausted.
    Install four (4) AA sized alkaline batteries. Check that the orientation of each battery matches the positive (+) and negative (–) symbols shown in the bottom of the battery compartment. Reattach battery compartment to control module. Green LED will illuminate. If the Green LED does not illuminate, remove battery compartment for 10 seconds and return into place.

  2. Power Cable not installed (Hardwire models).
    Install power cable and check connection.

  3. Sensor Cable not installed.
    Install sensor cable and check connection. Confirm connection guide markings are aligned.

  4. Sensor range is set too short and is not detecting the target.
    Increase sensor detection range.

Sensor is activated but faucet DOES NOT deliver water.

  1. Faucet has initiated its adaptive sensing calibration program.
    Wait 60 seconds before activating faucet.

  2. Solenoid Cable not connected.
    Check solenoid cable connection. Confirm connection guide markings are aligned.

Sensor Range Requires Manual Adjustment.
Sensor Range is measured in units from 1 to 5, with 1 being closest to the faucet and 5 being farthest from the faucet. The factory default Sensor Range is 3.

  1. To determine what the current Sensor Range setting is, press the red “Sensor” button on the upper right hand corner of the Optima Control Box for 1 second. Five seconds after pressing the button, the green LED beside it will blink to indicate the Sensor Range setting. For example, if it is set at 2, the green LED will blink 2 times.

  2. To adjust the Sensor Range, press and hold the red “Sensor” button for three seconds and release once the green LED comes on to indicate that you are in Sensor Range adjustment mode. Then press the “Sensor” button one second at a time for however many times you wish to increase the range. For example, if the Sensor Range is set at 2 and you wish to increase it to 4, press the “Sensor” button two times for one second each time. If you wish to decrease the Sensor Range, follow the same procedure to enter into Sensor Range adjustment mode, and then press
    the “Sensor” button one second at a time. The button is designed to go up to 5 units and then back down to 1 unit. For example, if the Sensor Range is set at 4 and you wish to decrease it to 2, press the “Sensor” button three times for one second each time.

  3. To conform your changes, wait 5 seconds and then press the red “Sensor” button on the upper right hand corner of the Optima Control Box for 1 second. Five seconds after pressing the button, the green LED beside it will blink to indicate the Sensor Range setting. For example, if it is now set at 2, the green LED will blink 2 times.

Solenoid produces an audible “CLICK” when an object is placed in the detection zone of the sensor but NO water flows.

  1. Water supply to faucet is not open.
    Open supply stop(s).

  2. Inlet fitting filter is clogged.
    Remove, clean, and reinsert. Replace with EBF1004 solenoid filter kit if necessary.

  3. Aerator or spray head is clogged.
    Remove, clean, and reinsert.