TESLA TSL-HC-UFR102 Smart Thermometer User Manual
- June 9, 2024
- Tesla
Table of Contents
- TESLA TSL-HC-UFR102 Smart Thermometer
- Introduction
- Safety information
- Product Structure
- Battery Installation
- SETTING MODE
- Temperature unit setting
- PROPER USE OF THE UNIT
- APP Operation
- EXCEPTIONAL SITUATION
- CARE AND MAINTENANCE
- Maintenance
- SPECIFICATION
- EMC
- Technical description
- INFORMATION ABOUT DISPOSAL AND RECYCLING
- EU DECLARATION OF CONFORMITY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TESLA TSL-HC-UFR102 Smart Thermometer
Introduction
-
Your new Infrared thermometer uses advanced infrared (IR) tech-nology to measure temperature instantly and accurately on the body or object.
-
Easy to use and less measure-ment time
Tesla Smart Thermometer does not need to contact body or object to ensure the safety and hygiene. Its ergonomic design makes this thermometer be simple and very easy to check the tem-perature. It only takes 1 second to take measurement and reading. -
Body, ear and object tempera-ture modes
Tesla Smart Thermometer supports to measure tempera-ture of body surface, ear canal and object. Measuring range of object-temperature mode is 32.0°F-199.9°F (0.0°C -100.0°C). This means except body surface, ear canal temperature, it also supports to take the surface tem-perature of object temperature as below, -
Surface temperature of milk in the bottle
-
Surface temperature of baby bath
-
Environment temperature
-
Object mode is for reference only
-
Alarm sounds
When body temperature is over 99.5°F(37.5°C), an alarm sounds for 10 times -
Memory function
It stores up to 20 sets recent measurement data. -
Auto power off Automatically power off if left idle for 60±5seconds.
-
Measurement
Measurement time 1 second and the measurement distance is within 1 cm.
Please read the manual carefully before you use the unit and keep for future reference. -
Intended use
The Infrared Thermometer is continuous for the continuous measurement and monitoring of human body temperature from body surface, ear canal or ambient. The device is indicated for use by people of all ages at homecare and in hospital. -
Contraindication(s): None.
-
The patient is an intended operator.
Safety information
To assure the correct use of the product, basic safety measures should always
be followed inclu-ding the wcarning and the caution listed in the instruction
manual:
WARNING: This alert identities hazards that may cause serious personal
injury or death. CAUTION: This alert identities hazards that may cause minor
personal injury. product damage, or property damage.
- Tesla Smart Thermometer is not intended to substitute for a consultation with your physician. The forehead scan temperature serves as a reference only. It cannot be a judgment on fever.
- Basic safety precautions should always be observed, especially when the thermometer is used on or near children and disabled persons.
- Please place the device unrea-chable by young.
- Avoid direct sunlight.
- Do not touch the lens.
- No modification of this device is allowed.
- The swallowing of small parts like packing bag, battery, battery cover and so on may cause the suffocation.
- Please do not use a dilution agent, alcohol, or petrol to clean the unit.
- Please treat is gently and pre-vent the falling from a high place.
- Please do not immersed it in liquid.
- Never leave battery in the battery compartment for a long time without use, as they may leak and cause damage to the unit.
- Please take off the battery if you do not intend to use within 3 months. Replace with new batteries if the unit display a low battery symbol.
- Do not mix the old and new batteries together.
- Do not use during the trans-portation.
WARNING:
- Do not dispose of electrical appliances as unsorted municipal waste, use separate collection fa-cilities. Contact your local gover-nment for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
Classification
- Internally powered equipment;
- Type BF applied part;
- Protection against ingress of water or Particulate matter IP21;
- Not category AP/APG equipment;
- Mode of operation Continuo-us operation.
- The user must check that the equipment functions safely and see that it is in proper working condition before being used.
Product Structure
Display
- Object temperature mode
- Forehead temperature mode
- Ear temperature mode
- Temperature reading
- Memory Symbol
- battery Symbol
- Temperature unit(°C/°F)
Body
- Display Screen
- ON/OFF and measurement button
- Sensor head
- Protective cover
- Mode button
- °C/°F button
- Battery cover
Pull off the head cover
If you want to use the ear tempe-rature mode for measurement, please press
both sides of the head cover and pull the opening cap up.
Battery Installation
Remove the battery cover from the battery compartment insert the battery.
- Remove the battery cover from the battery compartment as the arrow direction accordingly.
- Insert 2 AAA powerful batteries into the compartment and ensure each battery is in the proper direction, Positive (+) and Negative (-) are displayed on the back of battery cover.
- Close the battery cover.
Low battery and replacement
When power on, the low battery symbol will display once the unit start to
work, and you must replace with new batteries, otherwise the unit can‘t work.
Battery type and replacement
Please use 2pcs AAA identical 1.5V alkaline batteries.
Do not use the batteries beyond their expiry date.
Please remove the batteries if you do not need to use for long time.
WARNING
Dispose of the battery in accordance with all federal, state and local laws.
To avoid fire and explosion hazard, do not burn or incinerate the battery.
SETTING MODE
Mode setting
- Forehead temperature mode After the power is turned off, the default mode is „forehead temperature mode“ or „ear tem-perature mode“. The switching mode is whether the head cover is on or not.
- Ear temperature mode Take off the head cover and automatically switch to ear temperature mode.
- Object mode
Under the power on state, press the Mode button briefly to switch to the object mode, and the screen object temperature icon lights up.
Note: The Body Mode is mainly used to measure the forehead temperature, and the Ear Mode is used to measure the ear tem-perature, then the Object Mode is used to measure the object temperature.
Temperature unit setting
Press °C/°F button when power on after you hear 1 beep, the screen will display °C or °F, Mode will change between °C and °F. When the °C/°F button is pressed. It will confirm the Celsius Unit automatically when you switch to °C, and confirm the Fahrenheit Unit automatically when you switch to °F. Then press „ON/OFF“ button make the confirmation selection.
Sound switch setting
Press and hold the Mode button for 3 seconds to enter the sound switch setting. Press the „ON/OFF“ button to confirm the selection, and after the setting, it will automatically return to the mode to be tested and wait for the measurement.
PROPER USE OF THE UNIT
Pre-measurement
About Normal Body Temperatu-re&Fever
The temperature in the forehead and temple area differs from the internal
temperature which is taken orally or rectally. Vasoconstriction, an effect
which constricts the blood vessels and cools the skin, can occur during the
early stages of a fever. In this case, the temperature measured by the
Infrared thermometer may be unusually low. If the measure-ment therefore does
not match the patient‘s own perception or is unusually low, peat the mea-
surement every 15 minutes. As a reference, you can also measure the internal
body temperature using a conventional oral or rectal thermometer.
Body temperature can vary from one individual person to next.
It also varies by location on the body and time of day. Below shows the
statistical normal ranges from different sites. Please keep in mind that
tempe-ratures measured from different sites, even at the same time, should not
be directly compared. Fever indicates that the body temperature is higher than
normal. This symptom may be caused by infection, overdressing or immunization.
Some people may not experience fever even when they are ill.
These include, but are not limited to, infants younger than 3 months old,
persons with compromi-sed immune systems, persons taking antibiotics,
steroids, or antipyretics (aspirin, ibuprofen, acetaminophen), or persons with
certain chronic illnesses. Please consult your physician when you feel ill
even if you do not have fever.
As a Body Thermometer
Press the ON/OFF to start the machine. The measurement pre-paration screen
will be displayed after one second. The °F icon will be on. Align the machine
with the forehead center and let the distance between the infrared thermometer
protective cover and the forehead be 1cm. Press the ON/OFF key to measure, and
the measurement result will be prompted.
Note:
- if the reading I < 99.5°F(37.5°C), the display will show the measurement together with 1 short beep.
- If the reading is 99.5°F(37.5°C) and<109.4°F(43°C), the buzzer 10 short beeps.
- As the forehead measurement temperature is likely to be affected by sweat, oil and the surroundings, the reading shall be taken as a reference only.
- If the probe is placed at an angle close to the forehead measurement, the reading will be affected by surrounding temperature.
- Babies‘ skin reacts very quickly in the ambient temperature. Therefore, do not take their temperature with the non-con-tact thermometer during/after breastfeeding, because the skin temperature maybe lower than the internal body temperature.
- The user and the infrared thermometer should be quiescence for at least 30 minutes under similar indoor conditions.
As an Ear Thermometer
Press the ON/OFF to start the machine, and the display screen will display the
measurement preparation screen one second later. The °F icon will light up,
pull out the protective cover of the infrared thermometer, pull the ear back
and put the detection head of the infrared thermome-ter into the ear canal,
press the „ON/OFF“ to measure, and the measurement result will be pro-mpted
when the measurement is completed.
Note:
- If there are 10 short beeps in a row, the patient‘s temperature may be equal to or higher than 37.5‘C, and he/she may have a fever.
- The ear measurement mode is contact measurement. The inter-val between each measurement is 3-5 seconds. The buzzer emits a short beep before measuring again.
As an Object Thermometer
Press the ON/OFF to start the machine, and the display screen will display the
measurement preparation screen one second later. The °F icon will light up,
press the setting key to switch to the object mode, let the distance between
the infrared thermome-ter and the object be 1cm, press the ON/OFF to measure,
and the measurement result will be prompted when the measure-ment is
completed.
Memory-recall of measurements
This Non-contact Infrared Ther-mometer automatically stores 20 sets
measurements value, the oldest record will be replaced by the latest
measurement value when more than 20 sets.
Read memory record:
Press the „C/°F button during shutdown to enter the memory mode. Each time you
press the °C/°F button, a number (from 1 to 20) will be displayed along with
the symbol, 1 second later, the measurement will be shown, as well as
subsequent measure-ments can be display one after the other by pressing the
°C/°F button each time.
Memory-clear Of Measurements
In the off state, long press the °C/°F button for about 3 seconds, the LED
screen displays CLr, automatically clear all memories, and the buzzer conti-
nuously beeps for 3 times.
APP Operation
Preparation for use
- Tesla Smart is available for both iOS and Android OS. Search the name ‚Tesla Smart‘ in App Store or Android Market or scan the QR-Code to download the App and register or login your account.
- Make sure that the smartphone is connected to the 2.4Ghz network and have Bluetooth & GPS location turned on.
Connect the device
- Open Tesla Smart app and click “+” sign to Add new device
- Select Health care – Tesla Smart Thermometer
- Please follow the instructions to add the Tesla Smart Thermome-ter step by step on your phone
Control the device
- Control thermometer with APP
EXCEPTIONAL SITUATION
Note: We will not be responsible for any quality problem if you do not care and maintain the product as instructed.
CARE AND MAINTENANCE
Care for the main unit
- Keep the unit in the storage case when not in use.
- Clean the unit with a soft dry cloth. Do not use any abrasive or volatile cleaners.
- Never immerse the unit or any of its‘ component in water.
Maintenance
- Do not clean the unit with na-phtha, thinner or gasoline etc.
- Store the unit in a clean and dry location. not subject the unit to extreme hot or cold temperature, humidity, and direct sunlight.
- Remove the batteries if the unit will not be used in 3 months or longer.
- Do not use the unit under the influence of electromagnetic interference (nearby cellphones, microwave etc.)
Note: We will not be responsible for any quality problem if you do not care and maintain the product as instructed.
SPECIFICATION
-
Description: The Infrared Thermometer
-
Display: LED digital display Measuring localization: Forehead, ear canal and object surface Measurement range:
-
Body and ear mode:
89.6°F-109.4°F(32.0°C-43.0°C); Object mode: 32.0°F-199.9°F(0.0°C–100.0°C); -
Temperature unit: °F/°C
-
Display resolution: 0.1°F/0.1°C Accuracy: ±0.4°F/±0.2°C Memory function: 20 sets memory of measurement values
Buzzer function (or voice reading):
-
Turn on the device: 1 Short beep
-
Measurement completed: 1 long beep
-
Fever ≥ 99.5°F or 37.5°C: 10 short beeps
-
3 short beeps when system fails
-
Power source: 3V DC, 2×1.5V AAA alkaline battery (battery is not included)
-
Automatic power-off: In 60±5s
-
Main unit weight: Approx. 58g (batte-ry is not included)
-
Main unit size: L146mm x W37mm x H39mm
-
Battery life: Could be used for 300 times for normal condition
-
Accessory: Instruction manual
-
Operating environment: Body mo-de&ear mode: 50.0°F-104.0°F/10.0°C- – 40.0°C;
-
Object mode: 41.0°F-104.0°F/5°C – 40.0°C;
Relative humidity range ≤85%RH -
Atmospheric pressure range: 70kPa – 106kPa.
-
Storage and shipping environment:
-
Temperature: -4.0°F~+122.0°F/- -20°C~+50°C
-
Humidity: 15%~95%RH; Atmospheric pressure range 70k Pa-106kPa avoid crash, sun bum or rain during transportation.
Clinical Measurement Accuracy and Safety Verification:
The product has passed clinical trials. The measured results of the infrared
forehead thermometer were compared with the measured results of mercury
thermometers, the deviation average
∆tb = 32.02°F not exceeding 32.54°F; the clinical repeatability of the
infrared forehead thermo-meter SR =32.18°F, not exceeding 32.54°F. The
measured results up to the laboratory standard and the clinical standard.
Therefore, the deviation average and the clinical repeatability of the
infrared fore-head thermometer are complied with the regulatory requirement
ISO 80601-2-56. The conclusions are drawn from the clinical trials, the
accuracy and safety are complied with the regulatory requirement.
EMC
IEC 60601-1-2: 2014 Tesla Smart identification, marking and docu-ments for Class B product
Instructions for use
The Tesla Smart is suitable for home healthcare environments and so on.
Warning: Don‘t near active HF surgical equipment and the RF shielded room for
magnetic resonance imaging, where the in-tensity of EM disturbances is high.
Warning: Use of this equipment adjacent to or stacked with other equipment
should be avoided because it could result in improper operation. If such use
is necessary, this equipment and the other equipment should be observed to
verify that they are operating normally.
Warning: Use of accessories, transducers and cables other than those specified
or provided by the manufacturer of this equipment could result in increased
electro-magnetic emissions or decreased electromagnetic immunity of this
equipment and result in improper operation.“
Warning: Portable RF commu-nications equipment (including peripherals such as
antenna cables and external antennas) should be used no closer than 30 cm (12
inches) to any part of the Tesla Smart Thermometer, including cables specified
by the manufacturer. Otherwise, degra-dation of the performance of this
equipment could result.
If any: A list of all cables and maximum lengths of cables (if applicable),
transducers and other ACCESSORIES that are replaceable by the RESPONSI-BLE
ORGANIZATION and that are likely to affect compliance of the Tesla Smart with
the require-ments of Clause 7 (EMISSIONS) and Clause 8 (IMMUNITY). ACCESSORIES
may be specified either generically (e.g. shielded cable, load impedance) or
speci-fically (e.g. by MANUFACTURER and EQUIPMENT OR TYPE REFERENCE).
If any: The performance of the Tesla Smart Thermometer that was determined to
be ESSENTIAL PERFORMANCE and a description of what the OPERATOR can expect if
the ESSENTIAL PERFORMANCE is lost or degraded due to EM DIS-TURBANCES (the
defined term „ESSENTIAL PERFORMANCE“ need not be used).
Technical description
- All necessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to electromagnetic disturbances for the excepted service life.
- Guidance and manufacturer‘s declaration -electromagnetic emissions and Immunity
Guidance and manufacturer‘s declaration – electromagnetic emissions
Emissions test| Compliance
RF emissions CISPR 11
|
Group 1
RF emissions CISPR 11| Class B
Harmonic emissions IEC 61000-3-2|
N/A
Voltage fluctua- tions/ flicker emissions IEC 61000-3-3|
N/A
Electromagnetic Immunity
Immunity Test| IEC 60601-1-2
-Test level
| Compliance level
Electrostatic discharge (ESD)
IEC 61000-4-2
| ±8 kV contact
±2 kV, ±4 kV, ±8 kV,
±15 kV air
| ±8 kV contact
±2 kV, ±4 kV,
±8 kV, ±15
kV air
Electrical fast transient/burst IEC 61000-4-4| Power supply lines
±2 kV
input/output lines
±1 kV
| Not applicable
Surge
IEC 61000-4-5
| line(s) to line(s)±1 kV.; line(s) to earth±2 kV. 100 kHz repetition
frequency| Not applicable
Voltage dips, short
interruptions, and voltage variations on power supply input lines IEC 61000-4-11
| 0% 0.5 cycle; At 0º, 45º, 90º, 135º,
180º, 225º, 270º
and 315º
0% 1 cycle; And 70% 25/30 cycles
Single phase: at 0; 0% 300 cycles
| Not applicable
Power frequency mag- netic field IEC 61000-4-8| 30 A/m
50Hz/60Hz
| 30 A/m
50Hz/60Hz
Conduced RF IEC61000-4-6| 150KHz to 80MHz:
3Vrms, 6Vrms (in ISM and amateur radio bands); 80% Am
at 1kHz
| Not applicable
Radiated RF
-IEC61000-4-3
| 10 V/m; 80 MHz
2,7 GHz; 80 % AM
at 1 kHz
| 10 V/m; 80
MHz 2,7 GHz; 80 % AM at
1 kHz
Guidance and manufacturer’s declaration Electromagnetic Immunity
Radiated RF IEC61000 4 3
(Test speci- fications for ENCLOSU- RE PORT IMMUNITY
to RF wireless commu- nications equipment)
| Test Frequen- cy
(MHz
| Band (MHz)| Service| Modula- tion| Mo- dula- tion (W)| Dis- tan- ce (m)| Im-
muni- ty test Level (V/m)
385| 380-390| TETRA 400| Pulse Modu- lation 18 Hz| 1,8| 0.3| 27
450| 430-470| GMRS 460,
FRS 460
| FM
±5kHz deviati- on 1 kHz sine
| 2| 0.3| 28
710
745
780
| 704-787| LTE Band 13, 17| Pulse modu- lation 217 Hz| 0,2| 0.3| 9
810
870
930
| 800-960| GSM 800/900, TETRA 800,
iDEN 820,
CDMA 850,
LTE Band 5
| Pulse modula- tion
18 Hz
| 2| 0.3| 28
1720
1845
1970
| 1700
-1990
| GSM 1800; CDMA 1900; GSM
1900; DECT; LTE Band1,3,4, 25; UMTS
| Pulse modula- tion
217 Hz
| 2| 0.3| 28
2450| 2400
-2570
| Bluetooth, WLAN, 802.11
b/g/n, RFID 2450, LTE
Band 7
| Pulse modula- tion
217 Hz
| 2| 0.3| 28
5240
5240
5785
| 5100-
5800
| WLAN 802.11
a/n
| Pulse modula- tion
217 Hz
| 0,2| 0.3| 9
INFORMATION ABOUT DISPOSAL AND RECYCLING
This product is marked with the symbol for separate co-llection. The product must be disposed of in accordance with the regulations for disposal of electrical and electro-nic equipment (Directive 2012/19/EU on waste electrical and electronic equipment). Disposal together with regular municipal waste is prohibited. Dispose of all electrical and electronic products in accordance with all local and European regulations at the designated collection points which hold the appropriate authorisation and certification in line with the local and legislative regulations. Correct disposal and recycling help to minimise impacts on the environment and human health. Further information regar-ding disposal can be obtained from the vendor, authorised service centre or local authorities.
EU DECLARATION OF CONFORMITY
Hereby, Shenzhen Urion Technology Limited declares that the radio equipment type UFR102 is in compliance with 2014/53/UE directives. The full text of the EU declaration of conformity is available at the following internet address: tsl.sh/doc
- Connectivity: Bluetooth
- Frequency band: 2.412 – 2.472 MHz
- Max. radio-frequency power (EIRP): < 20 dBm
Manufacturer
Shenzhen Urion Technology Co.,Ltd.
Floor 4-6th of Building D , Jiale Science&Technology Industrial Zone, No.3
ChuangWei Road ,Heshuikou Community,MaTian Street,GuangMing New District,
518106 Shenzhen, PEOPLE‘S REPUBLIC OF CHINA
Tel: (86)-755-29231308
E-mail: urion@urion.com.cn
MADE IN CHINA
Eu representative
Shanghai International Holding Corp. GmbH
(Europe) Eiffestrasse 80, 20537 Hamburg,Germany
Tel: +49-40-2513175
Manufactured for: Tesla Global Limited
www.teslasmart.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>